1. はじめに
This manual provides essential instructions for the installation, operation, and maintenance of the Cisco UCS C240 M3 High-Density Rack-Mount Server. The Cisco UCS C240 M3 is a 2-socket, 2U rack server designed for a broad range of workloads, offering high performance and expandability. Please read this manual thoroughly before proceeding with any operations to ensure proper handling and to prevent damage to the equipment or injury to personnel.
2. 安全情報
Observe the following safety precautions to minimize the risk of injury and to prevent damage to the server:
- Always disconnect all power cords from the server before performing any maintenance or installation procedures.
- Ensure proper grounding of the server and the rack.
- Do not operate the server with covers removed unless specifically instructed to do so for maintenance.
- Use appropriate lifting techniques when installing or removing the server from a rack due to its weight (approximately 54.7 pounds).
- 過熱を防ぐために、サーバーの周囲に適切な換気を確保してください。
- インストールとメンテナンスは資格のある担当者のみが行う必要があります。
3. パッケージ内容
Verify that all components are present and undamaged upon unpacking. The standard package for the Cisco UCS C240 M3 server typically includes:
- Cisco UCS C240 M3 Rack Server unit
- Rack mounting rail kit
- Power cords (region-specific)
- Documentation (Quick Start Guide, Safety and Compliance Information)
- Optional components such as hard drives, memory modules, and expansion cards, if ordered.
If any items are missing or damaged, contact your Cisco representative or reseller immediately.
4. フィジカルオーバーview
This section provides a visual guide to the external components of the Cisco UCS C240 M3 server.
4.1フロントパネル

図4.1: フロント view of the Cisco UCS C240 M3 server. This image displays the front panel of the server, featuring 24 small form factor (SFF) hot-swappable drive bays, status LEDs, and control buttons on the left and right ears.
The front panel provides access to the hot-swappable drive bays, system status indicators, and control buttons. The C240 M3 supports up to 24 SFF 2.5-inch drives.
4.2 背面パネル

図4.2: 後方 view of the Cisco UCS C240 M3 server. This image illustrates the rear panel, including redundant hot-swappable power supplies, multiple Gigabit Ethernet ports, USB ports, a VGA port, and PCIe expansion slots.
The rear panel houses the power supply units, network interfaces, and various I/O ports. It typically includes:
- Redundant hot-swappable power supply units (e.g., 1200W AC).
- Gigabit Ethernet ports for network connectivity.
- USB ports for peripheral connections.
- VGA port for console display.
- Serial port (DB-9).
- PCIe expansion slots for additional adapters.
4.3 トップ/サイド View

