1. はじめに
This manual provides essential information for the installation, operation, maintenance, and troubleshooting of your HP 658079-B21 2TB 7200RPM 3.5-inch 6G SATA Midline Hard Drive. This drive is designed for use in compatible HP ProLiant servers, including ML350, DL380, and DL360 Gen8 series. Please read this manual thoroughly before proceeding with installation or use to ensure proper functionality and data integrity.
2.製品オーバーview
The HP 658079-B21 is a high-capacity, reliable hard disk drive engineered for server environments requiring a balance of performance and storage capacity. It features a 2TB storage capacity, a rotational speed of 7200 RPM, and a 6Gb/s SATA interface. The 3.5-inch Large Form Factor (LFF) design with an SC (Smart Carrier) is specifically tailored for seamless integration into supported HP ProLiant server systems.

Figure 2.1: HP 658079-B21 2TB SATA Hard Drive mounted in an HP Smart Carrier. This image shows the front view of the drive assembly, including the hot-plug handle and status indicators.
3. 安全情報
- 静電気放電 (ESD) に関する予防措置: Always wear an anti-static wrist strap and work on an anti-static mat when handling the hard drive to prevent damage from static electricity.
- 電源を切る: Ensure the server is completely powered off and disconnected from the power source before installing or removing any internal components.
- 取り扱いにはご注意ください: Hard drives are delicate. Avoid dropping, jarring, or exposing the drive to excessive vibration. Hold the drive by its edges or the carrier.
- 換気: Ensure proper airflow within the server chassis to prevent overheating, which can degrade drive performance and lifespan.
- データのバックアップ: Always back up critical data before performing any hardware changes or maintenance.
4. セットアップとインストール
4.1. インストール前のチェック
- Verify that your server model (e.g., ML350, DL380, DL360 Gen8) supports the HP 658079-B21 hard drive. Consult your server's documentation for compatibility.
- Ensure you have the necessary tools, such as a Phillips head screwdriver (if required for carrier installation) and an anti-static wrist strap.
- Confirm available drive bays in your server.
4.2. 物理的な設置
- パワーダウン: Shut down the server completely and disconnect all power cords.
- アクセスドライブベイ: Open the server chassis or locate the hot-plug drive bay.
- ドライブを挿入: If the drive is not already in a Smart Carrier, install it into an appropriate HP Smart Carrier. Then, slide the HP 658079-B21 hard drive assembly into an empty drive bay until it clicks securely into place. Ensure the drive is fully seated.
- セキュアドライブ: Close the drive bay latch or secure the drive as per your server's design.
- クローズシャーシ: Close the server chassis and reconnect power cords.
- 電源オン: サーバーの電源を入れます。

図4.1:側面 view of the HP 658079-B21 hard drive in its Smart Carrier, illustrating the connection interface and mounting points.
4.3. Initial Configuration (Operating System)
After physical installation, the operating system needs to recognize and prepare the new drive.
- BIOS/UEFI: Access the server's BIOS/UEFI settings to confirm the drive is detected. Ensure the SATA controller is enabled and configured correctly (e.g., AHCI mode for optimal performance).
- オペレーティング·システム:
- ウィンドウズ: Open Disk Management (right-click Start, select Disk Management). The new drive should appear as "Unallocated Space." Initialize the disk (MBR or GPT), create new partitions, and format them (NTFS recommended for Windows).
- リナックス: 次のようなツールを使う
fdisk,parted、 そしてmkfsto partition and format the drive. For exampル、lsblkto identify the drive, thensudo fdisk /dev/sdX(replace X with the drive letter), followed bysudo mkfs.ext4 /dev/sdX1(for the first partition). - RAID 構成: If using a RAID controller, configure the new drive within the RAID controller's utility (either during boot-up or via server management software) before the operating system can see it.

