Allen-Bradley 1746-P2

Allen-Bradley 1746-P2 SLC 500 電源装置の取扱説明書

1. はじめに

This manual provides essential information for the safe and effective installation, operation, and maintenance of the Allen-Bradley 1746-P2 SLC 500 Power Supply. The 1746-P2 is designed to provide reliable power to the SLC 500 programmable controller system, ensuring stable performance for industrial automation applications.

Please read this manual thoroughly before attempting to install or operate the unit. Retain this document for future reference.

2. 安全情報

警告: Electrical shock hazard. Always disconnect power before installing, removing, or wiring modules in the racks. Never operate any module selector switch while the circuit is energized. Failure to follow these instructions may result in serious injury or death.

Observe all local and national electrical codes. Installation and maintenance should only be performed by qualified personnel.

トップ view of Allen-Bradley 1746-P2 Power Supply with warning label

図2.1:上 view of the 1746-P2 Power Supply, showing the Allen-Bradley branding and a critical safety warning label regarding live circuits.

  • システムの接地が適切であることを確認してください。
  • Use only specified fuse types and ratings for replacement.
  • Use copper wire rated for 75°C or higher for all connections.

3.製品オーバーview

The Allen-Bradley 1746-P2 is a power supply module designed for use with the SLC 500 chassis. It converts incoming AC line voltage into the necessary DC voltages required to power the SLC 500 processor and I/O modules within the rack. This module is part of Series C, indicating its revision level.

Allen-Bradley 1746-P2 Power Supply mounted in an SLC 500 rack

Figure 3.1: The Allen-Bradley 1746-P2 Power Supply shown connected to an SLC 500 chassis, illustrating its typical installation configuration.

Detailed product label of Allen-Bradley 1746-P2 Power Supply

図3.2: クローズアップ view of the product label on the 1746-P2 Power Supply, displaying model number, serial number, and electrical specifications.

4. インストール

The 1746-P2 power supply is designed for direct mounting into any slot of an SLC 500 chassis. Ensure the chassis is securely mounted in its intended location before installing the power supply.

4.1 取り付け手順

  1. Ensure all power to the SLC 500 chassis is disconnected and locked out.
  2. Align the 1746-P2 module with an available slot in the SLC 500 chassis.
  3. Slide the module firmly into the slot until it is fully seated and the locking mechanism engages.
  4. Verify that the module is securely fastened to the chassis.
底 view of Allen-Bradley 1746-P2 Power Supply and rack with interconnect cable

図4.1:下 view of the 1746-P2 Power Supply and an SLC 500 rack, showing the interconnect cable (1746-C7) which links the power supply to the backplane.

Close-up of Allen-Bradley 1746-C7 Rack Interconnect cable

図4.2: 詳細な view of the 1746-C7 Rack Interconnect cable, essential for connecting the power supply to the SLC 500 backplane.

5.配線

Proper wiring is critical for the safe and reliable operation of the 1746-P2 power supply. Refer to the product label for specific terminal designations and voltag要件。

5.1 入力電源接続

  • The 1746-P2 accepts two ranges of AC input voltage: 85-132 VAC or 170-265 VAC.
  • The operating frequency is 50/60 Hz.
  • Connect the incoming AC power lines to the designated input terminals on the power supply. Ensure correct phase and neutral connections as per local electrical codes.
  • Always use 75°C rated copper wire for all power connections.

5.2 出力電力

The power supply provides the following DC outputs to the SLC 500 backplane:

  • 5 VDC 5 Ampエルス
  • 24 VDC 0.96 Ampエルス
  • User 24 VDC at 0.2 Ampエルス
Close-up of Allen-Bradley 1746-P2 Power Supply label showing voltageおよび出力仕様

図5.1:詳細 view of the power supply label, highlighting the input line voltage requirements and the various DC output specifications.

6. 操作

Once the 1746-P2 power supply is correctly installed and wired, apply the specified AC input voltage. The power supply will automatically convert and distribute the necessary DC voltages to the SLC 500 backplane, powering the processor and I/O modules. There are no user-adjustable controls on the power supply module itself for normal operation.

Refer to the SLC 500 processor and I/O module manuals for specific operational details of the overall system.

7. メンテナンス

Routine maintenance helps ensure the longevity and reliability of the 1746-P2 power supply.

7.1 検査

  • Periodically inspect the power supply and its connections for any signs of damage, loose wiring, or excessive dust accumulation.
  • 過熱を防ぐために、通気口に障害物がないことを確認してください。
Close-up of the ventilation grille on the Allen-Bradley 1746-P2 Power Supply

図7.1: クローズアップ view of the ventilation grille on the 1746-P2 Power Supply, emphasizing the importance of keeping these areas clear for proper cooling.