図4.3: 斜めのトップフロント view of the Cisco UCS C240 M3 server. This image provides a perspective of the server's chassis, highlighting its 2U rack-mountable form factor and overall design.
これ view illustrates the overall 2U rack-mountable form factor of the server, designed for high-density environments.
5. セットアップ
Follow these steps to properly set up your Cisco UCS C240 M3 server.
5.1 ラックへの設置
- ラックを準備する: Ensure the rack is stable and has adequate space for a 2U server.
- レールキットの取り付け: Attach the provided rail kit to the rack posts according to the instructions included with the rail kit.
- サーバーをマウントします。 Carefully slide the server onto the installed rails until it clicks into place. Secure the server to the rack using the provided screws.
5.2 周辺機器の接続
- 力: Connect the power cords from the server's power supply units to separate, grounded power outlets or a power distribution unit (PDU).
- ネットワーク: Connect Ethernet cables from the server's network ports to your network switch.
- Console (Optional): For initial setup or direct access, connect a monitor to the VGA port and a keyboard/mouse to the USB ports on the rear panel.
5.3初期電源オン
- すべての接続が安全であることを確認します。
- フロントパネルの電源ボタンを押します。
- 正常な動作については、システム ステータス LED を観察します。
- Access the Cisco Integrated Management Controller (IMC) via a web browser using the server's management IP address for further configuration. Refer to the Cisco UCS C-Series Servers Integrated Management Controller GUI Configuration Guide for detailed instructions.
6. サーバーの操作
This section covers basic operational procedures for the Cisco UCS C240 M3 server.
6.1 Power On/Off Procedures
- 電源オン: Press the power button on the front panel. The system will initiate its boot sequence.
- 通常シャットダウン: From the operating system, perform a graceful shutdown. Once the OS has shut down, the server will power off automatically.
- 強制シャットダウン: In an emergency, press and hold the power button for more than 4 seconds. This should only be used as a last resort to prevent data corruption.
6.2 Accessing Cisco IMC
The Cisco Integrated Management Controller (IMC) provides a web-based interface for server management. To access it:
- Ensure the server's management port is connected to the network.
- Obtain the IP address assigned to the IMC (either through DHCP or manual configuration during initial setup).
- 開く web browser and enter the IMC's IP address.
- 資格情報を使用してログインします。
6.3 オペレーティングシステムのインストール
Operating system installation can be performed via the Cisco IMC's KVM console, virtual media, or by booting from a physical optical drive or USB device connected to the server. Consult your chosen operating system's installation guide for specific steps.
7. メンテナンス
Regular maintenance ensures optimal performance and longevity of your server.
7.1 ホットスワップ可能なコンポーネント
The Cisco UCS C240 M3 features hot-swappable components, allowing replacement without powering down the server. These include:
- ハードドライブ: Drives can be removed and inserted from the front panel. Always ensure data is backed up and the drive is properly unmounted from the operating system before removal.
- 電源: Redundant power supplies can be replaced individually from the rear panel.
- ファン: Fan modules are typically hot-swappable and accessible from the top cover.
Refer to the Cisco UCS C240 M3 Server Installation and Service Guide for detailed instructions on replacing specific components.
7.2 クリーニング
Periodically inspect the server for dust accumulation, especially around air vents and fan inlets/outlets. Use compressed air to gently clean dust from internal components and external surfaces. Ensure the server is powered off and disconnected from power before cleaning internal components.
7.3ファームウェアアップデート
シスコサポートを定期的にチェックする website for firmware updates for the server, RAID controller, and other components. Firmware updates can provide performance enhancements, bug fixes, and security improvements. Follow Cisco's recommended procedures for applying firmware updates.
8。 トラブルシューティング
This section provides guidance for resolving common issues.
8.1 LEDインジケーター
The server's front panel and individual components (e.g., power supplies, drives) feature LED indicators that provide status information. Consult the Cisco UCS C240 M3 Server Installation and Service Guide for a comprehensive list of LED patterns and their meanings.
- システムステータス LED: Indicates overall server health (e.g., green for normal, amber for warning, red for critical).
- 電源LED: Indicate power supply status (e.g., green for operational, amber for fault).
- 駆動LED: Indicate drive activity, status, and fault conditions.
8.2 一般的な問題と解決策
- 電源なし:
- Verify power cords are securely connected to the server and power source.
- Check power supply LEDs.
- 電源がアクティブであることを確認します。
- ネットワーク接続の問題:
- イーサネット ケーブルの接続を確認してください。
- ネットワーク スイッチ ポートのステータスを確認します。
- Confirm IP configuration in the operating system or IMC.
- ドライブエラー:
- Check drive LEDs for fault indications.
- Consult RAID controller utility for drive status.
- Replace faulty drives as per maintenance procedures.
8.3 サポートへの連絡
If you encounter issues that cannot be resolved using this guide, contact Cisco Technical Support. Have your server's serial number and a description of the problem ready.
9. 仕様
Key technical specifications for the Cisco UCS C240 M3 High-Density Rack-Mount Server:
| 特徴 | 詳細 |
|---|---|
| モデル番号 | UCSC-C240-M3S-CH2 |
| フォームファクター | Rack-mountable, 2U |
| プロセッサーのサポート | 2-way (Dual Processor Capable) |
| Memory (Base) | 0 MB (Configurable) |
| ストレージインターフェース | SATA/SAS, Hot-swap 2.5" bays |
| グラフィックコントローラー | G200e |
| ネットワークコントローラ | ギガビットLAN |
| モニター | None (External connection via VGA) |
| 製品寸法 | 39.7 x 24.1 x 10インチ |
| アイテム重量 | 54.7ポンド |
| バッテリー | 製品固有の電池が必要です。 |
| 初回利用可能日 | 1年2013月XNUMX日 |
10. 保証とサポート
For detailed information regarding the product warranty, service agreements, and technical support options, please refer to the official Cisco website or contact your authorized Cisco reseller. Warranty terms and conditions may vary based on region and purchase agreement.
Cisco Support Resources:
- オンラインドキュメント: Access comprehensive guides and manuals on the Cisco Support webサイト。
- Technical Assistance Center (TAC): For technical issues, contact Cisco TAC.
- ソフトウェアのダウンロード: Obtain the latest drivers, firmware, and software from the Cisco webサイト。