L3Campus Stackable Managed Switch
「
仕様
- モデル: オマダCampus Stackable L3 Managed Switch
- Front Panel: Mode Selection Button, Management Port, LED,
Console Port USB2.0 Port (Type-C/RJ45), 1G RJ45 Port, 10G SFP+ Slot
導かれた - LEDの徴候:
- PWR1*: Green On (switch powered by PWR1), Off (PWR2
disconnected or not working properly) - PWR2: Green On (switch powered by PWR1 and PWR2 connected),
Yellow On** (PWR2 powered), Off (PWR1 disconnected or not working
ちゃんと) - LED SYS FAN: Green On (all fans work properly), Yellow On (not
all fans work properly) - MGMT: On (device linked to port), Flashing (transmitting or
receiving data), Off (no device linked to port) - MST: On (device linked to port), Flashing (transmitting or
receiving data), Off (no device linked to port)
- PWR1*: Green On (switch powered by PWR1), Off (PWR2
製品使用説明書
第2章: インストール
インストールプロセスを開始する前に、すべてのものがあることを確認してください
the necessary tools and follow safety precautions.
- パッケージ内容: Check all items mentioned in
パッケージ。 - 安全上の注意: ガイドラインに従って
安全な設置を保証します。 - インストールツール: Gather all tools required
インストール用。 - 製品のインストール: ステップバイステップに従ってください
instructions provided in the manual for successful
インストール。
第3章:接続
After installation, connect the switch to the network using
appropriate cables and ports as per your network setup.
第4章:構成
Configure the switch based on your requirements. You can choose
between Standalone Mode or Controller Mode as per your network
ニーズ。
よくある質問
Q: What should I do if the LED indications show an error?
A: If the LED indications suggest improper functioning, check
the power sources and connections. Refer to the troubleshooting
さらにサポートが必要な場合は、マニュアルのセクションを参照してください。
「`
ビジネスネットワーキングソリューション
インストールガイド
オマダCampus Stackable L3 Managed Switch
このインストール ガイドについて
このインストール ガイドでは、ハードウェアの特性、インストール方法、およびインストール中に注意すべき点について説明します。このインストール ガイドは、次の構成になっています。第 1 章 概要 この章では、スイッチの外部コンポーネントについて説明します。第 2 章 インストール この章では、スイッチのインストール方法について説明します。第 3 章 接続 この章では、スイッチの物理的な接続方法について説明します。第 4 章 構成 この章では、スイッチの構成方法について説明します。付録 A トラブルシューティング付録 B 仕様
観客
このインストール ガイドは、次のものを対象としています。
ネットワークエンジニア
ネットワーク管理者
コンベンション
· このガイドに掲載されている一部のモデルは、お住まいの国または地域では販売されていない場合があります。お住まいの地域の販売情報については、https://www.omadanetworks.com/ をご覧ください。
· 第 2 章、第 3 章、および第 4 章の図はデモンストレーションのみを目的としています。実際のスイッチの外観は、図と異なる場合があります。
· PoE 予算の計算は、実験室でのテストに基づいています。実際の PoE 電力予算は保証されておらず、クライアントの制限や環境要因によって変化します。
· このガイドでは、特別なメッセージを強調するために特定の形式を使用します。次の表に、このガイド全体で使用される通知アイコンを示します。
注意することを忘れないでください。 注意は、デバイスの損傷につながる可能性があることを示しています。
注意することを忘れないでください。 このメモには、製品をより適切に使用するために役立つ情報が含まれています。
関連ドキュメント
製品のユーザーガイドとCLIリファレンスガイドは、ダウンロードセンターで提供されています。 最新の製品情報を入手するには、公式にアクセスしてください webサイト: https://support.omadanetworks.com/document/。
コンテンツ
第1章 はじめに ———————- 1
1.1 製品終了view ……………………………………………………..01 1.2 外観………………………………………………………………..01
第2章 インストール ———————- 12
2.1 パッケージの内容 ………………………………………………….12 2.2 安全上の注意 ……………………………………………………..12 2.3 取り付けツール ………………………………………………..14 2.4 製品の取り付け ………………………………………………..14
第3章 接続 ————————— 3
3.1 Ethernet Port …………………………………………………………..22 3.2 10G SFP+/25G SFP28/100G QSFP28 Slot ………..22 3.3 Console Port ……………………………………………………………22 3.4 Verify Installation…………………………………………………….23 3.5 Power On ………………………………………………………………….24 3.6 Initialization………………………………………………………………24 3.7 Stack Topology ……………………………………………………….24
第 4 章 構成 ——————– 27
4.1構成オーバーview………………………………………………27 4.2 スタンドアロンモード……………………………………………………27 4.3 コントローラモード……………………………………………………28
付録A トラブルシューティング —————- 32
付録B 仕様 —————— 33
オマダCampus Stackable L3 Managed Switch
第1章 はじめに
1.1 製品終了view
エンタープライズおよびc向けに設計ampus, Omada Campus Stackable L3 Managed Switch provides wire-speed performance and abundant L2 and L3 management features. It provides a variety of service features and multiple powerful functions with high security. The EIA-standardized framework and smart configuration capacity can provide flexible solutions for a variable scale of networks. Static Routing, RIP, OSPF, BGP, IS-IS, PIM-SM/DM/SSM, and ECMP come with abundant Layer 3 routing protocols that support a scalable network. Physically stacking for builtin redundancy and performance. Redundant power supplies and fans make it an ideal choice for reliable networking architecture. VRRP allows a group of switches to dynamically back up each other. ERPS supports rapid protection and recovery in a ring topology. MACsec, secure boot, ACL, 802.1x and Dynamic ARP Inspection provide robust security strategies. QoS and IGMP snooping/filtering optimize voice and video application. Link aggregation (LACP) increases aggregated bandwidth, optimizing the transport of business critical data. SNMP, RMON, WEB, Netconf and CLI Log-in bring abundant management policies. These switches integrate multiple functions with excellent performance, and is friendly to manage, which can fully meet the need of the users demanding higher networking performance. S6500-24GP4XF/S6500-48GP6XF/S6500-24MPP4Y/S6500-48MPP6Y is also a Power Sourcing Equipment (PSE*). The RJ45 ports that support Power over Ethernet (PoE*) function can automatically detect and supply power to those powered devices (PDs*) complying with IEEE 802.3af, IEEE 802.3at, and IEEE 802.3bt (only for S6500-24MPP4Y/S6500-48MPP6Y). *PSE: a device (switch or hub for instance) that provides power through an Ethernet cable. *PoE: This technology describes a system to transmit electrical power, along with data, to remote devices over standard twisted-pair cable in an Ethernet. *PD: a device powered by a PSE and thus consumes energy. Exampファイルには、ネットワーク カメラ、無線 LAN アクセス ポイント、IP 電話、ネットワーク ハブ、組み込みコンピュータなどへの電力供給が含まれます。
1.2 外観
Front Panel (The figure is for demonstration only. It may differ from your actual product. )
The front panel of S6500-24G4XF is shown as the following figure.
モード選択ボタン
管理ポート
導かれた
Console Port USB2.0 Port (Type-C/RJ45)
1G RJ45ポート
10G SFP+ Slot LED
The front panel of S6500-48G6XF is shown as the following figure.
モード選択ボタン
管理ポート
導かれた
Console Port USB2.0 Port (Type-C/RJ45)
1G RJ45ポート
10G SFP+ Slot LED
はじめに 01
オマダCampus Stackable L3 Managed Switch
LED表示
PWR1 *
PWR2
グリーンオン
オフ
グリーンオン
黄色点灯**
オフ
グリーンオン
オフ
オフ
表示
スイッチは PWR1 によって電源供給されます。PWR2 が切断されているか、正しく動作していません。
スイッチは PWR1 から電力を供給されます。 PWR1とPWR2が接続されています。*
スイッチは PWR2 によって電源供給されます。PWR1 が切断されているか、正しく動作していません。
スイッチの電源がオフになっているか、PWR1 と PWR2 の両方が正しく動作していません。
LED SYS FAN
管理
月曜日
Port 1-24 of S6500-24G4XF/ Port 1-48 of S6500-48G6XF
(When the SPEED LED is on)
Port 1-24 of S6500-24G4XF/ Port 1-48 of S6500-48G6XF
(STK LEDが点灯している場合)
Port 25-28 of S6500-24G4XF/ Port 49-54 of S6500-48G6XF ***
表示
点滅: スイッチは正常に動作しています。オンまたはオフ: スイッチは正常に動作していません。
緑色点灯: すべてのファンが正常に動作しています。 黄色点灯: すべてのファンが正常に動作していません。
On: A device is linked to the port. Flashing: Transmitting or receiving data. Off: No device is linked to the port.
On: The device functions as the master switch in the stack topology or it works individually. Off: The device functions as the member switch in the stack topology.
