This manual provides essential information for the safe and effective use of your Graco 17P484 HVLP EDGE II Plus Spray Gun. This high-quality, professional-grade spray gun is designed for fine finishes, featuring an ergonomic, lightweight design with a 2-finger trigger. Please read all instructions carefully before operating the equipment.
安全情報
警告: これらの安全に関する指示に従わなかった場合、重大な傷害や物的損害が発生する可能性があります。
- Always wear appropriate safety gear when handling pressurized liquids and chemicals. This includes eye protection, gloves, and respiratory protection as needed.
- スプレー装置は熱源や火気から遠ざけてください。
- スプレーガンを人や動物に向けないでください。
- Ensure adequate ventilation when spraying, especially with solvent-based materials.
- After use, clean the sprayer thoroughly to remove any residual chemicals.
- Store the equipment in a cool, dry place, out of reach of children.
- Always follow the manufacturer's instructions for safe operation and maintenance of all components, including paints and solvents.
製品の特徴とコンポーネント
The Graco 17P484 HVLP EDGE II Plus Spray Gun is designed for versatility and ease of use. Key features include:
- Adjustable Fluid Levels: A dedicated dial allows precise control over fluid output.
- Adjustable Fan Pattern: The fan pattern can be easily adjusted to suit various spraying applications.
- Quick Needle Swap: Designed for rapid and convenient needle changes, enhancing efficiency.
- Versatile Cup Compatibility: Can be used with a traditional 1 qt (0.95 L) metal cup or adapted for turbine pressure cups.
- 人間工学に基づいたデザイン: Lightweight with a 2-finger trigger for comfortable operation.
- 付属品: Comes with a 1 qt (0.95 L) Metal Cup and a #3 Quick Release Fluid Set.

図1: The Graco 17P484 HVLP EDGE II Plus Spray Gun, shown with the attached 1-quart metal cup. This image highlights the gun's ergonomic handle, trigger, and the fluid and fan pattern adjustment points.
設定
- Attach Fluid Cup: Securely attach the 1 qt (0.95 L) metal cup to the spray gun. Ensure it is tightened to prevent leaks. If using a turbine pressure cup, remove the standard fitting and attach the appropriate pressure cup fitting.
- 空気供給を接続する: Connect your air supply hose to the air inlet on the spray gun. The gun is designed for a maximum air pressure of 10 psi.
- Fill with Material: Fill the fluid cup with the desired coating material (varnish, enamel, latex, stains). Ensure the material is properly thinned according to the coating manufacturer's recommendations for HVLP application.
- 初期調整:
- 液面レベル: Use the dial on the gun to set the initial fluid level. Start with a lower setting and increase as needed.
- Fan Pattern: Adjust the fan pattern by turning the air cap. This allows you to switch between horizontal, vertical, and round spray patterns.
操作手順
- テストスプレー: Before applying to your workpiece, perform a test spray on a scrap piece of material to verify the spray pattern and fluid output. Adjust the fluid level and fan pattern as necessary.
- 距離を保つ: 均一な仕上がりを得るために、スプレーガンを表面に対して垂直に持ち、一定の距離(通常は 6 ~ 10 インチ)を保ちます。
- 一貫した動き: Use smooth, overlapping passes. Release the trigger at the end of each pass to avoid excessive material buildup.
- トリガーコントロール: The 2-finger trigger allows for comfortable and controlled application.
メンテナンス
適切なメンテナンスを行うことで、スプレーガンの寿命が長くなり、最適なパフォーマンスが確保されます。
- 使用後の洗浄:
- カップに残っている材料をすべて取り除きます。
- Fill the cup with an appropriate cleaning solvent (water for latex, mineral spirits for oil-based paints, etc.).
- 溶剤が透明になるまでガンを通して溶剤をスプレーします。
- Disassemble the air cap and fluid tip, cleaning them thoroughly with a brush and solvent.
- Wipe down the exterior of the gun.
- 針の交換: The needles can be swapped quickly. To replace, twist off the front section of the gun, push the release mechanism, and pull the needle out. Insert the new needle and reassemble. This process typically takes less than a minute.
- ストレージ: Store the clean and dry spray gun in a safe place to prevent damage.
トラブルシューティング
スプレーガンで問題が発生した場合は、次の一般的な解決策を検討してください。
- スプレーパターンが悪い: Check for clogged fluid tip or air cap. Ensure material is properly thinned. Verify air pressure is adequate (max 10 psi).
- No Material Flow: Check if the fluid cup is empty or if the fluid tube is clogged. Ensure the fluid needle is not stuck.
- リーク: Inspect all connections for tightness. Check for damaged O-rings or seals and replace if necessary.
- 不均一なスプレー: Ensure consistent air pressure. Check for blockages in the fluid path or air passages.
For persistent issues, contact Graco customer support or a certified service center.
仕様
| 特徴 | 詳細 |
|---|
| ブランド | グラコ |
| モデル番号 | 17P484 |
| 銃の種類 | HVLP Gun |
| Gun Activation | マニュアル |
| 適合材料 | Varnish, Enamel, Latex, Stains |
| 最大空気圧 | 10平方インチあたりXNUMXポンド |
| Included Cup Volume | 1 qt (0.95 L) Metal Cup |
| アイテム重量 | 3.04 ポンド (1.38 キログラム) |
| 電源 | エアパワード |
| 欧州連合 | 755652419242 |