7.2 クリーニング

If cleaning is necessary, disconnect all power to the unit. Use a soft, dry cloth or a low-pressure air duster to remove dust and debris. Do not use liquid cleaners or solvents.

7.3 ヒューズの交換

If a fuse requires replacement, ensure power is disconnected. The specified fuse replacement is a 250V 3A FUSE (SANO SOC SD4 or BUSSMANN AGC 3). Always replace with a fuse of the identical type and rating.

8。 トラブルシューティング

This section provides basic troubleshooting steps for common issues. For complex problems, contact qualified technical support.

8.1 No Power to SLC 500 System

  • 入力電源を確認してください: Verify that the correct AC line voltage (85-132 VAC or 170-265 VAC, 50/60 Hz) is supplied to the power supply terminals.
  • ヒューズを確認してください: Inspect the internal fuses of the power supply. If a fuse is blown, replace it with the specified type (250V 3A FUSE, SANO SOC SD4 or BUSSMANN AGC 3).
  • モジュール座席: Ensure the 1746-P2 module is fully seated in the SLC 500 chassis slot.
  • 相互接続ケーブル: Verify the 1746-C7 interconnect cable is properly connected between the power supply and the backplane.

8.2 System Instability or Errors

  • 巻tage出力: While not user-adjustable, ensure the power supply is providing stable output voltages (5VDC, 24VDC). This may require specialized test equipment.
  • オーバーロード: Check if the total current draw from the SLC 500 modules exceeds the power supply's capacity.
  • 環境要因: Ensure the operating temperature is within the specified range and there is adequate ventilation.

9. 仕様

パラメータ仕様
モデル番号1746-P2
シリーズC
入力ボリュームtage範囲85-132 VAC または 170-265 VAC
入力周波数50/60Hz
Output 1 (5 VDC)5 Ampエルス
Output 2 (24 VDC)0.96 Ampエルス
Output 3 (User 24 VDC)0.2 Ampエルス
ヒューズの交換250V 3A FUSE (SANO SOC SD4 or BUSSMANN AGC 3)
推奨線種75°C Copper Wire
製品寸法(長さ x 幅 x 高さ)6 x 6 x 3.5インチ
重さ1.35 ポンド
Operating Temperature CodeT3C
Hazardous Location RatingClass 1, Groups A, B, C and D, Div 2

10. 保証とサポート

Warranty information for the Allen-Bradley 1746-P2 Power Supply is typically provided at the point of purchase or through official Allen-Bradley (Rockwell Automation) channels. Please refer to your purchase documentation or contact your supplier for specific warranty terms and conditions.

For technical support, service, or additional product information, please contact Allen-Bradley (Rockwell Automation) directly or an authorized distributor. Their official website often provides comprehensive resources, including updated manuals, software, and contact information for support services.

関連文書 - 1746-P2

前view アレン・ブラッドリーのパネルView オペレータ端末ユーザーマニュアル
このユーザーマニュアルは、Allen-Bradleyパネルに関する包括的な情報を提供します。View オペレータターミナルについて、その用途、種類、機能、構成、用途、設置、トラブルシューティングを網羅しています。パネルを含む様々なモデルの詳細も記載しています。View 550、600、900、1000、1400。
前view SLC 500 Hardware Migration Guide: Upgrade to CompactLogix
This guide provides comprehensive instructions for migrating from SLC 500 hardware to newer Allen-Bradley CompactLogix and Compact 5000 I/O systems. It covers controller and I/O module replacements, including wiring diagrams and software requirements for a smooth transition.
前view SLCからCompactLogixへのプログラミング移行ガイド - Rockwell Automation
A comprehensive guide for migrating SLC programs and I/O to CompactLogix systems, detailing the process, requirements, and considerations for a smooth transition. This document provides insights into leveraging existing infrastructure while minimizing costs and risks.
前view MicroLogix 1200 16ポイントDC入力モジュールの取り付け手順
Comprehensive installation guide for the Allen-Bradley MicroLogix 1200 16-point DC Input Module (1762-IQ16), covering mounting, wiring, specifications, and safety precautions for industrial environments.
前view Allen-Bradley MicroLogix 1762-OB32T Solid State 24V DC Source Output Module Installation Instructions
Detailed installation instructions for the Allen-Bradley MicroLogix 1762-OB32T Solid State 24V DC Source Output Module. Covers safety information, environmental considerations, mounting procedures, wiring diagrams, I/O addressing, specifications, and Rockwell Automation support resources.
前view 1746 SLC I/O to Compact 5000 I/O Conversion System Selection Guide
This guide provides information on selecting and installing the 1746 SLC I/O to Compact 5000 I/O Conversion System from Allen-Bradley. It details conversion modules, chassis, and wiring diagrams.