緑色点灯: 1000 Mbps で動作していますが、アクティビティはありません。緑色点滅: 1000 Mbps で動作しており、データを送信または受信しています。黄色点灯: 10Mbps/100 Mbps で動作していますが、アクティビティはありません。黄色点滅: 10Mbps/100 Mbps で動作しており、データを送信または受信しています。消灯: 対応するポートにデバイスがリンクされていません。
オン: ポート番号はスタック トポロジ内のユニット ID を示します。
緑色点灯: 10 Gbps で動作していますが、アクティビティはありません。緑色点滅: 10 Gbps で動作しており、データを送信または受信しています。黄色点灯: 1 Gbps で動作していますが、アクティビティはありません。黄色点滅: 1 Gbps で動作しており、データを送信または受信しています。消灯: 対応するポートにデバイスがリンクされていません。
*PWR1 is the primary power supply and it takes priority over PWR2. When the device is powered by PWR1, PWR2 will be working in the backup mode.
**PWR1 と PWR2 の両方が正常に動作し、スイッチが PWR1 によって電源供給されている場合、PWR10 を抜いてから LED PWR20 (黄色) が消えるまでに 2 ~ 2 秒かかります。
***All 10 Gbps SFP+ slots can be used as uplink ports or stacking ports. When used as stacking ports, the slots need to run at the highest speed.
02 はじめに
オマダCampus Stackable L3 Managed Switch The front panel of S6500-24GP4XF is shown as the following figure.
モード選択ボタン
管理ポート
LED Console Port USB2.0 Port (Type-C/RJ45)
1G RJ45ポート
10G SFP+ Slot LED
S6500-48GP6XF のフロント パネルは次の図に示されています。
モード選択ボタン
管理ポート
LED Console Port USB2.0 Port (Type-C/RJ45)
1G RJ45ポート
10G SFP+ Slot LED
The front panel of S6500-24M4Y is shown as the following figure.
モード選択ボタン
管理ポート
LED Console Port USB2.0 Port (Type-C/RJ45)
2.5G RJ45ポート
25G SFP28 Slot LED
The front panel of S6500-24MPP4Y is shown as the following figure.
モード選択ボタン
管理ポート
LED Console Port USB2.0 Port (Type-C/RJ45)
2.5G RJ45ポート
25G SFP28 Slot LED
はじめに 03
オマダCampus Stackable L3 Managed Switch The front panel of S6500-48M6Y is shown as the following figure.
モード選択ボタン
管理ポート
LED Console Port USB2.0 Port (Type-C/RJ45)
2.5G RJ45ポート
The front panel of S6500-48MPP6Y is shown as the following figure.
25G SFP28 Slot LED
モード選択ボタン
管理ポート
LED Console Port USB2.0 Port (Type-C/RJ45)
2.5G RJ45ポート
25G SFP28 Slot LED
LED Indication LED
PWR1* PWR2
SYS FAN PoE MAX
(For S6500-24GP4XF, S6500-48GP6XF, S6500-24MPP4Y, S6500-48MPP6Y)
管理
月曜日
表示
Green On: The power supply works properly. Green Flashing: The power supply module is not plugged in properly or not compatible with the switch. Yellow On: The power supply works properly but the switch is powered by the other power supply.** Yellow Flashing: The power supply module is plugged in properly but there’s is no AC power input; abnormal power supply. Off: No power supply module is inserted.
点滅: スイッチは正常に動作しています。オンまたはオフ: スイッチは正常に動作していません。
緑色点灯: すべてのファンが正常に動作しています。 黄色点灯: すべてのファンが正常に動作していません。
点灯: 残りの PoE 電力は 7 W です。点滅: この LED が 7 分間点灯した後も、残りの PoE 電力は 2 W を維持します。消灯: 残りの PoE 電力は 7 W を超えています。
On: A device is linked to the port. Flashing: Transmitting or receiving data. Off: No device is linked to the port.
On: The device functions as the master switch in the stack topology or it works individually. Off: The device functions as the member switch in the stack topology.
04 はじめに
オマダCampus Stackable L3 Managed Switch
導かれた
表示
Port 1-24 of S6500-24GP4XF/
Port 1-48 of S6500-48GP6XF
(When the SPEED LED is on)
緑色点灯: 1000 Mbps で動作していますが、アクティビティはありません。緑色点滅: 1000 Mbps で動作しており、データを送信または受信しています。黄色点灯: 10Mbps/100 Mbps で動作していますが、アクティビティはありません。黄色点滅: 10Mbps/100 Mbps で動作しており、データを送信または受信しています。消灯: 対応するポートにデバイスがリンクされていません。
Port 1-24 of S6500-24M4Y & S6500-24MPP4Y/
Port 1-48 of S6500-48M6Y & S6500-48MPP6Y
(When the SPEED LED is on)
Green On: Running at 2.5 Gbps, but no activity. Green Flashing: Running at 2.5 Gbps and transmitting or receiving data. Yellow On: Running at 10 Mbps/100 Mbps/1000 Mbps, but no activity. Yellow Flashing: Running at 10 Mbps/100 Mbps/1000 Mbps and transmitting or receiving data. Off: No device is linked to the corresponding port.
Port 1-24 of S6500-24GP4XF, S6500-24M4Y &
S6500-24MPP4Y/
Port 1-48 of S6500-48GP6XF, S6500-48M6Y &
S6500-48MPP6Y
(STK LEDが点灯している場合)
オン: ポート番号はスタック トポロジ内のユニット ID を示します。
Port 1-24 of S6500-24GP4XF & S6500-24MPP4Y/
Port 1-48 of S6500-48GP6XF & S6500-48MPP6Y
(PoE LED点灯時)
Green On: The port is supplying power normally. Green Flashing: The supply power exceeds the correponding port’s maximum power. Yellow On: Overload or short circuit is detected. Off: Not providing PoE power on the port
Port 25-28 of S6500-24GP4XF/ Port 49-54 of S6500-48GP6XF ***
緑色点灯: 10 Gbps で動作していますが、アクティビティはありません。緑色点滅: 10 Gbps で動作しており、データを送信または受信しています。黄色点灯: 1 Gbps で動作していますが、アクティビティはありません。黄色点滅: 1 Gbps で動作しており、データを送信または受信しています。消灯: 対応するポートにデバイスがリンクされていません。
Port 25-28 of S6500-24M4Y & S6500-24MPP4Y/
Port 49-54 of S6500-48M6Y & S6500-48MPP6Y***
Green On: Running at 25 Gbps, but no activity. Green Flashing: Running at 25 Gbps and transmitting or receiving data. Yellow On: Running at 1 Gbps/10 Gbps, but no activity. Yellow Flashing: Running at 1 Gbps/10 Gbps and transmitting or receiving data. Off: No device is linked to the corresponding port.
*By default, S6500-24GP4XF is shipped with a PSM500-AC power supply module, S6500-24M4Y/S650048M6Y is shipped with a PSM550-AC power supply module, and S6500-48GP6XF/S6500-24MPP4Y/ S6500-48MPP6Y is shipped with a PSM900-AC power supply module. One more power supply module needs to be purchased separately.
**By default, both PWR1 and PWR2 will work simultaneously in the load sharing mode. They can also work simultaneously in the redundant power supply mode: for S6500-24GP4XF/S6500-48GP6XF/S650024MPP4Y/S6500-48MPP6Y, you can specify the primary power supply and the backup power supply according to your needs; for S6500-24M4Y/S6500-48M6Y, you can only set PWR1 as the primary power supply and PWR2 as the backup power supply. Generally, the primary power supply takes priority over the backup power supply.
***All 10 Gbps SFP+ slots and 25 Gbps SFP28 slots can be used as uplink ports or stacking ports. When used as stacking ports, the slots need to run at the highest speed.
はじめに 05
オマダCampus Stackable L3 Managed Switch The front panel of S7500-26XF6Y is shown as the following figure.
管理ポート
導かれた
Console Port USB3.0 Port
(RJ45/Type-C)
モード選択
ボタン
10G SFP+ Slot (Port 1-26)
The front panel of S7500-48XF4C is shown as the following figure.
LED 25G SFP28 Slot (Port 27-32)
モード選択ボタン
管理ポート
LED Console Port USB3.0 Port (Type-C/RJ45)
10G SFP+ Slot (Port 1-48)
The front panel of S7500-24Y4C is shown as the following figure.
100G QSFP28 Slot LED (Port 49-52)
管理ポート
導かれた
USB3.0ポート
コンソールポート
(RJ45/Type-C)
モード選択ボタン
25G SFP28スロット
導かれた
(ポート1-24)
The front panel of S7500-48Y8C is shown as the following figure.
100G QSFP28 Slot (Port 25-28)
LED Mode Selection Button
25G SFP28 Slot (Port 1-48)
06 はじめに
100G QSFP28 Slot (Port 49-56)
オマダCampus Stackable L3 Managed Switch The front panel of S7500-32C is shown as the following figure.
モード選択ボタン
管理ポート LED
USB3.0ポート
Console Port (Type-C/RJ45)
100G QSFP28スロット
導かれた
Note: S7500-24Y4C and S7500-48Y8C are designed for installation in Network Telecommunications Facilities (NTFs) where ambient temperature and humidity are controlled.
