リエロ 71300

RIELLO Gulliver BS1 Gas Burner Instruction Manual

ブランド: リエロ | モデル: 71300

1. はじめに

This manual provides essential information for the safe and efficient installation, operation, and maintenance of the Riello Gulliver BS1 1-Stage 16-52 kW Low NOx Gas Burner. Please read this manual thoroughly before attempting any procedures with the burner.

Proper installation, commissioning, and maintenance are crucial for the safe and optimal performance of this device. Adherence to all local and national regulations is mandatory.

2. 安全情報

警告:

  • Installation (gas/water), initial commissioning, and maintenance of this device must only be carried out by a qualified HVAC system mechanic in accordance with valid regulations and these instructions.
  • Failure to comply with safety instructions can result in serious injury, property damage, or death.
  • Ensure the work area is well-ventilated during installation and maintenance.
  • サービスやメンテナンスを行う前に必ず電源を切ってください。

このマニュアルは、将来の参照用に安全な場所に保管してください。

3.製品オーバーview

Riello Gulliver BS1 Gas Burner

Image 1: Riello Gulliver BS1 1-Stage Gas Burner. This image shows the compact, red-cased burner unit with its metallic combustion head.

The Riello Gulliver BS1 is a single-stage monoblock gas burner designed for efficient heating applications. Key features include:

  • シングル-stage monoblock design.
  • Suitable for natural gas, convertible to LPG (liquefied petroleum gas).
  • Fully automatic operation.
  • Flame tube made of stainless steel, resistant to high temperatures.
  • Single-phase electric motor, 230 V, 50 Hz.

4. 仕様

Riello Gulliver BS1 Dimensions and Specifications Table

Image 2: Technical drawing with dimensions and a table of specifications for various Gulliver models, including BS1.

Riello Gulliver BS1 Technical Data
パラメータ 価値
モデル Gulliver BS 1
タイプ 911 T1
パワーレンジ 16~52kW
パワーStages 1
寸法(幅x奥行きx高さ) 234 x 276 x 295 ミリメートル
Flame Tube Length 70~116mm
Flame Tube Diameter 89ミリメートル
認証 CE-0085 AQ 0409
ガス弁 MBDLE 055
繋がり R 1/2 Inch Max.
入口圧力 65 mbar
Multibloc Gas Valve Features Integrated components: Filter, Pressure Regulator, Gas Pressure Monitor (shuts off if minimum gas pressure is not met), Safety Valve, Single-stage Operating Valve with Ignition Gas Flow Control (fast opening) and slow opening of main gas volume.
配線 Ready for plug-in connection.
フランジ Pre-assembled connection flange to the burner.
承認 Joint approval for burner and gas valve.

5. セットアップとインストール

The Riello Gulliver BS1 burner comes with a Multibloc Gas Valve and assembly and operating instructions. It is crucial that installation is performed by a qualified professional.

5.1 インストール前のチェック

  • Verify that the burner model matches the requirements of the heating appliance.
  • Ensure all components listed in the delivery scope are present.
  • Check for any visible damage to the burner or its components.

5.2 Mounting the Burner

Mount the burner securely to the boiler or heating appliance using the pre-assembled connection flange. Ensure a gas-tight seal according to relevant standards.

5.3 ガスと電気の接続

  • Connect the gas supply to the Multibloc Gas Valve (R 1/2 Inch Max. inlet pressure: 65 mbar).
  • Perform a gas leak test after connection.
  • Connect the burner to a 230 V, 50 Hz single-phase electrical supply. The burner is supplied ready for plug-in connection.
  • 適切な接地を確認してください。

5.4 初期試運転

Initial commissioning must be performed by a qualified technician. This involves:

  • Adjusting the burner for optimal combustion based on the heating appliance's requirements.
  • Checking all safety devices and controls.
  • Verifying proper flame detection and ignition sequence.

6. 操作手順

The Riello Gulliver BS1 burner operates automatically once properly installed and commissioned. Users should be aware of the following:

6.1 Starting the Burner

  1. Ensure the heating system is filled and vented.
  2. Turn on the main power supply to the burner.
  3. Set the thermostat or control system to demand heat. The burner will initiate its automatic start-up sequence.

6.2 Shutting Down the Burner

  • To temporarily stop operation, lower the thermostat setting or turn off the heating demand.
  • For extended shutdown or maintenance, turn off the main power supply to the burner at the dedicated switch.
  • For complete system shutdown, close the main gas supply valve.

6.3 エラー表示

The burner is equipped with a control box that indicates operational status and potential faults. Refer to the detailed operating instructions provided with the burner for specific error codes and their meanings.

