Garosa DDS529MR

Garosa DDS529MR Single Phase Electric Energy Meter User Manual

Model: DDS529MR

導入

This manual provides detailed instructions for the installation, operation, and maintenance of the Garosa DDS529MR Single Phase Electric Energy Meter. This device is designed for measuring active energy in single-phase AC power systems. It features an LCD digital display with backlight, RS485 communication, and displays power, voltage, current, power factor, frequency, and rotation.

安全情報

  • 設置とメンテナンスは資格のある担当者のみが行う必要があります。
  • 設置や配線作業を行う前に、必ず電源を切ってください。
  • 過度の湿気、ほこり、腐食性ガスのある環境ではメーターを操作しないでください。
  • Verify all connections are secure and correct according to the wiring diagram to prevent damage or electric shock.
  • このメーターは屋内使用のみを目的として設計されています。

製品終了view

The DDS529MR energy meter is a compact device for accurate energy measurement. Key features include a clear LCD display, RS485 communication for data integration, and a standard DIN rail mounting for easy installation.

Garosa DDS529MR Energy Meter Labeled Components

図1: フロント view of the DDS529MR energy meter with labeled components.

  • A: 製品名
  • B: Electronic Display (LCD)
  • C: Battery Display (if applicable)
  • D: モデル番号
  • E: IEC Certificate Mark
  • F: Product Parameters (e.g., 230V, 5(80)A, 50Hz, 1000imp/kWh)
  • G: 電源インジケータLED
  • H: Pulse Indicator LED
  • I: Address / Baud Rate / Parity Modification, Switch Voltage/Current/Charge Display (via TURN/SET buttons)
  • J: ブランド名
  • K: Setting Button (SET)
Garosa DDS529MR Energy Meter LCD Display

図2: 閉じる view of the LCD digital display with backlight.

仕様

パラメータ価値
モデルDDS529MR
精度レベル1
表示タイプバックライト付きLCD
エネルギー範囲の測定0.0〜99999.0 kWh
電源AC
出力巻tage230V 交流
定格巻tage230V 交流
フェーズ番号単相
パルス周波数1000インプレッション/ kWh
定格電流5A
最大電流80A
寸法約100 x 35 x 65mm(3.9 x 1.4 x 2.6インチ)
インストール35mmDINレール
コミュニケーションRS485(MODBUS-RTU)
アイテム重量210グラム
Garosa DDS529MR Energy Meter Dimensions

図3: Dimensions of the DDS529MR energy meter.

セットアップとインストール

取り付け

The DDS529MR energy meter is designed for standard 35mm DIN rail installation. Ensure the DIN rail is securely mounted in a suitable enclosure or panel.

  1. Align the meter's DIN rail clip with the DIN rail.
  2. カチッと音がするまでメーターをレールにしっかりと押し付けます。
  3. Verify the meter is securely fastened and does not wobble.
Garosa DDS529MR Energy Meter DIN Rail Clip

図4: 後方 view showing the DIN rail mounting mechanism.

配線図

Refer to the following diagram for correct wiring connections. Ensure all power is disconnected before wiring.

Garosa DDS529MR Energy Meter Wiring Diagram

図5: Wiring diagram for the DDS529MR energy meter, including power and RS485 connections.

  • ターミナル1と2: Live (L) and Neutral (N) input for power supply.
  • ターミナル3と4: Live (L) and Neutral (N) output for load.
  • ターミナル21と20: Pulse output (SO+ and SO-).
  • Terminals A & B (RS485): Data communication lines for RS485 (MODBUS-RTU).

Connect the main power supply to the input terminals (L and N). Connect the load to the output terminals (L and N). For RS485 communication, connect the A and B terminals to your RS485 network.

操作手順

電源オン

Once correctly wired and mounted, switch on the main power supply. The LCD display will illuminate, and the power indicator LED (G in Figure 1) will light up.

ナビゲーションを表示

The meter features a rotating display of various parameters. Use the 順番 button to manually cycle through the displayed values:

  • 総有効エネルギー(kWh)
  • リアルタイムVoltage(V)
  • Real-time Current (A)
  • Real-time Active Power (W)
  • 力率(PF)
  • 周波数 (Hz)

The display will automatically rotate through these parameters at regular intervals. Pressing the 順番 button allows for manual advancement to the next parameter.

RS485通信

The DDS529MR supports RS485 communication using the MODBUS-RTU protocol. This allows for remote reading of energy data and other parameters. Refer to the MODBUS protocol documentation for detailed register addresses and communication settings.

セット button (K in Figure 1) is typically used for configuring communication parameters such as baud rate and address, or for resetting certain values. Consult the full technical datasheet for specific programming instructions if available.

メンテナンス

  • クリーニング: メーターの外装を清掃する際は、柔らかく乾いた布をご使用ください。研磨剤入りの洗剤や溶剤は使用しないでください。
  • 検査: Periodically inspect the wiring connections for tightness and signs of wear or damage.
  • 環境: メーターの寿命を延ばすには、動作環境が指定された温度と湿度の範囲内に保たれていることを確認してください。
  • ユーザーが修理可能な部品はありません: The meter contains no user-serviceable parts. Do not attempt to open or repair the device.

トラブルシューティング

問題考えられる原因解決
表示が空白No power supply; incorrect wiring; internal fault.Check power connections and ensure power is on. Verify wiring according to the diagram. If problem persists, contact support.
誤った測定値Incorrect wiring; meter not calibrated; external interference.Double-check all wiring. Ensure the meter is installed correctly for single-phase measurement. If readings are consistently off, contact support.
RS485 通信障害Incorrect wiring of A/B lines; wrong baud rate/address; software configuration issue.Verify RS485 wiring. Check baud rate, parity, and address settings on both the meter and the communication device. Consult MODBUS protocol documentation.
Pulse indicator not flashingNo load connected; very low power consumption; internal fault.Ensure a load is connected and drawing power. The pulse rate is 1000 imp/kWh, so for very low loads, flashes may be infrequent.

保証とサポート

Garosa products are manufactured to high-quality standards. For warranty information, please refer to the specific terms provided at the time of purchase or contact your vendor. For technical support or inquiries, please reach out to the Garosa customer service department or your local distributor.

© 2024 Garosa. All rights reserved.