Read and understand all safety warnings and instructions before operating this fluid pump. Failure to follow these instructions may result in property damage or personal injury.

  • Always wear appropriate personal protective equipment, including safety glasses and gloves, when handling automotive fluids.
  • Ensure the work area is well-ventilated to avoid inhaling hazardous fumes.
  • Do not use this pump with corrosive or highly flammable liquids. Refer to the fluid manufacturer's safety data sheet (SDS) for proper handling.
  • 子供や権限のない人員を作業エリアに近づけないでください。
  • Dispose of used fluids and cleaning materials according to local environmental regulations.
  • Check all connections for leaks before and during operation.

2.製品オーバーview

The VEVOR 7.5L Manual Transmission Fluid Pump is designed for efficient and clean transfer of various automotive fluids, including transmission fluid, engine oil, brake fluid, gear lubricants, coolant, and power steering fluid. Its manual piston design ensures precise control and leak-secure operation.

2.1 箱の中身

  • 1 x Transmission Fluid Pump (7.5L Tank)
  • 1 x Outlet Hose with Shut-off Valve (120 cm / 47 in)
  • 1 x Rocker (Pump Handle)
  • 8 x ATF Adapters
  • 1 x Phillipsドライバー
  • オープンエンドレンチ1本
  • 2 x Cross Bolts with Lock Nuts (M6x20)
  • ユーザーマニュアル x 1

2.2 主な特徴

  • 7.5 L Capacity Tank: Large, clear HDPE reservoir allows for monitoring fluid levels and supports multiple applications without frequent refilling.
  • Leak-Secure Operation: Features a brass flow valve and multi-seal internals for a tight internal oil path and steady pressure, minimizing spills.
  • Fast Pumping Power: Long-lever, piston design enhances stroke volume with less effort for quicker fluid transfer.
  • Precise Fit Adapters: Includes 8 metal ATF fill adapters compatible with various vehicle brands like Ford, BMW, VW/Audi, Honda, and Nissan.
  • 耐久性のある構造: HDPE reservoir resists oil and chemicals, while reinforced metal adapters ensure longevity.
VEVOR 7.5L Manual Transmission Fluid Pump with hose and adapters

Image: The VEVOR 7.5L Manual Transmission Fluid Pump, showing the main tank, pump handle, and included accessories.

3. セットアップ手順

Follow these steps to assemble and prepare your fluid pump for use.

  1. ハンドルを取り付けます: Attach the rocker (pump handle) to the top of the pump unit using the provided cross bolts and lock nuts. Ensure it is securely fastened.
  2. Open and Fill: Unscrew the top cap of the 7.5L tank. Carefully pour the desired fluid into the tank. Do not overfill; leave some space for air. Securely close the cap.
  3. Connect Hose and Adapter: Connect the outlet hose to the pump's output port. Select the appropriate ATF adapter for your vehicle's transmission fill port. Connect the adapter to the end of the outlet hose. Ensure all connections are tight to prevent leaks.
  4. Position for Transfer: Place the pump on a stable, level surface. Insert the adapter into the vehicle's transmission fill port.
  5. ポンピングの準備: Ensure the shut-off valve on the outlet hose is in the closed position before starting to pump.
Five steps for setting up and using the VEVOR fluid pump: install handle, fill tank, connect hose and adapter, open valve, and pump.

Image: Visual guide illustrating the five key steps for setting up and preparing the fluid pump for operation.

4. 操作手順

This section details the process for transferring fluids using the VEVOR pump.

  1. 接続を確認します。 Double-check that all hose and adapter connections are secure and leak-free.
  2. Open Shut-off Valve: Once the adapter is securely in the vehicle's fill port, open the shut-off valve on the outlet hose to allow fluid flow.
  3. ポンピングを開始します: Operate the pump handle (rocker) with steady, consistent strokes. The piston design will draw fluid from the tank and push it through the hose into the vehicle's system.
  4. 液面レベルを監視する: Observe the fluid level in the transparent tank and the vehicle's fill indicator (if applicable) to prevent overfilling. The clear tank allows for easy monitoring.
  5. Stop Transfer: Once the desired fluid level is reached, close the shut-off valve on the outlet hose.
  6. アダプタの取り外し: Carefully remove the adapter from the vehicle's fill port. Be prepared for any residual drips.
Mechanic using the VEVOR fluid pump to refill transmission fluid under a car

Image: The VEVOR fluid pump in operation, demonstrating fluid refilling under a vehicle with the long leverage handle and piston pump.

