Leviton LB230-GF

Leviton LB230-GF 30A 2-Pole Plug-On GFCI Branch Circuit Breaker

取扱説明書

導入

This manual provides essential information for the safe and proper installation, operation, and maintenance of your Leviton LB230-GF 30A 2-Pole Plug-On GFCI Branch Circuit Breaker. This device is designed to provide overload and short-circuit protection, featuring an all plug-on design for ease of installation. It incorporates hydraulic magnetic precision trip technology and patented reset lockout technology for enhanced safety and reliability.

安全情報

警告: Risk of electric shock or electrocution. Improper installation or use can result in serious injury or death. Always disconnect power at the main service panel before working with electrical circuits. Installation should only be performed by a qualified electrician in accordance with all national and local electrical codes.

セットアップとインストール

The Leviton LB230-GF circuit breaker features a revolutionary all plug-on design, allowing the entire load center to be wired at rough-in without circuit breakers installed. All hot and neutral wires terminate at custom lugs in the panel, not at the circuit breaker itself.

  1. 電源切断: Before beginning any work, ensure the main power to the electrical panel is completely disconnected. Use a voltagテスターを使用して電源がないことを確認します。
  2. パネルの準備: Ensure the load center is properly wired according to local electrical codes, with hot and neutral wires terminated at the designated custom lugs.
  3. ブレーカーの配置: Identify the appropriate slot in the load center for the 2-pole 30A GFCI breaker.
  4. Plug-On Installation: Align the circuit breaker with the bus bar and firmly press it into place until it is securely seated. The plug-on design ensures a reliable connection.
  5. 配線接続: Connect the load wires to the appropriate terminals on the circuit breaker. Ensure all connections are tight and secure.
  6. Ground and Neutral Connections: Verify that the ground and neutral wires are correctly connected within the panel as per the load center's instructions.
  7. 電力を回復する: Once installation is complete and all connections are verified, close the panel cover and restore power to the main service panel.
Leviton LB230-GF 30A 2-Pole Plug-On GFCI Branch Circuit Breaker

Image: Leviton LB230-GF 30A 2-Pole Plug-On GFCI Branch Circuit Breaker. This image shows the front view of the circuit breaker, highlighting its compact design and terminal connections.

操作手順

The Leviton LB230-GF circuit breaker is designed for intuitive operation and status indication.

メンテナンス

The Leviton LB230-GF circuit breaker requires minimal maintenance. Regular visual inspections are recommended.

トラブルシューティング

回路ブレーカーが落ちた場合は、次の手順に従ってください。

  1. Identify Fault: Observe the LED indicators on the breaker to determine the type of fault (e.g., ground fault, arc fault, overload).
  2. 負荷を切断: Turn off or unplug all appliances and devices connected to the affected circuit.
  3. ブレーカーをリセット: Push the breaker handle completely to the 'OFF' position, then firmly to the 'ON' position.
  4. テスト回路: If the breaker holds, gradually reconnect devices to identify the faulty appliance or overloaded condition.
  5. 持続的なトリップ: If the breaker trips immediately after resetting, or if the LEDs indicate a persistent fault, there may be a wiring issue or a severe fault in the circuit. In such cases, do not attempt further resets. Contact a qualified electrician for diagnosis and repair.
  6. ロックアウトをリセット: If the breaker will not reset, it may be due to the patented reset lockout technology, indicating that ground or arc fault protection is compromised. This is a safety feature. Do not attempt to bypass it. Contact a qualified electrician.

仕様

ブランドレビトン
モデル番号LB230-GF
現在の評価30 Amps
遮断器のタイプGFCI
取り付けタイプパネルマウント
極数2
巻tage120/240ボルトAC
アイテム重量13.6オンス
製品寸法3.1 x 2 x 3.9インチ
材料バイトン

保証

This Leviton LB230-GF circuit breaker is covered by a 10年間の限定保証. For detailed terms and conditions, please refer to the warranty documentation provided with your purchase or visit the official Leviton webサイト。

サポート

For technical assistance, troubleshooting beyond this manual, or warranty claims, please contact Leviton customer support. You can find contact information on the official Leviton webサイトまたは製品のパッケージを通じて入手できます。

Webサイト: www.レビトン.com

関連文書 - LB230-GF

前view Leviton GFNT1-DIN/GFNT2-DIN DINレールマウントGFCIレセプタクル設置ガイド
配線手順、安全上の注意事項、トラブルシューティングなど、Leviton の GFNT1-DIN および GFNT2-DIN DIN レール マウント GFCI レセプタクルのインストールとテストに関する包括的なガイド。
前view Leviton GFCI レセプタクルの設置およびテストガイド
配線手順、安全上の注意事項、トラブルシューティングのヒントなど、Leviton SmartLock Pro GFCI レセプタクルのインストールとテスト方法に関する包括的なガイドです。
前view Leviton ロードセンターエンクロージャの取り付け手順
Levitonロードセンターエンクロージャ(モデルLP2xx、LP3xx、LP4xx、およびLP6xx)の詳細な設置手順書です。安全性、ノックアウトの取り外し、取り付け、配線、分岐回路ブレーカーの取り付け、カバーの取り付けについて説明します。
前view Leviton GFCI コンセント(USB ポート付き)の設置および操作マニュアル
配線手順、安全に関する警告、テスト手順、保証情報など、USB ポート付き Leviton GFCI コンセントのインストールと操作に関する包括的なガイド。
前view Leviton スマート GFCI コンセントの設置とテスト:包括的なガイド
LevitonスマートGFCIコンセント(モデルD2GF1、D2GF2)の設置とテストに関する手順をステップバイステップで解説します。GFCIの機能、配線、トラブルシューティング、安全上の注意事項について解説します。
前view Leviton SmartlockPro GFCI レセプタクルの設置およびテストガイド
Leviton SmartlockPro漏電遮断器(GFCI)レセプタクルの設置とテストに関する包括的なガイドです。安全上の注意事項、配線、トラブルシューティング、製品機能について解説しています。