DALY LFP24S

DALY LiFePo4 72V 40A 24S Smart BMS Instruction Manual

1. はじめに

This instruction manual provides essential information for the safe and effective use of your DALY LiFePo4 72V 40A 24S Smart Battery Management System (BMS). This BMS is designed to protect and optimize the performance of 24-series LiFePo4 battery packs, commonly used in energy storage, electric vehicles, electric tools, and solar systems. Please read this manual thoroughly before installation and operation.

2. 安全情報

ハイボリュームでの作業tage battery systems requires extreme caution. Failure to follow safety instructions can result in serious injury, property damage, or death. Always adhere to the following safety guidelines:

3. パッケージ内容

パッケージにすべてのアイテムが揃っていることを確認します。

Contents of the DALY Smart BMS package, including the BMS unit, cables, and manual.

図3.1:例ample of package contents for the DALY Smart BMS.

4.製品オーバーview

The DALY Smart BMS provides comprehensive protection for your LiFePo4 battery pack, including overcurrent, overcharge, overdischarge, short circuit, and temperature protection. It features a robust design with injection patent technology and a patent shell for waterproof, dustproof, shockproof, and anti-static properties.

トップ view of the DALY LiFePo4 24S 72V 40A Smart BMS, showing the main terminals P- and B-, and communication ports.

図4.1:上 view of the DALY Smart BMS, highlighting main connections and communication interfaces.

側 view of the DALY LiFePo4 24S 72V 40A Smart BMS with dimensions: 128mm (5.0 inches) length, 66mm (2.59 inches) width, and 18mm (0.7 inches) thickness. Continuous discharge current is 40A.

Figure 4.2: Dimensions and continuous discharge current rating of the DALY Smart BMS.

5. セットアップとインストール

Careful installation is crucial for the proper functioning of the BMS. Follow these steps precisely:

  1. バッテリーパックを準備します。 Ensure your LiFePo4 battery pack consists of 24 cells in series, with each cell rated at 3.2V.
  2. バランスワイヤを接続します。
    • Before connecting the balance wires to the BMS, ensure all balance wires are correctly welded to their respective battery cell terminals.
    • Connect the balance wire harness to the BMS balance port. Ensure the B- wire (total negative pole) is connected first, followed by B1, B2, and so on, up to B24 (total positive pole).
    • ボリュームを確認するtag各セルの e と総体積tage using a multimeter before proceeding.
  3. Connect Main Power Wires:
    • Connect the main negative wire from the battery pack to the B- terminal on the BMS.
    • Connect the main negative wire for the load/charger to the P- terminal on the BMS.
  4. Connect NTC Temperature Sensor: Plug the NTC sensor into the designated port on the BMS. Position the sensor appropriately on the battery pack to monitor temperature.
  5. Connect Communication Modules (Optional):
    • For Bluetooth connectivity, plug the Bluetooth module into the UART port.
    • For PC communication, connect the UART cable to the UART port and then to a USB-UART converter (if needed) to your computer.
  6. Activate the BMS: After all connections are secure, activate the BMS by pressing the activation button on the power board or by connecting the charger to the battery pack.
Detailed wiring diagram for the DALY Smart BMS, showing connections for battery cells, main power, charger, motor/load, and communication modules.

Figure 5.1: Wiring diagram for the DALY Smart BMS. Ensure all connections are made correctly.

For visual guidance on wiring and connections, refer to the official DALY website tutorial videos: DALY BMS Tutorial Videos.

6. 操作手順

The DALY Smart BMS allows monitoring and parameter modification via Bluetooth app or PC software.

6.1. Bluetoothアプリの操作

Connect the Bluetooth module to the BMS UART port. Download the DALY BMS app from your smartphone's app store. Open the app, search for your BMS, and connect. The initial password for the app is 123456アプリを通じて、次のことができます。

DALY Smart BMS connected via Bluetooth to a smartphone app, displaying battery status and parameters.

Figure 6.1: Monitoring the BMS via the Bluetooth smartphone application.

