Leviton DOS02-LW

Leviton DOS02-LW Motion Sensor Light Switch Instruction Manual

Model: DOS02-LW

導入

The Leviton DOS02-LW Motion Sensor Light Switch is designed to automatically turn lights on and off based on motion and occupancy. This single-pole device offers convenient hands-free lighting control and can be installed with or without a neutral wire, requiring a ground connection. It is suitable for various applications such as pantries, closets, laundry rooms, and basements, helping to conserve energy by ensuring lights are not left on unintentionally.

特徴

  • 自動操作: Turns lights on/off based on motion, providing a 180° field-of-view カバー範囲は900平方フィートです。
  • 簡単なインストール: スリムプロfile fits most wallboxes.
  • フレキシブル配線: Can be installed with or without a neutral wire; a ground connection is required.
  • 多彩なモード: Can be set for occupancy (auto-on/auto-off) or vacancy (manual-on/auto-off) switching.
  • 負荷互換性: Supports 150W LED/CFL, 250W Incandescent/Halogen, 200VA Magnetic Low Voltage, 250VA Electronic Low Voltage, 2A Resistive loads.
  • カスタマイズ可能な外観: Easily change the color using DOSKT faceplates (sold separately).
  • 日光採集: Lights will not turn on if ample daylight is present in the space.

箱の中身

  • One Leviton Motion Sensor Switch DOS02-LW, White

安全情報

WARNING: TO AVOID FIRE, SHOCK, OR DEATH, ALWAYS TURN OFF POWER AT THE CIRCUIT BREAKER OR FUSE AND TEST THAT POWER IS OFF BEFORE WIRING.

If you are unsure about any part of the instructions or are not comfortable or familiar with electrical wiring, contact a licensed electrician. This device is designed for use with Copper or Copper-Clad wire only. Do not mount near a heat source, in drafty areas, or in motion-heavy areas where unintended motion may trigger the sensor.

インストールに必要なツール

  • マイナスドライバー
  • プラスドライバー
  • 電気工事用ペンチ
  • ワイヤーストリッパー
  • 電気テープ
  • ハンドヘルド巻tageテスター
  • Properly Sized Wire Connectors

インストール

Installation typically takes approximately 15 minutes. Always ensure power is off at the circuit breaker before beginning. The device replaces an existing single-pole switch.

1. インストールの準備

  1. Turn off power at the circuit breaker or fuse for the switch you are replacing.
  2. Remove the existing switch plate and unscrew the old device from the wall box.
  3. Carefully pull the device out until you can clearly see the wires.
  4. ボリュームを使用するtage tester to confirm no power is present in the box.
  5. Disconnect all wiring from the old device and remove it.
  6. Straighten and separate each wire in the wall box. Ensure no exposed metal ends are touching.

2. Identify Wiring Configuration

The Leviton DOS02-LW can be wired with or without a neutral wire. Identify if a neutral wire (typically white) is present in your wall box. The neutral wire may be capped off with a wire connector.

Wiring diagram showing connections for Leviton motion sensor switch

Image: Wiring diagram for the Leviton motion sensor switch, illustrating the various wire connections.

3. デバイスの配線

The device features pre-stripped lead wires. Gently pull on the insulation to remove the pre-stripped section. Twist the exposed stranded copper wire in a clockwise direction to prepare it for termination.

Video: Official Leviton installation guide for Decora Occupancy and Vacancy Sensors, including models DOS02, DVS02, DOS05, and DVS05. This video provides detailed visual instructions for wiring and setup.

Wiring without a Neutral Wire:

  • Connect the green and yellow ground lead wire from the device, along with the green sleeve ground wire, to the ground wire in the wall box using a properly sized wire connector.
  • Connect the black lead wires from the device to the black line and load wires in the wall box. The line and load wires can be wired interchangeably.
  • For DOS05 or DVS05 models (not DOS02-LW), cap off the red/yellow wire with a wire connector as it is only used for 3-way connections.

Wiring with a Neutral Wire:

  • Remove the green sleeve from the white wire on the device. Connect this white wire to the white neutral wire(s) in the wall box using a properly sized wire connector.
  • Connect the green and yellow ground lead wire from the device to the ground wire in the wall box using a properly sized wire connector.
  • Connect the black lead wires from the device to the black line and load wires in the wall box. The line and load wires can be wired interchangeably.
  • For DOS05 or DVS05 models (not DOS02-LW), cap off the red/yellow wire with a wire connector as it is only used for 3-way connections.

Video: Leviton's Green Flex Sleeve feature, explaining its use for wiring with or without a neutral wire.

4. デバイスの取り付け

  1. Gently bend the wires and push them into the wall box.
  2. Screw the sensor into the wall box.
  3. Install the wall plate (sold separately).

手術

After installation and restoring power, the sensor will undergo a warm-up period (typically 10-20 seconds). For DOS02-LW, lights will automatically turn on with the first motion detected after the warm-up period. You can also manually press the push pad to turn lights on or off.

Leviton DOS02-LW Motion Sensor Light Switch controlling a single light bulb

Image: The Leviton DOS02-LW Motion Sensor Light Switch demonstrating single pole control of a light.