LED Indication LED
PWR1* PWR2
システムファン
管理
月曜日
Port 1-26 of S7500-26XF6Y/ Port 1-48 of S7500-48XF4C
(SPD LEDが点灯している場合)
Port 1-24 of S7500-24Y4C/ Port 1-48 of S7500-48Y8C
(When the SPD/SPEED LED is on)
表示
Green On: The power supply works properly. Green Flashing: The power supply module is not plugged in properly or not compatible with the switch. Yellow On: The power supply works properly but the switch is powered by the other power supply.** Yellow Flashing: The power supply module is plugged in properly but there’s is no AC power input; abnormal power supply. Off: No power supply module is inserted.
点滅: スイッチは正常に動作しています。オンまたはオフ: スイッチは正常に動作していません。
緑: すべてのファンが正常に動作しています。 黄色: すべてのファンが正常に動作しているわけではありません。
On: A device is linked to the port. Flashing: Transmitting or receiving data. Off: No device is linked to the port.
注記:
For S7500-48Y8C, this LED lights green at 1 Gbps and orange at sub-1 Gbps.
On: The device functions as the master switch in the stack topology or it works individually. Off: The device functions as the member switch in the stack topology.
緑色点灯: 10 Gbps で動作していますが、アクティビティはありません。緑色点滅: 10 Gbps で動作しており、データを送信または受信しています。黄色点灯: 1 Gbps で動作していますが、アクティビティはありません。黄色点滅: 1 Gbps で動作しており、データを送信または受信しています。消灯: 対応するポートにデバイスがリンクされていません。
Green On: Running at 25 Gbps, but no activity. Green Flashing: Running at 25 Gbps and transmitting or receiving data. Yellow On: Running at 1 Gbps/10 Gbps, but no activity. Yellow Flashing: Running at 1 Gbps/10 Gbps and transmitting or receiving data. Off: No device is linked to the corresponding port.
はじめに 07
オマダCampus Stackable L3 Managed Switch
導かれた
表示
Port 27-32 of S7500-26XF6Y ***
(SPD LEDが点灯している場合)
Green On: Running at 25 Gbps, but no activity. Green Flashing: Running at 25 Gbps and transmitting or receiving data. Yellow On: Running at 1 Gbps/10 Gbps, but no activity. Yellow Flashing: Running at 1 Gbps/10 Gbps and transmitting or receiving data. Off: No device is linked to the corresponding port.
Port 49-52 of S7500-48XF4C/
Port 25-28 of S7500-24Y4C/ Port 49-56 of S7500-48Y8C/ Port 1-32 of S7500-32C***
(When the SPD/SPEED LED is on)
緑色点灯: 100 Gbps で動作していますが、アクティビティはありません。緑色点滅: 100 Gbps で動作しており、データを送信または受信しています。黄色点灯: 40 Gbps で動作していますが、アクティビティはありません。黄色点滅: 40 Gbps で動作しており、データを送信または受信しています。消灯: 対応するポートにデバイスがリンクされていません。
注記:
For S7500-48XF4C/S7500-48Y8C/S7500-32C, the indication above applies only when the 100 Gbps QSFP28 slots work with common cables. When the slots work with 1-to-4 breakout cables, a single slot is split into four 25 Gbps interfaces. In such scenario, the LED will light green only when all four interfaces are working at 25 Gbps (maximum speed), otherwise it will light yellow. When no device is connected to any of the four interfaces, the LED will be off. (The 100 Gbps QSFP28 slots will support 1-to-4 breakout cables in a future software release.)
Port 1-32 of S7500-26XF6Y/
Port 1-48 of S7500-48XF4C/ Port 1-28 of S7500-24Y4C/ Port 1-56 of S7500-48Y8C
(STK LEDが点灯している場合)
オン: ポート番号はスタック トポロジ内のユニット ID を示します。
*By default, S7500-26XF6Y/S7500-48XF4C/S7500-24Y4C/S7500-48Y8C/S7500-32C is shipped with a PSM550-AC power supply module installed respectively. One more power supply module needs to be purchased separately. **By default, both PWR1 and PWR2 will work simultaneously in the load sharing mode. They can also work simultaneously in the redundant power supply mode with PWR1 as the primary power supply and PWR2 as the backup power supply. Generally, the primary power supply takes priority over the backup power supply. ***All 25 Gbps SFP28 slots of S7500-26XF6Y and 100 Gbps QSFP28 slots of S7500-48XF4C/S7500-24Y4C/ S7500-48Y8C/S7500-32C can be used as uplink ports or stacking ports. When used as stacking ports, the slots need to run at the highest speed.
Port Introduction (The Management Port, Console Ports, and USB Ports of S7500-48Y8C are located on the rear panel.)
Management Port Designed to connnect the device for management through web, CLI or SNMP. Do not connect this port to any outdoor device, as this may induce surge and lightning damage. Console Port Designed to connect with a computer for monitoring and configuring the switch. When the switch has an RJ45 console port and a Type-C console port, console input is active on only one console port at a time. By default, the Type-C connector takes priority over the RJ45 connector, or you can change the priority through the web. Do not connect this port to any outdoor device, as this may induce surge and lightning damage. USB Port Designed to install the USB flash disk for data storage. 1000M RJ45 Port Designed to connect to the device with a bandwidth of 10Mbps, 100 Mbps or 1000 Mbps. For PoE switches, the port can also provide power for PDs.
08 はじめに
オマダCampus Stackable L3 Managed Switch
2.5G RJ45 Port Designed to connect to the device with a bandwidth of 10 Mbps, 100 Mbps, 1000 Mbps or 2.5 Gbps. For PoE switches, the port can also provide power for PDs. 10G SFP+ Slot Designed to install the 10 Gbps/1 Gbps optical module. 25G SFP28 Slot Designed to install the 25 Gbps/10 Gbps/1 Gbps optical module. 100G QSFP28 Slot Designed to install the 100 Gbps/40 Gbps optical module. Port Feature
モデル
1000メートル
2.5G 10G SFP+ 25G SFP28 100G QSFP28 Management Console USB
RJ45 Port RJ45 Port Slot
スロット
スロット
ポート
ポート ポート
S6500-24G4XF
24
/
4
/
/
S6500-48G6XF
48
/
6
/
/
S6500-24GP4XF
24
/
4
/
/
S6500-48GP6XF
48
/
6
/
/
S6500-24M4Y
/
24
/
4
/
S6500-24MPP4Y
/
24
/
4
/
S6500-48M6Y
/
48
/
6
/
S6500-48MPP6Y
/
48
/
6
/
S7500-26XF6Y
/
/
26
6
/
S7500-48XF4C
/
/
48
/
4
S7500-24Y4C
/
/
/
24
4
S7500-48Y8C
/
/
/
48
8
S7500-32C
/
/
/
/
32
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
Rear Panel (The figure is for demonstration only. It may differ from your actual product. )
The rear panel of S6500-24G4XF/S6500-48G6XF is shown as the following figure. The figure is for demonstration purposes only. Your switch may differ in appearance from the depicted.
Kensington Security Slot Grounding Terminal Power Socket
Locking Strap Slot
注意: PWR1 はプライマリ電源であり、PWR2 よりも優先されます。
はじめに 09
オマダCampus Stackable L3 Managed Switch
The rear panel of S6500-24GP4XF/S6500-48GP6XF/S6500-24MPP4Y/S6500-48MPP6Y is shown as the following figure. The figure is for demonstration purposes only. Your switch may differ in appearance from the depicted.
ケンジントン セキュリティ スロット
導かれた
接地端子
電源モジュール
導かれた
Locking Strap Slot
Note: By default, S6500-24GP4XF is shipped with a PSM500-AC power supply module, and S650048GP6XF/S6500-24MPP4Y/S6500-48MPP6Y is shipped with a PSM900-AC power supply module. One more power supply module needs to be purchased separately. Both PWR 1 and PWR2 can work simultaneously, or you can specify the primary power supply and the backup power supply according to your needs. Generally, the primary power supply takes priority over the backup power supply.
The rear panel of S6500-24M4Y/S6500-48M6Y/S7500-26XF6Y/S7500-48XF4C/S7500-24Y4C is shown as the following figure. The figure is for demonstration purposes only. Your switch may differ in appearance from the depicted.
接地端子
導かれた
Power Supply Module Locking Strap Slot
導かれた
ケンジントン セキュリティ スロット
Note: By default, the device is shipped with a PSM550-AC power supply module installed. One more power supply module needs to be purchased separately. When the switch has two power supply modules installed, both PWR1 and PWR2 will work simultaneously in the load sharing mode by default. They can also work simultaneously in the redundant power supply mode: for S6500-24M4Y/S6500-48M6Y, you can only set PWR1 as the primary power supply and PWR2 as the backup power supply; for S7500-26XF6Y/S7500-48XF4C/S7500-24Y4C, you can specify the primary power supply and the backup power supply according to your needs; Generally, the primary power supply takes priority over the backup power supply.
