フルーク TL175

Fluke TL175 TwistGuard テストリード ユーザーマニュアル

モデル: TL175

1. はじめに

The Fluke TL175 TwistGuard Test Leads are designed for electrical measurement applications, offering enhanced safety and versatility. These test leads feature an adjustable tip shroud mechanism and a WearGuard lead wire wear indication system, ensuring reliable performance and user safety across various measurement environments. They are compatible with all instruments that accept standard 4mm shrouded banana plugs.

2. 安全情報

WARNING: To prevent possible electrical shock, fire, or personal injury:

  • Always use the test leads with the appropriate safety category rating for the measurement environment.
  • Inspect test leads for damage before each use. Do not use if insulation is damaged or if the inner contrasting color of the WearGuard system is exposed.
  • Ensure the test lead tips are fully inserted into the measurement device.
  • 定格容量を超えて塗布しないでくださいtage, as marked on the test leads.
  • Keep fingers behind the finger guards on the probes during measurements.
  • ボリュームを扱うときは注意してくださいtages above 30 V AC RMS, 42 V peak, or 60 V DC. These voltag感電の危険があります。

3 製品の特徴

  • TwistGuard Extendable Tip Shroud: Patented design allows users to twist the probe handle to extend or retract the tip shroud, reducing tip exposure for higher safety categories (CAT III, CAT IV) and providing full tip exposure for lower categories (CAT II).
  • WearGuard Lead Wire Indication: Each test lead features two layers of silicone insulation. If the outer layer is nicked or scuffed, the inner contrasting color becomes visible, indicating the need for replacement.
  • Double Insulated Silicone Leads: Designed to withstand high temperatures and maintain flexibility in cold conditions.
  • Extra-Heavy Duty Strain Relief: Reinforced strain relief on both probe-end and plug-end for enhanced durability, tested beyond 30,000 bends.
  • Universal Input Plugs: Compatible with all instruments that accept standard 4mm shrouded banana plugs.
  • Removable 4mm Lantern Tips: Includes removable tips that thread onto the lead tip for versatile connections.
Fluke TL175 TwistGuard Test Leads

図1:以上view of Fluke TL175 TwistGuard Test Leads, showing the red and black leads with their respective probe tips and banana plugs.

4. セットアップとインストール

  1. Inspect Leads: Before connecting, visually inspect both test leads for any signs of damage, cuts, or exposed inner insulation. If damage is found, replace the leads immediately.
  2. 機器に接続: Insert the shrouded banana plugs (black for common, red for voltage/current) firmly into the corresponding input jacks of your multimeter or test instrument. Ensure a secure connection.
    Fluke TL175 Test Leads connected to a multimeter

    Figure 2: Fluke TL175 Test Leads properly connected to a digital multimeter.

  3. Adjust TwistGuard Shroud: The TwistGuard feature allows you to adjust the exposed tip length.
    • For CAT II measurements (e.g., wall outlets), twist the probe handle to fully expose the 19mm tip.
    • For CAT III or CAT IV measurements (e.g., circuit breaker panels, main service), twist the probe handle to retract the shroud, exposing only the 4mm tip for increased safety.
      Hand demonstrating the TwistGuard feature on a Fluke TL175 test lead

      Figure 3: A hand twisting the probe handle to adjust the TwistGuard tip shroud.

  4. Attach Lantern Tips (Optional): If your application requires a different connection type, the included 4mm lantern tips can be threaded onto the probe tips.

5. 操作手順

Once properly connected and adjusted, the Fluke TL175 Test Leads function as standard test probes for your electrical measurements. Always refer to your multimeter's instruction manual for specific measurement procedures.

  • 巻tage測定: 適切な巻を選択してくださいtage range on your multimeter. Ensure the TwistGuard shroud is set for the correct safety category. Place the black probe on the common or ground point and the red probe on the point to be measured.
  • 電流測定: For current measurements, ensure the red lead is connected to the correct current input jack on your multimeter (e.g., 10A or mA). The circuit must be broken to insert the meter in series.
  • Resistance/Continuity: Select the resistance or continuity function. The leads can be used to test circuit continuity or component resistance.
Fluke TL175 Test Lead being used to measure in a circuit breaker panel

Figure 4: Using a Fluke TL175 Test Lead in a circuit breaker panel, demonstrating a CAT IV application with the shroud retracted.

