シンプレックス 4099-9005

Simplex 4099-9005 Addressable Manual Pull Station (Dual Action) User Manual

モデル:4099-9005

1. はじめに

The Simplex 4099-9005 is an addressable manual pull station designed for use with compatible Simplex fire alarm control panels. This dual-action device requires two distinct operations to activate, reducing the likelihood of accidental activation. It is an integral component of a comprehensive fire detection and alarm system, providing a manual means for occupants to initiate an alarm in the event of a fire or other emergency.

2. 安全情報

重要な安全上の注意事項:

3.製品オーバーview

The Simplex 4099-9005 is a red, dual-action manual pull station. Its addressable nature allows the fire alarm control panel to identify the exact location of the activated station. The dual-action design requires a two-step process for activation: first, pushing in a bar, and then pulling down a handle.

フロント view of the Simplex 4099-9005 Addressable Manual Pull Station, showing the 'FIRE ALARM' label, 'PUSH BAR', and 'PULL HANDLE'.

図1: 前面 view of the Simplex 4099-9005 Addressable Manual Pull Station. This image displays the primary components including the 'FIRE ALARM' text, the 'PUSH BAR' mechanism, and the 'PULL HANDLE' for activation.

4. インストール

Proper installation is crucial for the reliable operation of the manual pull station.

4.1 取り付け

4.2配線

4.3 アドレス設定

The 4099-9005 is an addressable device. Before connecting to the SLC, set the unique address for the pull station using the appropriate Simplex programming tool or DIP switches, as specified in the device's technical documentation. Each device on the SLC must have a unique address.

側 view of the Simplex 4099-9005 Addressable Manual Pull Station, showing its depth and mounting points.

図2:側面 view of the Simplex 4099-9005 Addressable Manual Pull Station. This image illustrates the depth of the unit and provides a perspective on its mounting configuration.

5. 操作

5.1 アラームの起動

In the event of a fire or emergency, follow these steps to activate the manual pull station:

  1. 押し込む: Firmly push the bar labeled "PUSH BAR" on the front of the station.
  2. プルダウン: Once the bar is pushed in, pull down the handle labeled "PULL HANDLE" until it latches in the down position.

Activation will send an alarm signal to the fire alarm control panel, initiating the building's alarm sequence.

5.2 プルステーションのリセット

After an alarm has been activated and the emergency resolved, the pull station must be reset. The Simplex 4099-9005 requires a B-Key for resetting.

  1. Insert B-Key: Locate the keyhole on the front of the pull station. Insert the B-Key into the keyhole.
  2. ターンキー: Turn the B-Key clockwise or counter-clockwise (depending on the specific mechanism) to release the latched handle.
  3. カバーを閉じる: Return the handle to its original, unactivated position and close the front cover.
  4. Remove B-Key: Remove the B-Key.

The B-Key is considered a tool for maintenance and resetting, not a consumable item. If additional B-Keys are required, they can be ordered using PID: 252-019.

6. メンテナンス

Regular maintenance ensures the continued reliability of your Simplex 4099-9005 pull station.

7。 トラブルシューティング

If you encounter issues with your Simplex 4099-9005 pull station, consider the following:

For persistent issues, contact a qualified fire alarm technician.

8. 仕様

特徴仕様
ブランドシンプレックス
モデル番号4099-9005
スタイル安全性
電源マニュアル
アイテム重量3.53オンス(100グラム)
アラームタイプAudible (via FACP)
材料Glass (referring to break-glass type, though this model is dual-action)
製品寸法1 x 3.4 x 5インチ
欧州連合643485652991
部品番号S4099-9005
電池が必要いいえ

9. 保証情報

Specific warranty details for the Simplex 4099-9005 Addressable Manual Pull Station are typically provided at the point of purchase or can be obtained directly from Simplex or an authorized distributor. Please retain your proof of purchase for warranty claims. For detailed warranty terms and conditions, refer to the official Simplex documentation or contact their customer service.

10. カスタマーサポート

For technical assistance, installation queries, or service requests, please contact your authorized Simplex dealer or a certified fire alarm technician. Ensure you have the product model number (4099-9005) and any relevant system information available when seeking support.