1. はじめに
The OFITE Model 900 Viscometer is a highly precise instrument designed for measuring the viscosity of fluid samples. It utilizes a Couette coaxial cylinder system with a transducer to accurately measure the induced rotation of the bob immersed in the fluid. This viscometer offers exceptional control and data acquisition capabilities, making it suitable for research applications. It can be seamlessly integrated with a computer via a serial (RS-232) port and operated using OFITE's proprietary Windows-based ORCADA software, providing a fully automated and user-friendly experience. The compact and portable design, coupled with its robust construction, ensures reliable performance in various environments. Whether you need to analyze viscosity for quality control, product development, or scientific research, the OFITE Model 900 Viscometer delivers accurate and consistent results.
2. セットアップ
Follow these steps to set up your OFITE Model 900 Viscometer for operation.
2.1 開梱と検査
Carefully unpack all components from the carrying case. Verify that all included components are present and undamaged. The standard package includes the Viscometer Unit, Carrying Case, Power Cables, and Calibration Accessories.

図1: The OFITE Model 900 Viscometer unit and its accessories, including power cables and a sample container, are securely stored within a protective foam-lined carrying case, ready for transport or setup.
2.2 コンポーネントの組み立て
- Place the viscometer unit on a stable, level surface.
- Connect the power cable to the viscometer and a suitable power outlet.
- If using computer control, connect the serial (RS-232) cable from the viscometer to your computer.
- Ensure the bob and rotor cup are clean and properly seated. Refer to the images below for correct placement of the bob and cup assembly.

図2: クローズアップサイド view of the OFITE Model 900 Viscometer, highlighting the lower section where the rotor cup and bob are positioned. This view shows the connection points and the general structure of the measurement area.

図3: This image provides an alternative side perspective of the OFITE Model 900 Viscometer, emphasizing the precise alignment of the bob within the rotor cup. A control knob labeled 'LOW' and 'HIGH' is visible, likely for speed or torque adjustment.
3. 操作手順
This section details the steps for performing viscosity measurements using the Model 900 Viscometer.
3.1 電源投入と初期チェック
- Ensure the viscometer is properly connected to power.
- 通常、ユニットの背面または側面にある主電源スイッチをオンにします。
- The display on the front panel should illuminate.

図4: The front control panel of the OFITE Model 900 Viscometer, featuring a digital display at the top and a numerical keypad below it. Various function buttons like 'CAL', 'NEXT', 'SET UP', 'MUD', and 'CEM' are also visible, indicating control and calibration options.
3.2年ample Preparation and Loading
- Prepare your fluid sample according to your testing protocol.
- 慎重に注ぎますample into the rotor cup, ensuring the bob is fully immersed and the fluid level is appropriate for measurement. Avoid air bubbles.
3.3 測定の実行
- Using the control panel or the ORCADA software, select the desired test parameters (e.g., shear rate, temperature).
- Initiate the measurement cycle. The viscometer will begin rotating the rotor cup, and the transducer will measure the induced angle of rotation of the bob.
- Monitor the display for real-time readings or observe the data acquisition through the ORCADA software.
- Once the measurement is complete, record the data.
3.4 Data Acquisition and Analysis (with ORCADA Software)
For automated control and comprehensive data analysis, connect the viscometer to a computer running OFITE's ORCADA software. The software allows for:
- Real-time data plotting.
- Customizable test profiles.
- データの保存とエクスポート。
- Advanced rheological calculations.
4. メンテナンス
Proper maintenance ensures the longevity and accuracy of your Model 900 Viscometer.
4.1 クリーニング
- After each use, thoroughly clean the rotor cup and bob with an appropriate solvent for the tested fluid.
- Wipe down the exterior of the viscometer with a soft, damp 布で拭いてください。仕上げを傷める可能性のある研磨剤入りの洗剤や溶剤の使用は避けてください。
- Ensure no fluid enters the internal components of the viscometer.
4.2 キャリブレーション
Regular calibration is crucial for maintaining measurement accuracy. Use the provided calibration accessories and follow the calibration procedure outlined in the ORCADA software or a separate calibration guide (if provided by OFITE). It is recommended to calibrate the instrument at regular intervals or if you suspect measurement inaccuracies.
4.3 ストレージ
When not in use, store the viscometer in its carrying case in a clean, dry environment, away from extreme temperatures and direct sunlight.
5。 トラブルシューティング
This section provides solutions to common issues you might encounter with the Model 900 Viscometer.
| 問題 | 考えられる原因 | 解決 |
|---|---|---|
| Viscometer does not power on | No power supply; faulty power cable; unit switch off | Check power cable connection; ensure power outlet is functional; turn on main power switch. |
| 不正確な測定値 | Improper calibration; dirty bob/cup; incorrect sample preparation; damaged bob/cup | Perform calibration; clean bob and cup thoroughly; ensure proper sample loading; inspect bob/cup for damage and replace if necessary. |
| Software (ORCADA) not connecting | RS-232 cable disconnected; incorrect COM port selected; software driver issue | Verify RS-232 cable connection; check COM port settings in ORCADA; reinstall software drivers if needed. |
| モーターが回転しない | Obstruction in rotor cup; motor fault | Check for and remove any obstructions; if problem persists, contact OFITE support. |
6. 仕様
Key technical specifications for the OFITE Model 900 Viscometer:
- モデル: モデル900
- タイプ: Couette Coaxial Cylinder Rotational Viscometer
- 測定原理: Transducer measures induced angle of rotation of bob
- 接続性: Serial (RS-232) port for computer integration
- ソフトウェアの互換性: OFITE's Windows-based ORCADA software
- 含まれるコンポーネント: Viscometer Unit, Carrying Case, Power Cables, Calibration Accessories
- 工事: 頑丈で耐久性のあるデザイン
- メーカー: Ofite
- 最初に入手可能: 9年2024月XNUMX日
7. 保証とサポート
For information regarding product warranty, technical support, or service, please refer to the documentation provided with your purchase or visit the official OFITE website. Contacting OFITE directly will ensure you receive accurate and timely assistance for your Model 900 Viscometer.