Fluke TL175 Test Leads being used to test an electrical outlet

Figure 5: Fluke TL175 Test Leads used to test an electrical outlet, suitable for CAT II applications with tips fully exposed.

6. メンテナンス

  • クリーニング: Clean the test leads with a damp 布と中性洗剤。 研磨剤や溶剤は使用しないでください。
  • 検査: Regularly inspect the leads for any signs of wear or damage, especially the WearGuard insulation. If the inner contrasting color is exposed, the leads are compromised and should be replaced to maintain safety.
  • ストレージ: Store the test leads in a clean, dry environment, away from extreme temperatures and direct sunlight. Avoid sharp bends or kinks in the cables.

7。 トラブルシューティング

  • No Reading or Intermittent Reading:
    • Ensure the banana plugs are fully inserted into the multimeter.
    • Check for visible damage to the lead insulation or connectors.
    • Perform a continuity test on the leads themselves by touching the tips together. If no continuity, the leads may be internally broken and require replacement.
  • 不正確な読み取り:
    • Verify the multimeter is set to the correct function and range.
    • Ensure the test lead tips are making good contact with the circuit points.
    • Check for corrosion or dirt on the probe tips or banana plugs.

8. 仕様

特徴仕様
モデル番号TL175
安全性評価CAT II 1000V, CAT III 1000V, CAT IV 600V, 10A maximum, Pollution Degree 2
Exposed Probe Tip Length19mm to 4mm (0.75" to 0.16") adjustable
Lead Wire MaterialDouble Insulated Silicone
動作温度-20 ~ 55 °C (-4 ~ 131 °F)
高度2000m (6,562')
コンプライアンスEN61010-031
製品寸法10 x 3 x 2インチ
アイテム重量120グラム(4.23オンス)

箱の中身:

  • Fluke TL175 TwistGuard Test Leads (Red and Black)
  • Removable 4mm Lantern Tips

9. 保証とサポート

The Fluke TL175 TwistGuard Test Leads come with a 1-year warranty from the date of purchase, covering defects in materials and workmanship. For warranty claims, technical assistance, or further information, please contact Fluke Corporation customer support or visit the official Fluke webサイト。

メーカー: フルークコーポレーション

発売日: 1年2011月XNUMX日

関連文書 - TL175

前view Fluke 179 デジタルマルチメーター:メンテナンスおよびフィールドサービスガイド
Fluke 179 True-rms デジタルマルチメーターは、電気設備および HVAC メンテナンスの効率化を目的として設計されています。信頼性の高いフィールドサービスのために、その機能、仕様、推奨アクセサリについてご紹介します。
前view Fluke 15B+/17B+/18B+ デジタルマルチメーター ユーザーマニュアル
Fluke 15B+、17B+、18B+デジタルマルチメーターの包括的なユーザーマニュアル。機能、操作、安全性、メンテナンス、仕様を網羅しています。このマニュアルでは、マルチメーターを様々な電気測定に使用するための詳細な手順を説明しています。
前view Fluke 106/107 手のひらサイズデジタルマルチメーター:技術仕様と機能
Fluke 106および107手のひらサイズ・デジタルマルチメーターの詳細な技術仕様、製品特長、および一般情報をご紹介します。電気仕様、精度、機能、付属機器についてもご確認ください。
前view Fluke 107 Handheld CAT III Digital Multimeter - Technical Specifications
Detailed technical specifications, features, and general information for the Fluke 107 handheld CAT III digital multimeter. Includes electrical measurements, safety ratings, and ordering details.
前view Fluke FEV100 電気自動車充電ステーション用アダプターキット: 技術データと仕様
Fluke FEV100 アダプターキットの技術仕様、機能、テスト手順をご覧ください。このキットは、電気自動車充電ステーション(EVSE)を安全かつ効率的にテストするために設計されています。安全性に関する情報、互換性、注文方法などが記載されています。
前view Fluke 110 True-RMS Multimeter: Technical Specifications and Features
Detailed specifications and features of the Fluke 110 compact True-RMS multimeter, designed for precise electrical installation and troubleshooting. Includes accuracy, safety ratings, and included accessories.