LTECH-ロゴ

LTECH KBS1 Switch Module

LTECH-KBS1-Switch-Module-product

製品情報

The Switch Module Model KBS1 is a versatile device that supports Bluetooth 5.2 SIG Mesh communication protocol, offering strong networking capabilities, reliability, and stability. It enables app control even when manually turned off, catering to diverse needs.

システム図

LTECH-KBS1-Switch-Module-fig (1)

製品紹介

  • Bluetooth 5.2 SIG Mesh communication protocol, offering strong networking capabilities, reliability, and stability.
  • Supports both mechanical and reset switches, enabling app control even when manually turned off to meet diverse needs; supports power-on or power-off scenarios for hotel-style applications.
  • Supports power-on or power-off scenarios to accommodate hotel-style usage scenarios;
  • Supports OTA (Over-the-Air) online upgrades, ensuring timely feature updates and usage safety, keeping the product up-to-date.
  • Supports direct connection of mobile phones to devices, enabling direct control of devices through the L-Home app;
  • Supports gateway-free control, enabling LAN remote control, wireless panels, group control, and more.
  • Supports integration with a smart gateway to enable remote control of home devices, making life more convenient.
  • Compact size, allowing easy installation in European, American, and national standard junction boxes, suitable for various installation scenarios.
  • Supports power-off reset functionality and mechanical key reset functionality.

技術仕様

モデル KB1 動画
ワイヤレスタイプ Bluetooth 5.2SIGメッシュ
チャンネルを切り替える 1CH
営業巻tage 100-240V~, 50/60Hz,
Max. load parameters of the relay Resistive load: 1000W@230Vac, 500W@110Vac Capacitive load: 400W@230Vac, 200W@110Vac
リレーサージ電流 70A@10ms
動作温度 -25°C〜50°C
製品サイズ 長さ45×幅45.5×高さ20.5(mm)
製品重量 30グラム
標準 UL 8750、EN 61347-2-13:2014+A1:2017、EN 61347-1:2015+A1:2021、 EN 62493:2015/A1:2022

製品画像

LTECH-KBS1-Switch-Module-fig (2)

製品サイズ
単位:mmLTECH-KBS1-Switch-Module-fig (3)

配線図

  1. Mechanical Switch Wiring DiagramLTECH-KBS1-Switch-Module-fig (4)
  2. Push Switch Wiring DiagramLTECH-KBS1-Switch-Module-fig (5)

推奨アプリケーション

  1. ワイヤレス照明制御LTECH-KBS1-Switch-Module-fig (6)
  2. After setting up the remote control association with the switch module via the APP, both the APP and the remote control can be used to control the device.LTECH-KBS1-Switch-Module-fig (7)
  3. Supports local scenes, gateway-free operation, and controllable even when offline.LTECH-KBS1-Switch-Module-fig (8)
  4. Work with intelligent gateway, it can realize visual control, cloud scene and automatic linkage.LTECH-KBS1-Switch-Module-fig (9)