6.2. PC ソフトウェアの操作

Connect the BMS to your computer using the UART cable and a USB-UART converter. Install the DALY BMS PC software. The PC software offers more detailed control and data logging capabilities, allowing for advanced parameter configuration and firmware updates.

DALY Smart BMS connected to a computer via UART, showing the PC software interface for monitoring and configuration.

Figure 6.2: Interacting with the BMS using PC software via UART connection.

重要: The factory default parameters are general. It is essential to review and adjust these parameters to match the specific capacity (Ah) of your battery pack. Incorrect parameter settings can lead to inaccurate state-of-charge readings and potentially damage the battery. The percentage of remaining power will be inaccurate if the capacity is not set correctly.

7. メンテナンス

To ensure the longevity and optimal performance of your DALY Smart BMS:

8。 トラブルシューティング

If you encounter issues with your DALY Smart BMS, consider the following common troubleshooting steps:

問題考えられる原因解決
BMS not activating/no power outputIncorrect wiring; BMS not activated; low battery voltage.Verify all wiring connections (B-, P-, balance wires). Press the activation button or connect the charger to activate. Check battery voltage; if too low, charge the battery.
Bluetooth接続の問題Bluetooth module not properly connected; app issues; interference.Ensure the Bluetooth module is securely plugged into the UART port. Restart the app and try reconnecting. Check for other Bluetooth devices causing interference. Ensure the app is updated.
Inaccurate State of Charge (SOC)Battery capacity parameter not set correctly in the app/software.Access the app or PC software and set the battery pack's actual Ah capacity.
Overcharge/Overdischarge protection tripping prematurelyProtection parameters set too low/high; faulty cell.Review and adjust overcharge/overdischarge voltage parameters in the app/software to match your battery specifications. Check individual cell voltages for imbalances.

If the problem persists after attempting these steps, please contact DALY customer support for further assistance.

9. 仕様

特徴仕様
モデル番号LFP24S
バッテリーセルの構成LiFePo4 (Lithium Iron Phosphate)
シリーズ構成24S(24個のセルを直列に接続)
名目Voltage72V (for 3.2V rated cells)
連続放電電流40A
通信インターフェースUART (Bluetooth module included)
製品寸法(長さ x 幅 x 高さ)5.03 x 2.6 x 0.51 インチ (128 x 66 x 18 mm)
アイテム重量13.4オンス
メーカーDongguan Daly Electronics Co., Ltd

10. 保証とサポート

DALY Electronics is committed to providing high-quality products and customer satisfaction. This product comes with lifetime technical support.

関連文書 - LFP24S

前view DALY Y Series BMS Technical Specifications and Wiring Guide
Detailed technical specifications, wiring diagrams, and interface descriptions for DALY Y Series Battery Management Systems (BMS), including models YH, YK, and YM. Covers cell counts from 4S to 24S and current ratings up to 200A, with information on the Smart BMS mobile application.
前view DALY DL-R32U-F012S200ATJ-MM00-S4RV LiFePO4 BMS Technical Specifications
Detailed technical specifications, wiring diagrams, and warranty information for the DALY DL-R32U-F012S200ATJ-MM00-S4RV LiFePO4 12S 36V 200A Battery Management System (BMS) with Balance, UART, and Bluetooth.
前view Daly Smart BMS 8-16S 100-200A Product Specification Approval and Manual
Detailed product specification and user manual for the Daly Smart BMS 8-16S 100-200A, covering technical parameters, protection features, LED indicators, communication protocols, and installation instructions.
前view DALY LiFePO4 8S24V200A BMS(4GおよびGNSS搭載) - データシート
DALY LiFePO4 8S24V200Aバッテリー管理システム(BMS)の技術データシート。4G接続、GNSS、UART、NTC温度センサーを搭載。仕様、ピン配置、LEDステータス情報が含まれています。
前view DALY Battery Management System (BMS) User Manual
Comprehensive user manual for the DALY Battery Management System (BMS) with Bluetooth module. Includes information on package contents, safety instructions, connection diagram, activation, and declaration of conformity.