S7500-48Y8Cの背面パネルは下図の通りです。この図は説明のみを目的としており、実際のスイッチの外観は図と異なる場合があります。
接地端子
導かれた
導かれた
ロッキングストラップ
スロット
電源モジュール
10 はじめに
ManagemeC(nTtoyPnposeor-tCle/RPJoU4rt5S)B3P.o0wPeorrSt upplyLoMcokdiSnulgoletStraLpED
オマダCampus Stackable L3 Managed Switch
Note: By default, the device is shipped with a PSM550-AC power supply module installed. One more power supply module needs to be purchased separately. When the switch has two power supply modules installed, both PWR1 and PWR2 will work simultaneously in the load sharing mode by default. They can also work simultaneously in the redundant power supply mode with PWR1 as the primary power supply and PWR2 as the backup power supply. Generally, the primary power supply takes priority over the backup power supply.
The rear panel of S7500-32C is shown as the following figure. The figure is for demonstration purposes only. Your switch may differ in appearance from the depicted.
LED LED
Locking Strap Slot
Power Supply Module Kensington Security Slot
接地端子
導かれた
Locking Strap Slot
電源モジュール
Note: By default, the device is shipped with a PSM550-AC power supply module installed. One more power supply module needs to be purchased separately. When the switch has two power supply modules installed, both PWR1 and PWR2 will work simultaneously in the load sharing mode by default. They can also work simultaneously in the redundant power supply mode with PWR1 as the primary power supply and PWR2 as the backup power supply. Generally, the primary power supply takes priority over the backup power supply.
Power Supply Module The pluggable power supply module PSM500-AC/PSM900-AC/PSM550-AC is an AC-input power supply module. It can convert the input voltage to 53.5 V (12 V for PSM550-AC) with the maximum output power of 500 W/900 W/550 W respectively. Kensington Security Slot Secure the lock (not provided) into the security slot to prevent the device from being stolen.
Grounding Terminal The switch already comes with lightning protection mechanism. You can also ground the switch through the PE (Protecting Earth) cable of AC cord or with Ground Cable. For detailed lightning protection measures, refer to the Lightning Protection Guide from: https://support.omadanetworks.com/r/1004/. Locking Strap Slot Remove the instruction label and insert the AC power cable locking strap into the slot to secure the power cable.
はじめに 11
オマダCampus Stackable L3 Managed Switch
第2章 インストール
2.1 パッケージ内容
以下のものが同梱されていることを確認してください。 リストされたアイテムのいずれかが破損または欠落している場合は、販売店にお問い合わせください。 図はデモンストレーションのみを目的としています。 実際の商品は、表示されているものと外観や数量が異なる場合があります。
スイッチ
電源コードとコンソールケーブル
インストールガイド
ビジネスネットワーキングソリューション
インストールガイド
オマダCampus Stackable L3 Managed Switch
取り付けブラケット、ネジ、ゴム足
2.2 安全上の注意
不適切な使用によるデバイスの損傷や身体への傷害を避けるために、以下の規則を遵守する必要があります。
安全上の注意 取り付け中は電源を切ってください。静電気防止用リストストラップを着用し、リストストラップが肌にしっかりと接触し、
しっかりと接地してください。スイッチに付属の電源コードのみを使用してください。電源電圧がtageは、背面パネルに表示されている仕様と一致します。
スイッチは換気の良い場所に設置し、通気口が塞がれていないことを確認してください。
ブロックされています。スイッチのカバーを開けたり取り外したりしないでください。デバイスを清掃する前に、電源を切ってください。水っぽい布で拭いたり、絶対に
use any other liquid cleaning method. Place the device with its bottom surface facing downwards. Only instructed person or skilled person can be allowed to install, replace, or service this device.
サイト要件
温度/湿度
12 インストール
オマダCampus Stackable L3 Managed Switch Keep the equipment room at an appropriate level of temperature and humidity. Too much or too little humidity may lead to bad insulation, leakage of electricity, mechanical property changes, and corrosion. High temperatures may accelerate aging of the insulation materials, significantly shortening the service life of the device. To find out the best temperature and humidity conditions for the device, check the Appendix B Specifications. Clearness
スイッチに蓄積したほこりは静電気によって吸収され、金属接点の接触不良を引き起こす可能性があります。デバイスには静電気を防止するためのいくつかの対策が講じられていますが、静電気の強さが強すぎると、内部の回路基板上の電子部品に致命的な損傷を与える可能性があります。スイッチの動作に対する静電気の影響を回避するには、次の点に特に注意してください。デバイスを定期的にほこり取りし、室内の空気を清潔に保ちます。デバイスをしっかりと接地し、静電気を確実に伝達します。電磁干渉
機器の静電容量やインダクタンスなどの電子部品は、静電容量結合、インダクタンス結合、インピーダンス結合による伝導放射などの外部干渉の影響を受ける可能性があります。干渉を減らすには、次の対策を講じてください。電力網からの干渉を効果的にフィルタリングできる電源を使用してください。無線送信機などの高周波および大電流デバイスから機器を遠ざけてください。
必要に応じて電磁シールドを使用してください。雷保護
インストール 13
オマダCampus Stackable L3 Managed Switch
非常に高いボリュームtag雷が発生すると瞬時に電流が発生し、放電経路内の空気が瞬時に20,000℃まで加熱されます。この瞬間電流は電子機器に損傷を与えるほど強いため、より効果的な避雷対策を講じる必要があります。ラックとデバイスが適切に接地されていることを確認してください。電源ソケットが地面にしっかりと接触していることを確認してください。合理的なケーブル配線システムを維持し、誘導雷を避けてください。屋外配線の場合は信号用SPD(サージ保護装置)をご使用ください。
注:雷保護対策の詳細については、https://support.omadanetworks.com/r/1004/ の雷保護ガイドを参照してください。設置場所
When installing the device on a rack or a flat workbench, attach much importance to the following items: Install the device with its bottom surface facing down only. This equipment is not suitable for use in locations where children are likely to be present. The rack or workbench is flat, stable, and sturdy enough to support the weight of 9.5 kg at least. The rack or workbench has a good ventilation system. The equipment room is well ventilated. The rack is well grounded. Keep the device less than 1.5 meters away from the power socket.
2.3 インストールツール
プラスドライバーESD防止リストラップケーブル
注: これらのツールは当社の製品には含まれていません。必要に応じて、個別に購入できます。
2.4 製品のインストール
スイッチは前後方向の放熱機能を備えて設計されています。作動時には、下図のように空気が循環します。放熱効果を高めるために、デバイスを風通しの良い環境に設置し、デバイスの周囲に 5 ~ 10 cm の隙間を空けてください。
14 インストール
図2-1
空気循環
オマダCampus Stackable L3 Managed Switch
デスクトップインストール
デバイスをデスクトップにインストールするには、次の手順に従います。
1.すべてのフィッティングでデバイスの全重量を支えるのに十分な強度のある平らな面にデバイスを置きます。
2. ゴム足から粘着性の裏紙をはがします。
3. デスクトップに置いたときに滑らないように、デバイスの底面にゴム足を取り付けます。
図2-2
デスクトップインストール
デバイスの足の下部のノッチ
ラックの設置
パッケージには 6 組の異なるラックマウント ブラケットが含まれており、その写真は下に示すものであり、実際の製品とは異なる場合があります。
図2-3
取り付けブラケット
Screw Hole Group 2
Bracket D Bracket C Bracket B Bracket A
Screw Hole Group 1
Screw Hole Group 3
ブラケットF
Screw Hole Group 4-2 (for device with 420mm depth)
Screw Hole Group 5
ねじ穴
グループ4-1
Screw Hole Group 4-3
(for device with 380mm depth)
(for device with
460mm depth)
括弧E
インストール 15
オマダCampus Stackable L3 Managed Switch
Before installing the device in an EIA standard-sized, 19-inch rack, please check the efficiency of the grounding system and the stability of the rack, then wear an ESD-preventive wrist strap, and make sure that it has good skin contact and is well grounded. Bracket B, C & E have two adjustable ears, please measure the distance between the front-post rack and the rear-post rack, and determine a suitable mounting method from below:
方法
デモンストレーション
Front: Bracket A Rear: Bracket D (Screw Hole Group 1) + Bracket B (Ear towards back)
Rack Distance
(For device with a depth of 380mm)
Rack Distance
(For device with a depth of 420mm)
Rack Distance
(For device with a depth of 460mm)
498-640mm 538-680mm 578-720mm
Front: Bracket A Rear: Bracket D (Screw Hole Group 1) + Bracket C (Ear towards back)
477-498mm 517-538mm 557-578mm
Front: Bracket A Rear: Bracket D (Screw Hole Group 2) + Bracket C (Ear towards back)
429-477mm 469-517mm 509-557mm
Front: Bracket A Rear: Bracket D (Screw Hole Group 2) + Bracket C (Ear towards front)
410-429mm 450-469mm 490-509mm
Front: Bracket A Rear: Bracket D (Screw Hole Group 3) + Bracket C (Ear towards back)
357-410mm 397-450mm 437-490mm
Front: Bracket A Rear: Bracket D (Screw Hole Group 2) + Bracket B (Ear towards back)
282-410mm 322-450mm 362-490mm
16 インストール
オマダCampus Stackable L3 Managed Switch
Front: Bracket A Rear: Bracket F (Screw Hole Group 4) + Bracket E (Ear towards back)
555-936mm 555-936mm 555-936mm
Front: Bracket A Rear: Bracket F (Screw Hole Group 5) + Bracket E (Ear towards back)
743-1121mm 743-1121mm 743-1121mm
デバイスをインストールするには、以下の手順に従ってください。
1. Attach the M6 nuts to the racks.
図2-4
Securing M6 Nuts
×8
2. Attach the mounting brackets (B, C or E) to the rear-post racks and secure them with the provided M6 screws, as illustrated in the following figure.
