Dante NG.BVS.CR

Dante Products NG.BVS.CR ユニバーサルログライターコンボキット ユーザーマニュアル

Model: NG.BVS.CR

導入

This manual provides comprehensive instructions for the safe and efficient installation, operation, and maintenance of the Dante Products NG.BVS.CR Universal Log Lighter Combo Kit. This kit is designed to provide a convenient and clean method for igniting natural gas logs in a fireplace.

設置およびご使用の前に、すべての説明書をよくお読みください。このマニュアルは、今後の参考のために保管してください。

製品構成

The Dante Universal Log Lighter Combo Kit includes the following components:

Dante Products NG.BVS.CR Universal Log Lighter Combo Kit components: a chrome key, a chrome floor plate, a long gas log lighter tube with a mixer, and a brass T-fitting.

図1: 以上view of the Dante Universal Log Lighter Combo Kit components. This image displays all parts included in the kit: a chrome-plated key for operating the valve, a circular chrome floor plate that covers the valve opening, a long metal tube which is the natural gas log lighter with an attached mixer at one end, and a brass T-fitting for gas line connection.

  • Natural Gas Log Lighter: A 20-inch long tube with an integrated air/gas mixing chamber, designed for efficient gas combustion.
  • Quarter-Turn Ball Valve: A straight 1/2-inch valve for controlling gas flow.
  • Chrome Floor Plate: A decorative zinc die-cast, chrome-plated plate to cover the valve opening.
  • 3-Inch Key: A zinc die-cast, chrome-plated key for operating the quarter-turn ball valve.
  • Brass T-Fitting: For connecting the gas supply line.

セットアップとインストール

重要な安全情報: Installation must be performed by a qualified professional in accordance with all local codes and regulations. Ensure the main gas supply is turned off before beginning installation.

  1. Prepare Fireplace: Ensure the fireplace is clean and free of debris. Identify the location for the gas line connection.
  2. ガス管を接続する: Connect the natural gas supply line to the brass T-fitting. Use appropriate pipe sealant on all threaded connections to prevent leaks.
  3. Install Ball Valve: Attach the quarter-turn ball valve to the T-fitting. Ensure it is securely tightened.
  4. Position Log Lighter: Connect the natural gas log lighter tube to the ball valve. Position the log lighter within the fireplace, ensuring the burner holes face upwards and are clear of any obstructions. The log lighter measures 20 inches from end to end with the mixer attached.
  5. Install Floor Plate: Place the chrome floor plate over the valve stem opening in the hearth or floor, ensuring it sits flush.
  6. 漏れのテスト: After all connections are made, slowly turn on the main gas supply. Apply a leak detection solution (soapy water) to all connections. Bubbles indicate a leak. If a leak is detected, turn off the gas supply immediately, tighten connections, and re-test. Do not proceed until all leaks are resolved.
  7. Place Gas Logs: Arrange your gas logs over the log lighter, ensuring they do not block the burner holes or the air/gas mixing chamber. Allow adequate air circulation around the log lighter.

操作手順

安全第一: Always ensure proper ventilation when operating gas appliances. Never leave an active flame unattended.

  1. Open Dampえー: Ensure the fireplace damper is fully open before lighting to allow for proper ventilation and prevent smoke from entering the room. The log lighter heats the chimney quickly, causing the fireplace to draw smoke immediately up the chimney.
  2. 挿入キー: Insert the 3-inch chrome key into the quarter-turn ball valve stem.
  3. Turn On Gas: Slowly turn the key to the "ON" position (typically a quarter-turn). You should hear the sound of gas flowing.
  4. Ignite Gas: Immediately use a long fireplace lighter or match to ignite the gas flowing from the log lighter. The flame should be visible and consistent.
  5. 炎を調整: Once the logs are ignited, you can adjust the flame intensity by partially turning the key towards the "OFF" position. For full ignition of logs, allow the log lighter to burn for a few minutes until the logs are sufficiently lit.
  6. Turn Off Log Lighter: Once the gas logs are burning steadily, turn the key to the "OFF" position to extinguish the log lighter flame. Remove the key.

メンテナンス

The Dante Universal Log Lighter Combo Kit requires minimal maintenance. Regular inspection is recommended to ensure safe and efficient operation.