図4.2:上 view of the HP 658079-B21 hard drive, showing the product label with model number, serial number, and other identifying information. This label is crucial for verification and support.
5. ハードドライブの操作
Once installed and configured, the HP 658079-B21 hard drive functions as a standard storage device within your server environment. Its operation primarily involves data storage and retrieval.
- データストレージ: Use the drive for storing operating system files, applications, databases, and user data.
- パフォーマンス: The 7200 RPM speed and 6Gb/s SATA interface provide reliable performance for various server workloads.
- 監視: Utilize server management software (e.g., HP iLO, operating system tools) to monitor drive health, temperature, and performance.
- ホットプラグ機能: If installed in a hot-plug bay, the drive can be removed and replaced while the server is running, provided the operating system and RAID controller support this feature and proper procedures are followed. Always consult your server's documentation for hot-plug procedures.
6. メンテナンス
- 定期的なバックアップ: Implement a robust data backup strategy to protect against data loss due to drive failure or other unforeseen events.
- ドライブの状態を監視する: Regularly check the drive's S.M.A.R.T. (Self-Monitoring, Analysis and Reporting Technology) status using appropriate software. Early detection of potential issues can prevent data loss.
- ファームウェアの更新: HPサポートを定期的にチェックする website for firmware updates for your hard drive and server. Firmware updates can improve performance, stability, and compatibility.
- 環境制御: Maintain a stable operating environment for your server, controlling temperature and humidity within recommended ranges to prolong drive lifespan.
7。 トラブルシューティング
7.1. ドライブが検出されない
- 接続を確認してください: Ensure the drive is fully seated in its bay and the Smart Carrier is properly latched.
- 電源サイクル: Perform a full server power cycle.
- BIOS/UEFI設定: Verify that the SATA controller is enabled in the server's BIOS/UEFI settings.
- RAID Controller: If using a RAID controller, check its configuration utility to see if the drive is detected there. Rebuild or reconfigure as necessary.
- Try Another Bay: 可能であれば、別の正常なドライブ ベイでドライブをテストします。
- Test Another Drive: If possible, test a known-good drive in the same bay to rule out a backplane or controller issue.
7.2. パフォーマンスの問題
- SMARTステータス: Check the drive's S.M.A.R.T. status for any warnings or errors.
- ディスクの断片化: For Windows systems, defragment the drive if it's heavily fragmented.
- ドライバーの更新: Ensure your server's chipset and SATA controller drivers are up to date.
- システムリソース: Check for other system bottlenecks (CPU, RAM, network) that might be impacting drive performance.
- 過熱: Monitor drive temperature. Excessive heat can lead to throttling and reduced performance. Ensure proper server cooling.
7.3. Drive Failure Indicators
- Unusual clicking, grinding, or scraping noises.
- Frequent data corruption or file エラー。
- Operating system failing to boot or recognizing the drive.
- S.M.A.R.T. warnings indicating imminent failure.
If you suspect drive failure, immediately back up any accessible data and consider replacing the drive. Do not attempt to open the hard drive enclosure.
8. 仕様
| 特徴 | 説明 |
|---|---|
| モデル番号 | 658079-B21 |
| 容量 | 2TB(2000GB) |
| インタフェース | SATA 6Gb/秒 |
| 回転速度 | 7200 回転 |
| フォームファクター | 3.5 インチ ラージ フォーム ファクター (LFF) |
| キャリアタイプ | SC (Smart Carrier) |
| 対応デバイス | HP ProLiant ML350, DL380, DL360 Gen8 Servers (and other compatible HP servers) |
| インストールタイプ | 内蔵ハードドライブ |
| 色 | Silver (drive enclosure) |
9. 保証とサポート
This HP hard drive is typically covered by a limited warranty provided by HP or the reseller. The duration and terms of the warranty may vary based on your region and point of purchase. Please retain your proof of purchase for warranty claims.
For technical support, driver downloads, firmware updates, and detailed product information, please visit the official HP Support website and search for your specific model number (658079-B21) or your server model.
- HPサポート Webサイト: https://www.hp.com/support
- 製品ドキュメント: Refer to your server's official documentation for specific installation and configuration details related to your system.