図2-5
Installing Brackets on Racks
or
3. Attach the brackets A & D/F to the switch with the provided M3 screws.
インストール 17
オマダCampus Stackable L3 Managed Switch
図2-6
Installing Brackets on Switch
4. After the brackets are attached to the device, hold the switch with attached brackets up until it aligns with the brackets on the racks, and gently push the switch backwards until it is in place, then secure the device on the racks with M6 screws and fix brackets B/C or E to brackets D or F with M4 screws on both sides.
図2-7
Installing Switch on Racks
Caution: Leave 5 to 10 cm gaps around the devices for air circulation. Avoid placing heavy things on the device. Mount devices in the order demonstrated above and ensure a certain clearance between devices for
the purpose of heat dissipation.
18 インストール
オマダCampus Stackable L3 Managed Switch
電源モジュールの取り付け
S6500-24GP4XF is shipped with a PSM500-AC power supply module installed, S6500-48GP6XF/ S6500-24MPP4Y/S6500-48MPP6Y is shipped with a PSM900-AC power supply module installed, and S6500-24M4Y/S6500-48M6Y/S7500-26XF6Y/S7500-48XF4C/S7500-24Y4C/S7500-48Y8C/S750032C is shipped with a PSM550-AC power supply module installed. It looks like below, and the image may differ from your actual product.
図2-8
Appearance of the Power Supply Module
AC 電源コード コネクタ
FAN
リテーナークリップ
Extraction Handle
導かれた
Locking Strap Slot Release Handle
電源モジュールをもう 1 つ追加する必要がある場合は、次の手順に従ってください。
1. Wear an ESD-preventive wrist strap, and make sure that it has good skin contact and is well grounded.
2. Press the extraction handle of the module with one hand, and hold the bottom of the module using your other hand. Gently push the module in along the slot guide rail.
3. Release the extraction handle to fix the power supply module in place.
図2-9
電源モジュールの取り付け
リリースハンドル
Caution: Do not plug the power cord until the power supply module installation is completed. When installing a power supply module, make sure it is set correctly in the operation of installation. Do not use too much force in the installation. If resistance is encountered or positions of the power
supply module appear larger during installation, you must first remove the module and then reinstall the module. If the Retainer Clips cannot spring up naturally and the power module is blocked, it may be due to the power supply module is not installed properly. Please check carefully.
The power supply module is designed with a locking strap slot. If you need to secure the power cable with the included locking strap, please follow the steps:
1. Wear an ESD-preventive wrist strap, and make sure that it has good skin contact and is well grounded.
インストール 19
オマダCampus Stackable L3 Managed Switch
2. Remove the instruction label on the AC power cable locking strap slot. 3. Attach the clamp to the AC power cable and insert the locking strap into the slot. 4. Adjust tightness and distance of the locking strap using clips to ensure the cable is securely fastened.
Figure 2-10 Installing the Locking Strap
電源モジュールを取り外す必要がある場合は、次の手順に従ってください。
1. Wear an ESD-preventive wrist strap, and make sure that it has good skin contact and is well grounded.
2. Depress the retainer clip to release the locking strap, and then remove the power cord from the external power supply system and the power module.
3. Press the extraction handle of the module with one hand, and pull the extraction handle using your other hand, until the module completely comes out of the chassis.
Caution: Unplug the power cord first, then remove the power supply module. When removing a power supply module, make sure that the power supply module is set correctly in the
operation of installation. In order to better protect the power supply module during removal, it is recommended that you
package it in an antistatic bag.
ファンモジュールの取り付け
S6500-24GP4XF/S6500-48GP6XF/S6500-24M4Y/S6500-24MPP4Y/S6500-48M6Y/S650048MPP6Y/S7500-26XF6Y/S7500-48XF4C/S7500-24Y4C/S7500-48Y8C/S7500-32C is shipped with hot-swappable fan modules installed. They look like below, and the images may differ from your actual product.
図2-11 ファンモジュールの外観
導かれた
20 インストール
Extraction Handle Retainer Clips Release Handle
オマダCampus Stackable L3 Managed Switch For normal operation of the switch, please ensure that models with 5 fan modules maintain at least 4 operational modules, while models with 4 fan modules maintain at least 3 operational modules. If one fan module is damaged, please replace it as follows: 1. Wear an ESD-preventive wrist strap, and make sure that it has good skin contact and is well
grounded. 2. Press the extraction handle of the module with one hand, and pull the extraction handle until the
module completely comes out of the chassis.
図2-12 損傷したファンモジュールの取り外し
3. Press the extraction handle of a new fan module with one hand, and hold the bottom of the module using your other hand. Gently push the module in along the slot guide rail.
4. Release the extraction handle to fix the power supply module in place. Caution: S6500-24GP4XF/S6500-48GP6XF/S6500-24M4Y/S6500-24MPP4Y/S6500-48M6Y/S6500-48MPP6Y/ S7500-26XF6Y uses hot-swappable fan modules with a maximum speed of 9,000 RPM. S7500-48XF4C/ S7500-24Y4C/S7500-48Y8C/S7500-32C uses hot-swappable fan modules with a maximum speed of 18,000 RPM. Please do not interchange or mix fan modules between models. Sharp edges on the fan module may cause injury, so please operate with caution. Make sure the damaged fan module is in place before you are going to replace it. DO NOT unplug the damaged fan module until the replacement operation. Do not use too much force in the replacement. If resistance is encountered or positions of the fan module appear larger during installation, you must first remove the module and then reinstall the module. If the Retainer Clips cannot spring up naturally and the power module is blocked, it may be due to the fan module is not installed properly. Please check carefully.
インストール 21
オマダCampus Stackable L3 Managed Switch
第3章 接続
3.1 イーサネットポート
次の図に示すように、スイッチのイーサネット ポートを RJ45 ケーブルでコンピュータに接続します。
図3-1
RJ45ポートの接続
RJ45ポート
RJ45ケーブル
3.2 10G SFP+/25G SFP28/100G QSFP28 Slot
The following figure demonstrates the connection of 10G SFP+/25G SFP28/100G QSFP28 slot to an optical module
図3-2
Inserting the Fiber Module
Slot Fiber Module
3.3コンソールポート
CLI (コマンド ライン インターフェイス) を使用するとスイッチを管理できるため、ケーブルを介して PC または端末をスイッチのコンソール ポートに接続した後、CLI をロードできます (RJ45 コンソール ケーブルは提供されますが、Type-C ケーブルは提供されません)。
次の図に示すように、コンソール ケーブルを使用してデバイスの RJ45 コンソール ポートをコンピューターに接続します。
22 接続
図3-3
コンソール (RJ45) ポートの接続
オマダCampus Stackable L3 Managed Switch
次の図に示すように、Type-C ケーブル (付属していません) を使用して、デバイスの Type-C コンソール ポートをコンピューターに接続します。
図3-4
コンソール (USB) ポートの接続
Note: RJ45 console port and Type-C console port cannot be used concurrently. Type-C Console port takes
priority over the RJ45 console port. The Type-C console port is hot-pluggable while the RJ45 console port is not. Keep the device power
off when plugging the console cable into the RJ45 console port. Do not connect the console port with other ports by RJ45 cable.
3.4インストールの確認
設置が完了したら、次の項目を確認してください。換気のためにデバイスの周囲に5〜10cmのスペースを確保し、空気の流れが確保されていることを確認してください。
十分です。tag電源のeは入力電圧の要件を満たしているtagデバイスの正常動作。電源ソケット、デバイス、ラックは適切に接地されています。デバイスは他のネットワーク デバイスに正しく接続されています。
接続 23
オマダCampus Stackable L3 Managed Switch
3.5電源オン
次の図に示すように、付属の電源コードのメス コネクタをデバイスの電源ソケットに差し込み、プラスのコネクタを電源コンセントに差し込みます。 ボリュームがtag電源のeは入力電圧の要件を満たしているtage (100-240 V ~ 50/60 Hz)。
図3-5
電源への接続
Note: The figure is to illustrate the application and principle. The provided plug and module in your region
may differ from the figures above. Generally PWR1 takes priority over PWR2.