  • 年次検査: Have a qualified professional inspect the gas connections and the log lighter annually for any signs of wear, corrosion, or leaks.
  • Clean Burner Holes: Periodically check the burner holes on the log lighter tube for any obstructions (e.g., soot, debris). Use a small brush or wire to clear them if necessary. Ensure the gas supply is off before cleaning.
  • コンポーネントをクリーンにします: Wipe down the chrome floor plate and key with a soft, damp cloth to maintain their appearance. Avoid abrasive cleaners.

トラブルシューティング

問題 考えられる原因 解決
No gas flow or weak flame.
  • 主ガス供給がオフになっています。
  • Valve not fully open.
  • ガス管の閉塞。
  • Check main gas supply valve.
  • キーが完全に「ON」になっていることを確認してください。
  • Contact a qualified technician to inspect gas lines.
ガスの臭いが検出されました。
  • Gas leak at connections.
  • バルブが完全に閉じていません。
  • Immediately turn off gas supply. Ventilate area. Apply leak detection solution to all connections. Tighten or repair as needed. If smell persists, evacuate and call gas company.
  • Ensure key is fully turned to "OFF" and removed.
Log lighter does not ignite.
  • No gas flow (see above).
  • Ignition source not applied quickly enough.
  • Burner holes obstructed.
  • Follow steps for "No gas flow".
  • Apply ignition source immediately after turning on gas.
  • Clean burner holes (ensure gas is off).

トラブルシューティング手順を実行しても問題が解決しない場合は、資格のあるサービス技術者に連絡してください。

仕様

モデル番号 NG.BVS.CR
ブランド Dante Products
燃料の種類 天然ガス(NG)
Log Lighter Length 20 inches (end to end with mixer)
BTU評価 30,000BTU
バルブサイズ 1/2-inch (straight quarter-turn ball valve)
Material (Key & Floor Plate) Zinc Die-Cast, Chrome Plated
全体寸法 24 x 3 x 3インチ
アイテム重量 3 ポンド
組み立てが必要 はい
電池が必要 いいえ

保証情報

The Dante Products NG.BVS.CR Universal Log Lighter Combo Kit comes with a 限定1年保証 購入日より。

This warranty covers defects in materials and workmanship under normal use. It does not cover damage resulting from improper installation, misuse, abuse, accident, neglect, or unauthorized repairs. For warranty claims, please retain your proof of purchase and contact Dante Products customer support.

カスタマーサポート

For technical assistance, replacement parts, or warranty inquiries, please contact Dante Products customer support.

Please have your model number (NG.BVS.CR) and proof of purchase available when contacting support.

For additional information and resources, you may visit the official Dante Products website (if available, link would be here).

メーカー: Dante Products

関連文書 - NG.BVS.CR

前view Dante電気暖炉ヒーターの取扱説明書と設置ガイド
Dante フラット パネル電気暖炉ヒーター (モデル EFW-TJ42A) の包括的なオーナーズ マニュアルおよびインストール ガイド。安全性、操作、組み立て、トラブルシューティングについて説明しています。
前view DanteトラブルシューティングFAQ:一般的なオーディオネットワークの問題に対する解決策
この包括的なFAQガイドでは、DanteコントローラーやDanteバーチャルサウンドカードを含むDanteオーディオネットワークで発生する一般的な問題に対する解決策と解説を提供しています。デバイスの表示、オーディオの歪み、クロック同期などに関する問題の解決方法を学びましょう。
前view Dante 2CH USBオーディオエンコーダー/デコーダー(POE対応): ユーザーマニュアルと仕様
Dante 2CH USBオーディオエンコーダー/デコーダー(POE対応)の包括的なユーザーマニュアル。機能、仕様、操作、アプリケーション例などについて解説します。ampプロフェッショナルオーディオネットワーク用ファイル。
前view Dante 2CHアナログオーディオエンコーダー(POE対応)|ユーザーマニュアルと仕様
Dante 2CHアナログオーディオエンコーダ(POE付き)のユーザーマニュアル。機能、仕様、操作、アプリケーションの詳細を説明しています。ampプロフェッショナルオーディオネットワーク用ファイル。
前view DANTE DMIC 3 Dante Microphone Specifications and Features
Detailed specifications and features of the DANTE DMIC 3 Dante microphone, including directivity, frequency response, power supply, and dimensions. Learn about its PoE capabilities and Dante network integration for professional audio applications.
前view Dante AVIO Install: 2-Channel Analog Adapters for Pro AV Integrators
Discover the Dante AVIO Install line of 2-channel analog adapters, designed for seamless integration of analog audio equipment into Dante-enabled Pro AV systems. Learn about features like Euroblock terminals, the ClickGrid mounting system, and superior audio performance.