7. メンテナンス

Regular maintenance is essential for the safe, efficient, and long-lasting operation of your Riello Gulliver BS1 burner. Maintenance must be performed by a qualified HVAC system mechanic.

7.1年次メンテナンス

  • Combustion Analysis: Check and adjust combustion parameters (CO2, O2, CO, flue gas temperature) to ensure optimal efficiency and low emissions.
  • Burner Head and Flame Tube Cleaning: Inspect and clean the burner head, flame tube, and ignition electrodes to remove any soot or deposits.
  • Fan and Air Inlet Cleaning: Clean the fan impeller and air inlet grilles to ensure proper airflow.
  • Gas Valve Inspection: Check the gas valve and associated components for proper operation and leaks.
  • 電気接続: Inspect all electrical connections for tightness and signs of wear.
  • 安全装置: Test all safety devices, including the gas pressure monitor and flame sensor.

7.2 User Checks (Daily/Weekly)

  • Observe the burner's operation for any unusual noises or smells.
  • Check the pressure gauge on the heating system.
  • Ensure the area around the burner is clear of obstructions and flammable materials.

8。 トラブルシューティング

If the burner malfunctions, consult the detailed troubleshooting guide in the original operating instructions. Below are some common issues and general advice:

一般的なトラブルシューティングのシナリオ
問題 考えられる原因 アクション
バーナーが起動しない No power supply, thermostat not calling for heat, safety lockout, gas supply off. Check power, thermostat setting, gas valve. Reset burner if in lockout (refer to manual). If problem persists, contact a qualified technician.
Burner starts but locks out quickly No flame detected, insufficient air/gas mixture, faulty ignition. Do NOT attempt to fix yourself. This requires a qualified technician to inspect and adjust the burner.
異常な音や臭い Combustion issues, mechanical fault, gas leak. Immediately shut off gas supply and power. Ventilate the area. Do NOT attempt to restart. Contact emergency services and a qualified technician.

For any issues beyond simple checks, always contact a qualified and certified HVAC technician. Do not attempt repairs yourself.

9. 保証とサポート

For warranty information, please refer to the documentation provided at the time of purchase or contact your seller. Riello products are known for their quality and reliability.

For technical support, spare parts, or service, please contact your authorized Riello dealer or a qualified HVAC system mechanic. Ensure to provide the model number (71300) and serial number of your burner when seeking support.

You can find more information and contact details on the official Riello webサイト: www.riello.com

関連文書 - 71300

前view Priročnik za namestitv、vzdrževanje gorilnika の uporabo RIELLO Gulliver RG1NR na plinsko olje
文書は、ポドロブナ・ナヴォディラ・ザ・ネームスティテフ、ウポラボ、オドプラヴリャニエ・ナパック・エノストペンジスケガ・ゴリラニカのリエロ・ガリバーRG1NRナ・プリンスコ・オルジェ、vključnos tehničnimi podatki、varnostn​​imi predpisi in postopki zaのvzdrževanjeです。オドプラヴリャニェ・テザヴ。
前view Riello Gulliver RG2F オイルバーナーの部品リストと図
Riello Gulliver RG2F 軽油バーナー (モデル 377T1、コード 3737770) の詳細なスペアパーツ リストとコンポーネント図 (部品番号と英語の説明を含む)。
前view Manuale di Installazione e Manutenzione Bruciatore Gas ad Aria Soffiata RIELLO RS 160/M BLU
Questo documento fornisce istruzioni per l'installazione, l'uso e la manutenzione del bruciatore gas ad aria soffiata RIELLO RS 160/M BLU. Include dati tecnici, specifiche elettriche e guide alla risoluzione dei problemi.
前view Riello 40シリーズ 住宅用オイルバーナー F3 & F5 設置マニュアル
このマニュアルは、Riello 40シリーズ住宅用石油バーナー(モデルF3およびF5)の詳細な設置手順を記載しています。部品の識別、セットアップ、取り付け、電気接続、ノズルの配置、調整手順について説明しています。このマニュアルは改造用途を想定しており、技術データ、仕様、スペアパーツリストが含まれています。
前view リエロ 40 BF シングル Stage 操作オイルバーナー設置および操作マニュアル
Riello 40 BFシングルの包括的な設置および操作マニュアルtag石油バーナーの技術仕様、設置手順、配線図、トラブルシューティング、スペアパーツについて説明します。
前view Riello P 140 P/N 471 M1 重油バーナーの設置およびメンテナンス手順
Riello P 140 P/N 471 M1重油バーナーの設置、使用、メンテナンスに関する包括的な説明書です。技術仕様、電気回路図、燃料供給システム、調整手順を網羅しています。