3.6 初期化
デバイスの電源がオンになると、パワーオンセルフテストが開始されます。 一連のテストが自動的に実行され、デバイスが正しく機能することを確認します。 この間、LEDインジケータは次の順序で応答します。
1. PWRLEDインジケータが常に点灯します。 SYSLEDとすべてのポートのLEDインジケータは消灯します。
2. 約 XNUMX 分後、SYS LED とすべてのポートの LED インジケーターが一瞬点滅し、その後消灯します。
3.数秒後、SYS LEDインジケーターが点滅し、初期化が成功したことを示します。
3.7 スタックトポロジ
With stackable design, the switches can be stacked into one stack topology for higher reliability, larger bandwidth, and simpler networking. To build the stack topology, you need to prepare 2-12 switches and enough 10G SFP+/25G SFP28/100G QSFP28 modules/cables. For more details, see the table below:
スイッチ
対応機種
量
S6500-24G4XF S6500-24G4XF, S6500-48G6XF, S6500-24GP4XF, S6500-48GP6XF S6500-48G6XF S6500-24G4XF, S6500-48G6XF, S6500-24GP4XF, S6500-48GP6XF S6500-24GP4XF S6500-24G4XF, S6500-48G6XF, S6500-24GP4XF, S6500-48GP6XF S6500-48GP6XF S6500-24G4XF, S6500-48G6XF, S6500-24GP4XF, S6500-48GP6XF S6500-24M4Y S6500-24M4Y, S6500-24MPP4Y, S6500-48M6Y, S6500-48MPP6Y S6500-24MPP4Y S6500-24M4Y, S6500-24MPP4Y, S6500-48M6Y, S6500-48MPP6Y
2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode)
24 接続
オマダCampus Stackable L3 Managed Switch
S6500-48M6Y S6500-24M4Y, S6500-24MPP4Y, S6500-48M6Y, S6500-48MPP6Y
S6500-48MPP6Y S6500-24M4Y, S6500-24MPP4Y, S6500-48M6Y, S6500-48MPP6Y
S7500-26XF6Y S7500-26XF6Y
S7500-48XF4C S7500-48XF4C
S7500-24Y4C S7500-24Y4C
S7500-48Y8C S7500-48Y8C
S7500-32C
S7500-32C
2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode)
さまざまなシナリオに対応する 3 つのスタック トポロジ構造があります。ニーズに応じて適切なトポロジを構築してください。
1. チェーントポロジー:チェーントポロジーは比較的シンプルで、最初のユニットと最後のユニット間のケーブル接続を必要としません。長距離スタッキングに適していますが、信頼性は比較的低くなります。
図3-6
チェーントポロジー
スタッキングポートグループ2
スタッキングポートグループ1
…
2. リング トポロジ: リング トポロジは、チェーン トポロジに比べて信頼性が高くなります。リング トポロジ内のチェーンの XNUMX つが切断されると、リング トポロジはチェーン トポロジになりますが、スタック システム全体は正常に動作します。リング トポロジでは、最初のユニットと最後のユニットの間にケーブル接続が必要なので、長距離のスタッキングには適していません。
図3-7
リングトポロジー
スタッキングポートグループ2
スタッキングポートグループ1
…
接続 25
オマダCampus Stackable L3 Managed Switch
3. スター トポロジ: スター トポロジでは、スイッチが中央のメイン スイッチに接続されるため、統合管理を提供しながら、メンバー スイッチ間のデータ転送速度を大幅に向上させることができます。
図3-8
スタートポロジ
スタッキングポートグループ2
スタッキングポートグループ3
スタッキングポートグループ1
…
Note: The stacking port is not allowed to connect to non-stacking port, as it may affect the operation of the
device. Stacking ports with the same group ID are not allowed to connect to stacking ports with different
group IDs, neither to different devices. A stacking port group is a logical port dedicated to stacking and needs to be bound to a stacking port.
A stacking port group can be bound to one or more stacking ports to improve bandwidth and reliability.
26 接続
オマダCampus Stackable L3 Managed Switch
第4章 構成
4.1構成オーバーview
スイッチは、次のXNUMXつの構成オプションをサポートしています。
スタンドアロンモード: スイッチを単独で設定および管理します。コントローラモード: ネットワークデバイスを集中的に設定および管理します。
アクセス ポイント、スイッチ、ゲートウェイなどの大量のデバイスで構成される大規模ネットワーク。
注:スイッチをスタンドアロンモードからコントローラーモードに変更すると、スイッチの構成が失われます。 詳しくは、公式ダウンロードセンターの関連資料をご覧ください。 webサイト: https://support.omadanetworks.com/product/。
4.2スタンドアロンモード
スタンドアロン モードでは、コンピュータを使用して、GUI (グラフィカル ユーザー インターフェイス) または CLI (コマンドライン インターフェイス) を使用してスイッチを設定および管理します。
図4-1
スタンドアロンモードのトポロジ
スイッチ
PC
GUIの使用
1.スイッチの管理ページにアクセスするには、スイッチとコンピューターが同じサブネット内にあることを確認してください。 ブラウザを開き、アドレスフィールドにスイッチのIPアドレスを入力して、Enterキーを押します。
スイッチが DHCP サーバー (通常はゲートウェイ) から IP アドレスを取得する場合は、DHCP サーバー上でスイッチの IP アドレスを見つけます。
そうでない場合は、デフォルトのIPアドレス192.168.0.1を使用して、スイッチの管理ページを起動します。
2. 初回ログイン時は、ネットワークとデバイスの保護を強化するために、ユーザー名とパスワードを設定してください。その後は、システムが自動的にログインインターフェースにリダイレクトし、新しく作成された認証情報で認証を行います。
3.ログインに成功すると、メインページが表示されます。 上部と左側のメニューをクリックして、対応する機能を構成できます。
詳細な構成については、ユーザーガイドおよびCLIガイドを参照してください。 ガイドは私たちの公式のダウンロードセンターで見つけることができます webサイト: https://support.omadanetworks.com/product/。
CLI の使用 CLI 経由でスイッチにアクセスするには、Telnet または SSH 接続を設定します。
構成27
オマダCampus Stackable L3 Managed Switch
コンソール ポートを使用してスイッチにアクセスします。 コンソール ポートを使用する場合は、PC 上で端末エミュレーション プログラム (ハイパー ターミナルなど) を起動し、端末エミュレーション プログラムを次のように設定します。
ボーレート 38400 bps
データビット 8
パリティなし
ストップビット 1
フロー制御なし
詳細な構成については、ユーザーガイドおよびCLIガイドを参照してください。 ガイドは私たちの公式のダウンロードセンターで見つけることができます webサイト: https://support.omadanetworks.com/product/。
Note: You may need to change the password the first time you log in, which will better protect your network and devices.
4.3コントローラーモード
Controller Mode applies to the large scale network with mass devices. All devices can be centrally configured and monitored via Omada Pro Hardware Controller (C5300), Omada Pro Software Controller, or Omada Pro Cloud-Based Controller.
Note: Before the following configurations, make sure the switch can access the internet. When using Omada Pro Hardware/Software/Cloud-based Controller, make sure the switch and the controller are in the same subnet. Typically, the switch obtains IP address from the DHCP server. You can check the switch’s IP address on the DHCP server.
Via Omada Pro Hardware Controller (C5300)
Omada Pro Hardware Controller (C5300) is a good alternative if you have no spare PC to keep running Omada Pro Software Controller in the network. It needs to be purchased additionally. Follow the steps below to configure the Omada Pro Hardware Controller (C5300).
図4-2
Manage the network via Omada Pro Hardware Controller (C5300)
ゲートウェイスイッチ
Omada Pro Hardware Controller (C5300) EAP
28 構成
EAP
EAP
クライアント
オマダCampus Stackable L3 Managed Switch
Note: Before you start, be sure to power up and connect your devices according to the topology figure. A DHCP server (typically a gateway with DHCP function enabled) is required to assign IP addresses to
the EAPs and clients in your local network. Omada Pro Controller must have network access to some Omada campus devices (the gateway,
switch, or APs) in order to find, adopt, and manage them.
1. ゲートウェイのIPアドレスを確認します。PCでコマンドラインを開き、「ipconfig」と入力します。結果リストで、ゲートウェイのIPアドレスであるデフォルトゲートウェイを見つけます。
2. 起動する web ブラウザを開き、ゲートウェイのIPアドレスを入力します。ゲートウェイにログインします。 web ページに移動します。次に、[ネットワーク] > [LAN] > [DHCP クライアント リスト] に移動して、MAC アドレスに基づいてコントローラーの IP アドレスを見つけます。
3. アドレスバーにコントローラーのIPアドレスを入力して、 web ページ。
4. On the Omada Pro Controller’s web ページで、ウィザードに従ってクイックセットアップを完了します。
5.クイックセットアップ後、ログインページが表示されます。 作成したユーザー名とパスワードを入力し、[ログイン]をクリックします。その後、コントローラーをさらに構成できます。
6. デバイスをリモートで管理する場合は、次の手順に従ってください。
a. コントローラーでクラウド アクセスが有効になっていることを確認します。デフォルトでは、クラウド アクセスは有効になっています。クラウド LED がゆっくり点滅していることを確認します。
b. 起動する web ブラウザで、アドレスバーにhttps://omada.tplinkcloud.comと入力します。 TP-Link IDとパスワードを入力してログインします。[+コントローラーの追加]をクリックし、[ハードウェアコントローラー]を選択してコントローラーを追加します。 次に、コントローラーをさらに構成できます。
For more details, refer to the Installation Guide of C5300.
