導入
The MAXUS Gold Milligram Scale D205 is a high-precision digital scale designed for accurate measurements up to 100g with 0.001g readability. It is suitable for various applications including weighing powders, jewelry, and reloading components. This manual provides detailed instructions for setting up, operating, and maintaining your scale to ensure optimal performance.

Image: The MAXUS Gold Milligram Scale D205, showcasinコンパクトなデザインとデジタルディスプレイが特徴です。
パッケージ内容
パッケージにすべてのアイテムが揃っていることを確認します。
- MAXUS Gold Milligram Scale D205
- 20g Calibration Weight (x2)
- Weighing Pan/Tray
- スクープ
- ピンセット
- USB-Cケーブル
- AAAバッテリー(x2)

Image: All components included with the MAXUS Gold Milligram Scale D205.
設定
1. 電源
The MAXUS D205 scale can be powered by two AAA batteries or via the included USB-C cable.
- バッテリー電源: Open the battery compartment on the underside of the scale and insert two AAA batteries, ensuring correct polarity.
- USB電源: Connect the provided USB-C cable to the scale's USB-C port and plug the other end into a compatible USB power source (e.g., a wall adapter, computer USB port). The scale can operate without batteries when connected via USB.

Image: The scale can be powered by AAA batteries or a USB-C cable.
2.配置
Place the scale on a stable, flat, and level surface. Avoid areas with vibrations, drafts, or extreme temperature changes, as these can affect accuracy. Ensure the clear protective cover is properly positioned to shield the weighing pan from air currents.
操作手順
1. 電源のオン/オフ
「オン/オフ" button to turn the scale on. Press and hold the "オン/オフ" button to turn the scale off. The scale will automatically shut off after a period of inactivity to conserve power.
2.単位変換
「モード" button to cycle through the available weighing units: grams (g), ounces (oz), troy ounces (ozt), pennyweights (dwt), carats (ct), and grains (gn). The selected unit will be displayed on the screen.

Image: The scale's display indicating various weighing units.
3. 風袋機能
The tare function allows you to subtract the weight of a container, so you only measure the net weight of its contents.
- Place the empty container (e.g., weighing pan) on the scale's platform.
- 読み取り値が安定するのを待ちます。
- 「風袋" button. The display will reset to 0.000g.
- 計量したい品物を容器に入れてください。ディスプレイには、品物の正味重量のみが表示されます。

Image: Visual guide for using the Tare function.
4. キャリブレーション
Regular calibration ensures the accuracy of your scale. Use the included 20g calibration weights.
- Turn on the scale and wait for it to stabilize at 0.000g.
- 「モード" button for approximately 6 seconds until the display flashes "20.000".
- Place one 20g calibration weight on the center of the weighing platform. The display will then flash "40.000".
- Place the second 20g calibration weight on the platform alongside the first.
- The display will show "PASS" and then return to normal weighing mode, indicating successful calibration. Remove the weights.

Image: Step-by-step instructions for calibrating the scale.
5. Pieces Counting (PCS) Function
この機能を使用すると、同じ重量の複数のアイテムをカウントできます。
- Turn on the scale and ensure it is in weighing mode.
- として配置ampプラットフォーム上のアイテムの数量(例:25、50、75、または 100 個)
- 「PCS" button until "PCS" appears on the display.
- 「モード" button to select the sample quantity you placed (e.g., "25 PCS").
- 「PCS" button again to confirm. The scale is now calibrated for counting.
- Add more items to the platform, and the display will show the total count.
- To exit counting mode, press the "PCS" ボタン。
メンテナンス
- クリーニング: スケールを柔らかい布で拭きます。amp 布で拭いてください。研磨剤入りの洗剤を使用したり、スケールを水に浸したりしないでください。
- ストレージ: Store the scale in a clean, dry environment. Keep the protective cover closed when not in use to prevent dust and debris from affecting the weighing mechanism.
- バッテリー交換: If using batteries, replace them when the low battery indicator appears on the display.
- 取り扱いにはご注意ください: Avoid dropping the scale or subjecting it to sudden shocks, as this can damage the precision sensors.
トラブルシューティング
| 問題 | 考えられる原因 | 解決 |
|---|---|---|
| スケールがオンになりません。 | 電池残量が少ないか切れています。USB 電源がありません。 | Replace batteries or connect to a stable USB power source. |
| 不正確な測定値。 | Not calibrated; unstable surface; drafts; overload. | Perform calibration; place on a stable, level surface; avoid drafts; ensure weight is within capacity. |
| "O_Ld" or "EEEE" displayed. | オーバーロード。 | 余分な重量はすぐに取り除いてください。100gを超えないようにしてください。 |
| Display is unstable or fluctuates. | Vibrations; air currents; electromagnetic interference. | Move scale to a more stable location; close protective cover; keep away from electronic devices. |
仕様
| 特徴 | 詳細 |
|---|---|
| 容量 | 100グラム |
| 読みやすさ | 0.001グラム |
| 計量単位 | g、oz、ozt、dwt、ct、gn |
| 画面 | バックライト付きLCD |
| 機能 | Tare, PCS (Counting), Auto Shut Off |
| 力 | 2 x AAA Batteries (included) or USB-C (cable included) |
| 材料 | アクリロニトリルブタジエンスチレン(ABS) |
| アイテム重量 | 171グラム |
| 寸法(約) | 4.8" (L) x 2.7" (W) x 1.7" (H) (based on image 61OehI5dFvL) |

Image: Approximate dimensions of the scale.
アプリケーション
The MAXUS Gold Milligram Scale D205 is versatile and can be used for various precision weighing tasks:
- Jewelry and precious metals
- Powders and fine ingredients
- Reloading components
- Laboratory use
- Hobby and craft projects

画像: Examples of items that can be weighed with the scale.
カスタマーサポート
For further assistance or inquiries, please contact MAXUS customer support. Refer to the product packaging or the official MAXUS web連絡先の詳細についてはサイト。