アプリケーション例ampレ

Examples of where to use the motion sensor switch: mudrooms, closets, and garages

画像: Visual examples of ideal locations for the motion sensor switch, including mudrooms, closets, and garages.

The sensor provides hands-free lighting, which is particularly useful in areas where you may enter with your hands full or where lights are often left on unintentionally.

Graphic illustrating 'Hands-Free Lighting' with a hand icon

Image: A graphic highlighting the 'Hands-Free Lighting' benefit of the motion sensor switch.

プログラミングと設定

The default settings for the sensor are a 10-minute time-out timer, medium range field-of-view, and medium ambient light setting. These settings can be adjusted to suit your specific needs.

Illustration showing hands pressing the motion sensor switch to change settings without tools

Image: The motion sensor switch being pressed to change settings, indicating no tools are required for adjustment.

Refer to the detailed product instruction sheet for specific steps on how to change the time-out timer, sensitivity/coverage, and ambient light settings.

トラブルシューティング

If the lights do not operate as expected after installation, refer to the troubleshooting section in the full instruction sheet. Common issues and adjustments include:

  • Lights do not operate with push pad and RED indicator does not blink when motion is present: Verify wiring connections to the sensor.
  • Lights do not switch ON when motion is detected (DOS02): Motion may be beyond sensing range (move closer to switch). Adjust the light level lower (Option 3, 2, 1 or disable). If the RED light is blinking, it indicates motion. If it is blinking and the load is not turning ON, it could be due to ambient light OR check to make sure that the OCC/VAC switch is in OCC position.
  • Lights always stay ON: Check time delay settings and compare to how long the lights stay ON. Make sure no motion occurs in the coverage area for the time selected by covering the lens. Check that the switch is not installed near a heat source (like stove, lights, heat vents) or detecting motion from an adjacent area (like hallway traffic) and if it is, relocate it.
  • Lights do not turn ON (DVS02): Make sure that control is installed correctly. Make sure the power is ON. Check to make sure the light bulb is functional.

仕様

仕様価値
操作モード自動または手動
現在の評価2 Amps
営業巻tage120ボルト
連絡先の種類通常オープン
コネクタタイプクリンプ
ターミナルワイヤーリード
商品の寸法 (長さ x 幅 x 高さ)1.38 x 1.73 x 4.13インチ
回路タイプ単極
アクチュエータタイプロッカースイッチ
連絡先真鍮
国際保護格付けIP00
ポジション数2
より低い温度定格華氏70度
上限温度定格華氏100度
コントローラータイプモーションセンサースイッチ
制御方法センサー
接続プロトコル赤外線
ワットtage250ワット
アイテム重量0.01オンス

メンテナンス

To clean the device, wipe with a soft, damp 布で拭いてください。研磨剤入りの洗剤や溶剤は使用しないでください。最適な性能を得るには、センサーレンズにほこりや異物が付着していないことを確認してください。

保証とサポート

For warranty information or technical support, please refer to the documentation included with your product or visit the official Leviton webサイト。 保証請求に備えて購入時のレシートを保管しておいてください。

関連文書 - DOS02-LW

前view レビトン DOS05/DVS05 ワイドView モーションアクティベートライトコントロール設置ガイド
Leviton DOS05およびDVS05 Wideの包括的なインストール手順と操作ガイドView モーションアクティベートライトコントロール。配線、プログラミング、検知範囲、トラブルシューティングについて学びます。
前view Leviton DOS05/DVS05 モーションアクティベートライトコントロールの設置と操作
LevitonのDOS05とDVS05 Wideのインストールと操作に関する包括的なガイド View モーション アクティベート ライト コントロールでは、単極および 3 方向のアプリケーション、プログラミング、およびトラブルシューティングについて説明します。
前view Leviton DOS02/DVS02 Motion Activated Light Control Installation and Operation Manual
Detailed instructions for installing and operating Leviton's DOS02 and DVS02 Single Pole Wide View Motion Activated Light Controls, including wiring, programming, and troubleshooting.
前view Leviton DOS15/DVS15 Motion Activated Light Control: Installation and Operation Guide
This guide provides detailed instructions for installing and operating Leviton's DOS15 and DVS15 motion-activated light controls. It covers wiring configurations for single-pole and 3-way setups, programming features like timer, sensitivity, and ambient light, advanced modes, and troubleshooting common issues. Includes diagrams and specifications for optimal use.
前view Leviton ODS15-IDx Designer 壁スイッチ人感センサー設置ガイド
Leviton ODS15-IDx Designer 壁スイッチ占有センサーの包括的なインストール手順とユーザー ガイド。単一および複数の場所のインストールの機能、セットアップ、プログラミング、操作、およびトラブルシューティングを網羅しています。
前view Leviton Smart Wallbox Sensors: Elevate Your Sensing Control Options
Discover Leviton Smart Wallbox Sensors for commercial applications, offering occupancy/vacancy sensing, dimming, switching, energy savings, and code compliance for offices, meeting rooms, and lobbies. Learn about key features and benefits.