導入
This manual provides instructions for the installation, operation, and maintenance of the Intermatic T174 DPST 24 Hour Time Switch. This electromechanical timer is designed for controlling electrical loads over a 24-hour period.
Image: Intermatic T174 DPST 24 Hour Time Switch. This image shows the front view of the timer with its gray metal enclosure and the dial for setting time.
安全情報
WARNING: Risk of electric shock. Installation and servicing must be performed by qualified personnel only. Disconnect power at the circuit breaker or fuse box before installing or servicing the timer.
- 必ず現地の電気規則および規制に従ってください。
- Ensure the power supply matches the timer's voltage rating (208-277V AC).
- Do not exceed the maximum current and horsepower ratings of the timer.
- This device is intended for indoor use in a Type 1 enclosure.
パッケージ内容
The Intermatic T174 Time Switch package typically includes:
- One (1) Intermatic T174 Time Switch Unit
- 取扱説明書
- Two (2) Trippers for setting ON/OFF times
セットアップとインストール
The Intermatic T174 is designed for fixed installation. Proper wiring is crucial for safe and correct operation.
取り付け
- Choose a suitable indoor location for mounting the timer, ensuring it is protected from moisture and extreme temperatures.
- Securely mount the timer's enclosure to a wall or suitable surface using appropriate fasteners.
Wiring (DPST Configuration)
The T174 features a Double Pole, Single Throw (DPST) contact form, meaning it controls two independent circuits or a single 2-pole circuit simultaneously.
- DISCONNECT ALL POWER to the circuit at the main service panel before proceeding.
- タイマーの筐体を開きます。
- Connect the incoming power lines (L1 and L2 for 208-277V AC) to the designated "LINE" terminals on the timer.
- Connect the load wires (to the device being controlled) to the designated "LOAD" terminals. Ensure correct polarity if applicable.
- すべてのワイヤー接続がしっかりと固定されていることを確認します。
- Close the timer's enclosure securely.
- 回路の電源を復旧します。
配線手順が不明な場合は、資格のある電気技師に相談してください。
操作手順
The T174 uses a mechanical dial and trippers to set the ON/OFF schedule.
現在時刻の設定
- Rotate the timer dial clockwise until the current time aligns with the "TIME SET" arrow or indicator on the timer mechanism.
- Ensure AM/PM is correctly observed if the dial has such markings.
オン/オフ時間の設定
The timer comes with two trippers: one "ON" tripper and one "OFF" tripper. Additional trippers can be purchased separately (Extra Trippers 11Z965).
- Locate the "ON" tripper (typically silver or light-colored) and the "OFF" tripper (typically black or dark-colored).
- Snap the "ON" tripper onto the dial at the desired time you want the connected device to turn ON.
- Snap the "OFF" tripper onto the dial at the desired time you want the connected device to turn OFF.
- You can set up to 12 ON/OFF cycles per 24-hour period using additional trippers. The minimum time setting is 1 hour.
手動オーバーライド
The T174 typically includes a manual override switch or lever. This allows you to temporarily turn the connected device ON or OFF without affecting the programmed schedule. Refer to the specific markings on your timer for the manual override function.
Day Skipper Function
The timer features a Day Skipper function, allowing you to prevent operation on specific days of the week. Consult the detailed instruction guide included with your unit for specific setup of this feature.
メンテナンス
The Intermatic T174 Time Switch is designed for reliable, long-term operation with minimal maintenance.
- Periodically inspect the timer for any signs of damage or loose connections.
- Keep the enclosure clean and free from dust and debris.
- Do not attempt to lubricate internal components.
トラブルシューティング
| 問題 | 考えられる原因 | 解決 |
|---|---|---|
| タイマーが作動しません。 | タイマーに電源が供給されていません。 | ブレーカーまたはヒューズを確認してください。配線接続が確実に行われていることを確認してください。 |
| Connected device does not turn ON/OFF at programmed times. | Incorrect tripper placement or current time setting. | Verify tripper positions and ensure the current time is accurately set on the dial. Check manual override switch position. |
| Timer motor is noisy. | 一部の機械式タイマーの通常の動作。 | If noise is excessive or new, contact support. |
| Timer operates but device does not. | Faulty wiring to the load or issue with the connected device. | Verify load wiring. Test the connected device directly to ensure it is functional. |
仕様
| 特徴 | 詳細 |
|---|---|
| モデル番号 | T174 |
| タイプ | 電気機械式タイマー |
| 手術 | 24時間 |
| Number of Poles | 2 |
| お問い合わせフォーム | DPST-NO (Double Pole, Single Throw - Normally Open) |
| 巻tage | 208-277V AC |
| Amp怒る | 40A |
| Contact HP @ 120V | 2馬力 |
| Contact HP @ 240V | 5馬力 |
| Day Skipper | はい |
| エンクロージャタイプ | Steel, Type 1 Indoor Enclosure |
| 仕上げる | グレーエナメル |
| 最小時間設定 | 1時間 |
| 最大時間設定 | 23時間 |
| Maximum ON/OFF Cycles | 12 |
| 寸法(高さ×幅×奥行き) | 7 13/16 in x 5 in x 3 in (Approximate) |
| アイテム重量 | 2.75~2.8ポンド |
| Included Trippers | 2 |
| 欧州連合 | 078275174214 |
| メーカー | インターマティック株式会社 |
保証とサポート
The Intermatic T174 Time Switch comes with a manufacturer's warranty. For specific warranty details, please refer to the documentation included with your product or visit the official Intermatic webサイト。
For technical support, troubleshooting assistance, or to inquire about replacement parts, please contact Intermatic customer service. You can often find support information and additional resources on the Intermatic Store on Amazon または公式の企業 webサイト。