OFITE Model 900

OFITE Model 900 Viscometer Instruction Manual

Model 900 Rotational Viscometer with Couette Coaxial Cylinder

ブランド: OFITE

1. はじめに

The OFITE Model 900 Viscometer is a highly precise instrument designed for measuring the viscosity of fluid samples. It utilizes a Couette coaxial cylinder system with a transducer to accurately measure the induced rotation of the bob immersed in the fluid. This viscometer offers exceptional control and data acquisition capabilities, making it suitable for research applications. It can be seamlessly integrated with a computer via a serial (RS-232) port and operated using OFITE's proprietary Windows-based ORCADA software, providing a fully automated and user-friendly experience. The compact and portable design, coupled with its robust construction, ensures reliable performance in various environments. Whether you need to analyze viscosity for quality control, product development, or scientific research, the OFITE Model 900 Viscometer delivers accurate and consistent results.

2. セットアップ

Follow these steps to set up your OFITE Model 900 Viscometer for operation.

2.1 開梱と検査

Carefully unpack all components from the carrying case. Verify that all included components are present and undamaged. The standard package includes the Viscometer Unit, Carrying Case, Power Cables, and Calibration Accessories.

OFITE Model 900 Viscometer and accessories neatly packed in a foam-lined carrying case.

図1: The OFITE Model 900 Viscometer unit and its accessories, including power cables and a sample container, are securely stored within a protective foam-lined carrying case, ready for transport or setup.

2.2 コンポーネントの組み立て

  1. Place the viscometer unit on a stable, level surface.
  2. Connect the power cable to the viscometer and a suitable power outlet.
  3. If using computer control, connect the serial (RS-232) cable from the viscometer to your computer.
  4. Ensure the bob and rotor cup are clean and properly seated. Refer to the images below for correct placement of the bob and cup assembly.
側 view of the OFITE Model 900 Viscometer showing the lower section with the rotor cup and bob assembly.

図2: クローズアップサイド view of the OFITE Model 900 Viscometer, highlighting the lower section where the rotor cup and bob are positioned. This view shows the connection points and the general structure of the measurement area.

もう一つの側面 view of the OFITE Model 900 Viscometer, focusing on the bob and cup area with a control knob visible.

図3: This image provides an alternative side perspective of the OFITE Model 900 Viscometer, emphasizing the precise alignment of the bob within the rotor cup. A control knob labeled 'LOW' and 'HIGH' is visible, likely for speed or torque adjustment.

3. 操作手順

This section details the steps for performing viscosity measurements using the Model 900 Viscometer.

3.1 電源投入と初期チェック

  1. Ensure the viscometer is properly connected to power.
  2. 通常、ユニットの背面または側面にある主電源スイッチをオンにします。
  3. The display on the front panel should illuminate.
フロント view of the OFITE Model 900 Viscometer control panel with a digital display and numerical keypad.

図4: The front control panel of the OFITE Model 900 Viscometer, featuring a digital display at the top and a numerical keypad below it. Various function buttons like 'CAL', 'NEXT', 'SET UP', 'MUD', and 'CEM' are also visible, indicating control and calibration options.

3.2年ample Preparation and Loading

  1. Prepare your fluid sample according to your testing protocol.
  2. 慎重に注ぎますample into the rotor cup, ensuring the bob is fully immersed and the fluid level is appropriate for measurement. Avoid air bubbles.

3.3 測定の実行

  1. Using the control panel or the ORCADA software, select the desired test parameters (e.g., shear rate, temperature).
  2. Initiate the measurement cycle. The viscometer will begin rotating the rotor cup, and the transducer will measure the induced angle of rotation of the bob.
  3. Monitor the display for real-time readings or observe the data acquisition through the ORCADA software.
  4. Once the measurement is complete, record the data.

3.4 Data Acquisition and Analysis (with ORCADA Software)

For automated control and comprehensive data analysis, connect the viscometer to a computer running OFITE's ORCADA software. The software allows for:

4. メンテナンス

Proper maintenance ensures the longevity and accuracy of your Model 900 Viscometer.

4.1 クリーニング

4.2 キャリブレーション

Regular calibration is crucial for maintaining measurement accuracy. Use the provided calibration accessories and follow the calibration procedure outlined in the ORCADA software or a separate calibration guide (if provided by OFITE). It is recommended to calibrate the instrument at regular intervals or if you suspect measurement inaccuracies.

4.3 ストレージ

When not in use, store the viscometer in its carrying case in a clean, dry environment, away from extreme temperatures and direct sunlight.

5。 トラブルシューティング

This section provides solutions to common issues you might encounter with the Model 900 Viscometer.

問題考えられる原因解決
Viscometer does not power onNo power supply; faulty power cable; unit switch offCheck power cable connection; ensure power outlet is functional; turn on main power switch.
不正確な測定値Improper calibration; dirty bob/cup; incorrect sample preparation; damaged bob/cupPerform calibration; clean bob and cup thoroughly; ensure proper sample loading; inspect bob/cup for damage and replace if necessary.
Software (ORCADA) not connectingRS-232 cable disconnected; incorrect COM port selected; software driver issueVerify RS-232 cable connection; check COM port settings in ORCADA; reinstall software drivers if needed.
モーターが回転しないObstruction in rotor cup; motor faultCheck for and remove any obstructions; if problem persists, contact OFITE support.

6. 仕様

Key technical specifications for the OFITE Model 900 Viscometer:

7. 保証とサポート

For information regarding product warranty, technical support, or service, please refer to the documentation provided with your purchase or visit the official OFITE website. Contacting OFITE directly will ensure you receive accurate and timely assistance for your Model 900 Viscometer.

関連文書 - モデル900

前view OFITE モデル 900 粘度計: 流体粘度測定の取扱説明書
OFITE モデル 900 粘度計の包括的な取扱説明書。実験室や現場でのアプリケーションで正確な流体粘度を測定するための操作、セットアップ、校正、ソフトウェア統合について詳しく説明しています。
前view OFITE サーモカップ 取扱説明書 - モデル #130-38 シリーズ
OFITEサーモカップモデルの詳細な取扱説明書。概要、操作手順、メンテナンスガイドライン、安全上の注意事項が記載されています。対象モデルは#130-38-20、#130-38-25、#130-38-30、#130-38-35です。
前view OFITE貯留層浸透性試験装置(部品番号127-00)取扱説明書
OFITE 貯留層浸透性試験装置 (部品番号 127-00) の包括的な取扱説明書。仕様、コンポーネント、安全上の注意事項、準備、操作、ソフトウェアの使用、メンテナンスについて詳しく説明しています。
前view OFITE HTHP硬化チャンバー取扱説明書
OFITE HTHP 硬化チャンバーの包括的な取扱説明書。モデル #120-20、#120-25、#120-30 のセットアップ、操作、メンテナンス、トラブルシューティングについて詳しく説明しています。
前view OFITE安全Clamp HTHP流体損失セル用 - 取扱説明書 部品番号170-92
OFITE Safety Clの取扱説明書amp (部品番号170-92) HTHP液漏れセル用に設計されています。OFI Testing Equipment, Inc.による操作、保証、返品ポリシーの詳細が記載されています。
前view OFITE 硫化水素検出キット - 取扱説明書
OFITE硫化水素検出キット(部品番号:145-60)の取扱説明書。硫化水素、キットの構成品、安全上の注意事項、検査手順、保証情報について説明します。