4.1 Adapter Selection

The kit includes 8 different ATF adapters to ensure compatibility with a wide range of vehicle makes and models. Refer to your vehicle's service manual to identify the correct adapter for your specific application.

  • ATF101: フォード
  • ATF102: Universal Interface (BMW, Nissan, Honda, etc.)
  • ATF103: Proprietary Interface (Audi, VW, Skoda)
  • ATF104: Proprietary Interface (Porsche, VW, Audi)
  • ATF105: M10x1 (VW, Mini Cooper, Audi)
  • ATF106: M24x1.5 (VW DSG, Audi)
  • ATF107: M22x1.5 (VW CVT, Audi)
  • ATF109: M12x1.5 (ALTIS 2010, BENZ 722.9)
Close-up of the 8 included ATF adapters with their corresponding vehicle compatibility

Image: A display of the eight different ATF adapters included with the pump, showing their unique designs and compatible vehicle brands.

5. メンテナンス

Proper maintenance ensures the longevity and reliable performance of your fluid pump.

5.1 クリーニング

  • After each use, especially when changing fluid types, clean the tank, hose, and adapters thoroughly.
  • Flush the pump and hose with a suitable cleaning agent or a small amount of the new fluid to remove residues.
  • Wipe down the exterior of the pump and tank with a clean cloth.
  • Ensure all components are dry before storage to prevent corrosion or contamination.
Close-up of the pump's tight-fit connectors, sealed PU hose, and leak-proof brass control valve

Image: Details of the pump's sealed components, including tight-fit connectors, a sealed and durable PU hose, and a leak-proof brass control valve, which contribute to a clean workspace.

5.2 ストレージ

  • Store the pump in a clean, dry place, away from direct sunlight and extreme temperatures.
  • Keep the adapters organized in their case to prevent loss or damage.
  • Ensure the tank is empty and clean before long-term storage.
Images showing the rugged HDPE tank, kink-resistant PU hose, and reinforced metal fittings of the VEVOR fluid pump

Image: Components highlighting the pump's durability, including the rugged HDPE tank, kink-resistant PU hose, and reinforced metal fittings, designed for demanding shop environments.

6。 トラブルシューティング

このセクションでは、操作中に発生する可能性のある一般的な問題について説明します。

問題考えられる原因解決
Fluid not pumping or low pressure
  • 遮断弁が閉まっている
  • 緩い接続
  • システム内の空気漏れ
  • タンクが空
  • Pump mechanism issue
  • 遮断弁を開きます。
  • Tighten all hose and adapter connections.
  • Check for cracks in the hose or tank.
  • Refill the tank with fluid.
  • Inspect the piston and seals for damage.
Fluid leaks from connections
  • 緩い接続
  • 損傷したOリングまたはシール
  • 間違ったアダプタが使用されている
  • すべての接続をしっかりと締めます。
  • 損傷した O リングまたはシールを点検し、交換します。
  • Ensure the correct adapter is used and properly seated.
Difficulty attaching adapter
  • Incorrect adapter selected
  • Debris in port or adapter
  • Verify the correct adapter for your vehicle.
  • Clean the vehicle's fill port and the adapter.

7. 仕様

特徴詳細
商品型番YS-059A
容量7.5 L (1.98 米ガロン)
排出方法Manual Piston Press with Flow Control Valve
主な材質HDPE(高密度ポリエチレン)
製品重量3.1 kg (6.61 ポンド)
製品寸法(長さ x 幅 x 高さ)290 x 520 x 495 mm (11.42 x 20.47 x 19.49 インチ)
アウトレットホースの長さ120 cm (47 インチ)
付属アダプター8 ATF Adapters (1/8"-27, M10x1.0, M24x1.5, M22x1.5, M12x1.5, etc.)
VEVOR fluid pump with a list of its technical specifications

Image: The VEVOR fluid pump displayed alongside its detailed technical specifications, including model number, capacity, and dimensions.

8. 保証情報

保証の詳細については、製品に付属の保証書を参照するか、公式VEVORをご覧ください。 webサイトでご確認ください。保証請求の際は購入証明として領収書を保管してください。

9. サポート

If you have any questions, require technical assistance, or need to report an issue with your VEVOR Transmission Fluid Pump, please contact VEVOR customer support. Contact information can typically be found on the VEVOR official webサイトまたは製品のパッケージ内。

追加のリソースと製品情報については、 AmazonのVEVORストア.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.