Omada Pro ソフトウェア コントローラー経由
Download the Omada Pro Software Controller on a PC with Windows OS or Linux OS. Then run the file and follow the wizard to install the Omada Pro Software Controller. Follow the steps below to configure the Controller.
図4-3
Omada Pro ソフトウェア コントローラー経由でネットワークを管理する
ゲートウェイ
スイッチ
コントローラ
Omada Pro ソフトウェア コントローラー AP
AP
AP
ホストPC上で実行
クライアント
構成29
オマダCampus Stackable L3 Managed Switch
1. Launch the Omada Pro Software Controller on your PC. After the initiation process, the controller automatically opens its web ページが表示されない場合は、「ブラウザを起動してネットワークを管理する」をクリックします。
2. On the Omada Pro Controller’s web ページで、ウィザードに従ってクイックセットアップを完了します。
3.クイックセットアップ後、ログインページが表示されます。 作成したユーザー名とパスワードを入力し、[ログイン]をクリックします。その後、コントローラーをさらに構成できます。
4. デバイスをリモートで管理する場合は、次の手順に従ってください。
a. Make sure that Cloud Access is enabled on your controller and your controller has been bound with your TP-Link ID. On the Omada Pro Controller’s web ページで、[設定] > [クラウド アクセス] に移動してクラウド アクセスを有効にし、TP-Link ID をバインドします。クイック セットアップで設定した場合は、この手順をスキップしてください。
b. 起動する web ブラウザを開き、アドレスバーに https://omada.tplinkcloud.com と入力します。TP-Link ID とパスワードを入力してログインします。TP-Link ID にバインドされているコントローラーのリストが表示されます。次に、[起動] をクリックしてコントローラーをさらに設定できます。
Note: To manage your devices, Omada Pro Software Controller needs to keep running on your computer.
Omada Pro クラウドベース コントローラー経由
Omada Pro クラウドベース コントローラーは、PC にソフトウェア コントローラーをインストールする必要がない優れた代替手段です。
ライセンスは追加で購入する必要があります。
図4-4
Omada Pro クラウドベース コントローラー経由でネットワークを管理
オマダクラウド
ゲートウェイ
スイッチ
AP
AP
AP
AP
クライアント
1. Contact the sales staff to grant the Omada Pro Cloud-Based Controller permission. 2. Launch a web browser and enter https://omada.tplinkcloud.com in the address bar. Log in with
your TP-Link ID.
30 構成
オマダCampus Stackable L3 Managed Switch 3. Click + Add Controller and choose Cloud-Based Controller to add an Omada Pro Controller. Then
you can launch the controller to adopt and manage devices. * Omada App With the Omada app, you can also manage your controller at a local site or a remote site via your mobile device. For the detailed configurations, refer to the User Guide of the controller. The guide can be found on the download center of our official webサイト: https://support.omadanetworks.com/product/。
構成31
オマダCampus Stackable L3 Managed Switch
付録 A トラブルシューティング
Q1。 スイッチのユーザー名とパスワードを忘れた場合はどうすればよいですか?
1. PC のコンソール ポートをスイッチのコンソール ポートに接続し、端末エミュレーション プログラムを開きます。
2. スイッチの電源をオフにして再起動します。端末エミュレーション プログラムで指示された操作を実行して、bootUtil メニューにアクセスします。操作は製品によって異なります。実行可能な操作は次のとおりです。 · 任意のキーを押して自動ブートを停止します。 · CTRL-B を押して bootUtil メニューにアクセスします。
3. bootUtilメニューが表示されます。「6」と入力して「パスワード回復」オプションを選択し、「Y」と入力してすべてのユーザーとパスワードを削除します。その後、ユーザー名とパスワードをリセットできます。
Q2. PWR LEDが異常な動作をするのはなぜですか?電源システムが正常に動作している場合、PWR/Power LEDは点灯します。PWR/Power LEDが異常な動作をする場合は、以下の手順をお試しください。
1. 電源ケーブルが正しく接続され、電源接点が正常であることを確認します。2. ボリュームを確認します。tag電源のeは入力電圧の要件を満たしているtageの
スイッチ。
Q3. アクセスできない場合はどうすればいいですか? web 管理ページですか? 次の操作を試してください。
1. スイッチのすべてのポートLEDをチェックし、イーサネットケーブルが正しく接続されていることを確認します。 2. スイッチの別のポートを試し、イーサネットケーブルが適切で正常に動作することを確認します。 3. スイッチの電源をオフにし、しばらくしてから再度電源をオンにします。 4. PCのIPアドレスがスイッチのサブネット内に設定されていることを確認します。 5. それでも設定ページにアクセスできない場合は、スイッチを工場出荷時のデフォルトにリセットします。
PC の IP アドレスは 192.168.0.x (「x」は 2 から 254 までの任意の数字)、サブネット マスクは 255.255.255.0 に設定する必要があります。
Q4. 端末エミュレーションプログラムが正しく表示されないのはなぜですか?以下の手順を試してください。
1. 電源が正常で、コンソールケーブルが正しく接続されていることを確認します。2. コンソールケーブルが正しいタイプであるかどうかを確認します。3. 端末エミュレーションプログラムのパラメータが正しいことを確認します。ビット/秒を設定します。
38400、データ ビットは 8、パリティはなし、ストップ ビットは 1、フロー制御はなし。
32 付録A トラブルシューティング
オマダCampus Stackable L3 Managed Switch
付録B 仕様
Specifications for S6500 Series Switches
アイテム
コンテンツ
IEEE 802.3, IEEE 802.3i, IEEE 802.3u, IEEE 802.3ab, IEEE 802.3z, IEEE 802.3ae, IEEE 802.3x
標準
IEEE 802.3af/at (For S6500-24GP4XF, S6500-48GP6XF) IEEE 802.3af/at/bt (For S6500-24MPP4Y, S6500-48MPP6Y)
IEEE 802.3bz, IEEE 802.3by, IEEE 802.3cc (For S6500-24M4Y, S6500-24MPP4Y, S6500-48M6Y, S6500-48MPP6Y)
10BASE-T: 2-pair UTP/STP of Cat. 3,4,5 (maximum 100 m) 100BASE-TX: 2-pair UTP/STP of Cat. 5 or above (maximum 100 m) 1000BASE-T: 4-pair UTP/STP of Cat. 5e or above (maximum 100 m) 2.5GBASE-T: 4-pair UTP/STP of Cat. 5e or above (maximum 100 m) Transmission Medium 1000BASE-SX/LX/LX10/BX10: MMF, SMF 10GBASE-SR/LR: MMF, SMF 10G SFP+ Direct Attach Cable (SM5220-1M, SM5220-3M) 25GBASE-SR/LR: MMF, SMF (SM6110-SR, SM6110-LR) 25G SFP28 Direct Attach Cable (SM6220-1M)
S6500-24G4XF/S6500-24M4Y: PWR1, PWR2, SYS, FAN, MGMT, MST, SPEED, STK, Port 1-24, Port 25-28 S6500-24GP4XF/S6500-24MPP4Y: PWR1, PWR2, SYS, FAN, PoE Max, MGMT, MST, SPEED, STK, PoE, Port 1-24, Port 25-28 LED S6500-48G6XF/S6500-48M6Y: PWR1, PWR2, SYS, FAN, MGMT, MST, SPEED, STK, Port 1-48, Port 49-54 S6500-48GP6XF/S6500-48MPP6Y: PWR1, PWR2, SYS, FAN, PoE Max, MGMT, MST, SPEED, STK, PoE, Port 1-48, Port 49-54
付録B 仕様 33
オマダCampus Stackable L3 Managed Switch
PoE予算
For S6500-24GP4XF: 402W (with 1*PSM500-AC, by default) 720W (with 1*PSM900-AC) 720W (with 2*PSM500-AC) 720W (with 1*PSM500-AC and 1*PSM900-AC) 720W (with 2*PSM900-AC) For S6500-48GP6XF: 764W (with 1*PSM900-AC, by default) 384W (with 1*PSM500-AC) 812W (with 2*PSM500-AC) 1176W (with 1*PSM500-AC and 1*PSM900-AC) 1440W (with 2*PSM900-AC) For S6500-24MPP4Y: 751W (with 1*PSM900-AC, by default) 378W (with 1*PSM500-AC) 802W (with 2*PSM500-AC) 1168W (with 1*PSM500-AC and 1*PSM900-AC) 1534W (with 2*PSM900-AC) For S6500-48MPP6Y: 701W (with 1*PSM900-AC, by default) 328W (with 1*PSM500-AC) 752W (with 2*PSM500-AC) 1118W (with 1*PSM500-AC and 1*PSM900-AC) 1484W (with 2*PSM900-AC)