アプリの操作手順

  1. アカウントを登録する
    携帯電話で下の QR コードをスキャンし、指示に従ってアプリのインストールを完了してください。LTECH-KBS1-Switch-Module-fig (10)
  2. ペアリング操作
    After creating a new home in the APP, click the “+” in the upper right corner on the【Room】interface to add devices. Select “Smart Module” from the device list and follow the on-screen instructions to complete the addition.LTECH-KBS1-Switch-Module-fig (11)
  3. Power On/Off Scene Settings
    On the settings page, you can configure the scenes to be executed when the device powers on or off, along with the execution times for these scenes.LTECH-KBS1-Switch-Module-fig (12)
  4. Binding Interface Settings
    After pairing is complete, enter the Smart Remote/Smart Wireless Switch binding interface. Select the switch module device to associate it. You can then control the device’s power state via the Smart Remote/Smart Wireless Switch. You may also unbind the device from this interface.LTECH-KBS1-Switch-Module-fig (13)
  5. グループコントロール
    Supports grouping identical switch modules or single switches from dual-channel relays (KBS) into clusters. Users can conveniently control power on/off operations for the entire group. To add a device, navigate to the device list, select “Group – Switch Module Group,” modify the group name as prompted, click “Next,” check the devices to include in the group, then save.LTECH-KBS1-Switch-Module-fig (14)
  6. 地元の風景
    Switch to the 【Smart】 page, click “+” in the upper right corner to create a local scene, and after setting the execution action, you can realize the local linkage of Bluetooth devices.LTECH-KBS1-Switch-Module-fig (15)
  7. クラウドシーンと自動化
    Make sure that a smart gateway, such as SP-GW-6S,has been added to the family. Cloud scenes: Switch to the 【Smart】 interface and click “+” to create a cloud scene. After setting the execution action, remote linkage can be achieved. Automation: Select “Automation” in the【Smart】page and click “+” to create automation. You can choose local/cloud execution mode,and set trigger conditions and execution actions. When the set trigger conditions are met, a series of device actions are automatically triggered to achieve remote linkageLTECH-KBS1-Switch-Module-fig (16)
  8. 工場出荷時のデフォルトにリセット
    Mechanical Reset: Connect device to lighting fixture. Hold reset button for 15s until indicator light flashes red rapidly, then release. Press reset button 3 times briefly within 3s. Slow red flash means factory settings restored; rapid blue flash means setup is complete. Power Cycle Reset: With the power disconnected, use the switch to power on the device for 15 seconds, then power off for 2 seconds. Repeat this power cycle six times (each cycle: 2 seconds on, 5 seconds off). After the seventh power-on cycle, the load lamp will flash three times, indicating a successful reset to factory settings. APP Reset: Click the “LTECH-KBS1-Switch-Module-fig 18 ” on the switch module to enter the main interface, then click the ” ” in the upper right corner to access the settings interface. Click “Delete Device” to complete the reset.LTECH-KBS1-Switch-Module-fig (17)

注意

  • 製品の設置と試運転は、資格のある専門家が行う必要があります。
  • Our company products are and not lightningproof non-waterproof(special models excepted). Please avoid the sun and rain. When installed outdoors, please ensure they are mounted in a water proof enclosure or in an area equipped with lightning protection devices
  • 放熱性が良好であれば、製品の寿命が延びます。換気を良くしてください。
  • ワーキングボリュームかどうかを確認してくださいtag使用されるeは、製品のパラメータ要件に準拠しています。
  • 使用するワイヤーの直径は、接続する照明器具に負荷をかけ、しっかりと配線できる必要があります。
  • 製品の電源を入れる前に、照明器具に損傷を与える原因となる誤った接続の場合に備えて、すべての配線が正しいことを確認してください。
  • 万が一、故障した場合は、ご自身で修理しないでください。 ご不明な点がございましたら、サプライヤーにお問い合わせください。

保証契約

  • 納品日からの保証期間:5年。
  • 品質問題の無料修理または交換サービスは、保証期間内に提供されます。

以下の保証の除外:
Following conditions are not wit in the guarantee range of free repairing or replacement servi

  • 保証期間を超えています。
  • 高容量による人工的な損傷tage、過負荷、または不適切な操作。
  • Products with severe physical damage. Damage caused by natural disasters and force majeure.
  • Warranty labels and barcodes have been damaged. No any contract signed by our company.
  1. 修理または交換はお客様への唯一の救済手段となります。当社は、法律で認められる場合を除き、付随的損害または結果的損害については一切責任を負いません。
  2. 当社は本保証の条件を修正または調整する権利を有し、書面による免責が優先されます。
    ※本書は予告なく変更する場合があります。 商品の機能は商品によって異なります。 ご不明な点がございましたら、弊社公式販売店までお気軽にお問い合わせください。

よくある質問

Q: Can the Switch Module be used with both mechanical and reset switches?

A: Yes, the Switch Module supports both mechanical and reset switches for versatile control options.

Q: 営業ボリュームはいくらですか?tage range of the Switch Module?

A: 営業ボリュームtage range is 100-240V~, 50/60Hz, making it suitable for different power systems.

What should I do if the device cannot be found during the search?

Please check the following options: Ensure the device is powered on and functioning properly. Ensure the phone and the device are as close as possible, preferably within 15 meters. Ensure the device has not been added before. If it has, please manually restore it to factory settings.