Operating Temperature & Altitude
For S6500-24G4XF/S6500-48G6XF/S6500-24M4Y/S6500-48M6Y: -5 °C to 50 °C (23 °F to 122 °F) @ 300 meters -5 °C to 45 °C (23 °F to 113 °F) @ 2,000 meters -5 °C to 40 °C (23 °F to 104 °F) @ 3,000 meters For S6500-24GP4XF/S6500-48GP6XF/S6500-24MPP4Y/S6500-48MPP6Y: -5 °C to 45 °C (23 °F to 113 °F) @ 2,000 meters -5 °C to 40 °C (23 °F to 104 °F) @ 3,000 meters
保管温度 -40 °C ~ 70 °C (-40 °F ~ 158 °F)
動作湿度 10% ~ 90% RH 結露なきこと
保管湿度
5%〜90%RH結露なし
34 付録B 仕様
オマダCampus Stackable L3 Managed Switch
Specifications for S7500 Series Switches
アイテム
コンテンツ
標準
IEEE 802.3, IEEE 802.3x IEEE 802.3z, IEEE 802.3ae (For S7500-26XF6Y, S7500-48XF4C, S7500-24Y4C, S7500-48Y8C IEEE 802.3by, IEEE 802.3cc (For S7500-26XF6Y, S7500-24Y4C, S7500-48Y8C) IEEE 802.3 ba, IEEE 802.3bm (For S7500-48XF4C , S7500-24Y4C, S7500-48Y8C, S7500-32C)
1000BASE-SX/LX/LX10/BX10: MMF, SMF 10GBASE-SR/LR: MMF, SMF 10G SFP+ Direct Attach Cable (SM5220-1M, SM5220-3M) 25GBASE-SR/LR: MMF, SMF (SM6110-SR, SM6110-LR) 25G SFP28 Direct Attach Cable (SM6220-1M) 40GBASE-SR4/LR4: MMF, SMF (For S7500-48XF4C, S7500-24Y4C, Transmission Medium S7500-48Y8C, S7500-32C) 40G QSFP+ Direct Attach Cable (For S7500-48XF4C, S7500-24Y4C, S7500-48Y8C, S7500-32C) 100GBASE-SR4/LR4: MMF, SMF (SM9110-SR4 for S7500-48XF4C, S7500-24Y4C, S7500-48Y8C, S7500-32C) 100G QSFP28 Direct Attach Cable (SM9220-1M for S7500-48XF4C, S7500-24Y4C, S7500-48Y8C, S7500-32C)
導かれた
Operating Temperature & Altitude
S7500-26XF6Y: PWR1, PWR2, SYS, FAN, MGMT, MST, SPD, STK, SFP+, SFP28 S7500-48XF4C: PWR1, PWR2, SYS, FAN, MGMT, MST, SPEED, STK, SFP+, QSFP28 S7500-24Y4C: PWR1, PWR2, SYS, FAN, MGMT, MST, SPD, STK, SFP28, QSFP28 S7500-48Y8C: PWR1, PWR2, SYS, FAN, MGMT, MST, SPEED, STK, SFP28, QSFP28 S7500-32C: PWR1, PWR2, SYS, MGMT, FAN, MST, SPEED, STK, QSFP28 -5 °C to 45 °C (23 °F to 113 °F) @ 300 meters -5 °C to 40 °C (23 °F to 104 °F) @ 2,000 meters -5 °C to 35 °C (23 °F to 95 °F) @ 3,000 meters
保管温度 -40 °C ~ 70 °C (-40 °F ~ 158 °F)
動作湿度 10% ~ 90% RH 結露なきこと
保管湿度
5%〜90%RH結露なし
For S7500-26XF6Y, S7500-48XF4C, and S7500-24Y4C, the maximum operating temperature supported can reach 50 °C (122 °F) @ 300 meters, 45 °C (113 °F) @ 2,000 meters, and 40 °C (104 °F) @ 3,000 meters.
対応高度は海抜5000メートルから2000メートルまでです。高度が220メートルを超える場合、高度が1メートル上昇するごとに、最大動作温度が1.8°C(XNUMX°F)低下することにご注意ください。
付録B 仕様 35
オマダCampus Stackable L3 Managed Switch
電源モジュールの仕様
PSM500-AC
(For S6500-24GP4XF/ S6500-48GP6XF/ S6500-24MPP4Y/ S6500-48MPP6Y)
PSM900-AC
(For S6500-24GP4XF/ S6500-48GP6XF/ S6500-24MPP4Y/ S6500-48MPP6Y)
PSM550-AC
(For S6500-24M4Y/ S6500-48M6Y/ S7500-26XF6Y/ S7500-48XF4C/ S7500-24Y4C/ S7500-48Y8C/ S7500-32C)
電源入力
100 V240 V~ 50/60 Hz 8A
100-120V (included)~ 50/60Hz 12A (for locations using low voltage, see specifications for specific countries/ regions)
120 (not included)240V~ 50/60Hz 10A (for other locations)
100 V240 V~ 50/60 Hz 7A
出力巻tage
Primary: 53.5 VDC Standby: 12 VDC
Primary: 53.5 VDC Standby: 12 VDC
Primary: 12 VDC Standby: 12 VDC
出力電流
9.35 A(最大)
16.5 A(最大)
45 A(最大)
出力電力
500 W(最大)
900 W(最大)
550 W(最大)
動作高度
For PSM500-AC/PSM900-AC: Sea level to 3000 m For PSM550-AC: Sea level to 5000 m
36 付録B 仕様
CEマークの警告
この製品はクラス A 製品です。家庭環境では、この製品が無線干渉を引き起こす可能性があり、その場合、ユーザーは適切な対策を講じる必要があります。
EU適合宣言
TP-Linkは、本スイッチがEU指令2014/30/EU、2014/35/EU、2011/65/EU、および(EU)2015/863の必須要件およびその他の関連規定に準拠していることをここに宣言します。EU適合宣言の原本は、https://www.tp-link.com/en/support/ce/ でご覧いただけます。
英国適合宣言
TP-Linkは、本スイッチが2016年電磁両立性規制および2016年電気機器(安全)規制の必須要件およびその他の関連規定に準拠していることをここに宣言します。英国の適合宣言の原本は、https://www.tp-link.com/support/ukca/でご覧いただけます。
、。
注意:
二極、中性ヒューズ。保守作業の前に主電源を外してください。
安全情報
· 本装置は水、火、湿気、高温の環境から遠ざけてください。 · 本装置の分解、修理、改造はしないでください。修理が必要な場合は、当社までご連絡ください。 · 本装置は底面を下にして置いてください。 · 電源コードのプラグは切断装置として使用し、コンセントは
簡単にアクセスできます。 · 製品を電源コードを通してアース接続された壁のコンセントに差し込んでください。
or plug. · The socket-outlet shall be installed near the equipment and shall be easily accessible. · The PoE ports shall not be used to charge lithium batteries or devices supplied by lithium
電池。
· Operating temperature: For S6500-24G4XF/S6500-48G6XF/S6500-24M4Y/S6500-48M6Y/S7500-26XF6Y/ S7500-48XF4C/S7500-24Y4C: -5 °C to 50 °C (23 °F to 122 °F) @ 300 meters -5 °C to 45 °C (23 °F to 113 °F) @ 2,000 meters -5 °C to 40 °C (23 °F to 104 °F) @ 3,000 meters For S6500-24GP4XF/S6500-48GP6XF/S6500-24MPP4Y/S6500-48MPP6Y: -5 °C to 45 °C (23 °F to 113 °F) @ 2,000 meters -5 °C to 40 °C (23 °F to 104 °F) @ 3,000 meters S7500-48Y8C/S7500-32C: -5 °C to 45 °C (23 °F to 113 °F) @ 300 meters -5 °C to 40 °C (23 °F to 104 °F) @ 2,000 meters -5 °C to 35 °C (23 °F to 95 °F) @ 3,000 meters
· : S6500-24G4XF/S6500-48G6XF/S6500-24M4Y/S6500-48M6Y/S7500-26XF6Y/S7500-48XF4C/ S7500-24Y4C -5°C 50°C23°F 122°F@ 300 -5°C 45°C23°F 113°F@ 2,000 -5°C 40°C23°F 104°F@ 3,000 S6500-24GP4XF/S6500-48GP6XF/S6500-24MPP4Y/S6500-48MPP6Y -5°C 45°C23°F 113°F@ 2,000 -5°C 40°C23°F 104°F@ 3,000 S7500-48Y8C/S7500-32C -5°C 45°C23°F 113°F@ 300 -5°C 40°C23°F 104°F@ 2,000 -5°C 35°C23°F 95°F@ 3,000
This equipment is not suitable for use in locations
where children are likely to be present.
デバイスを操作する際は、上記の安全情報を読んで従ってください。デバイスの不適切な使用により事故や損傷が発生しないことを保証するものではありません。この製品を慎重に使用し、自己責任で操作してください。
技術サポート、ユーザー ガイド、その他の情報については、https://support.omadanetworks.com/ にアクセスするか、QR コードをスキャンしてください。