RCYAGO PH-W2839

RCYAGO WiFi Tuya pH ORP Temperature Controller Monitor User Manual

Model: PH-W2839 | Brand: RCYAGO

1.製品オーバーview

The RCYAGO PH-W2839 is a versatile 3-in-1 monitor designed for comprehensive water quality analysis. It accurately measures pH, Oxidation-Reduction Potential (ORP), and temperature, providing real-time data and control capabilities. Equipped with WiFi connectivity, it integrates with the Tuya app for remote monitoring, data logging, and alarm settings, making it ideal for aquariums, aquaculture, and various water management applications.

RCYAGO WiFi Tuya pH ORP Temperature Controller Monitor with probes and power strip

図1: The RCYAGO WiFi Tuya pH ORP Temperature Controller Monitor, showing the main unit, connected pH, ORP, and temperature probes, and the dual-socket power control strip.

Banner highlighting 3-in-1 pH Monitor features: Accurate Measurement, Wide Applications, Automatic Temperature Compensation

図2: Key features of the 3-in-1 monitor, including accurate measurement, wide application range, and automatic temperature compensation.

2. パッケージ内容

パッケージにすべてのアイテムが含まれていることを確認してください。

  • 1 x WiFi Online pH ORP Temperature Controller Unit
  • 1 x pH Electrode
  • 1 x ORP Electrode
  • 1 x温度プローブ
  • 1 x Dual-Socket Power Control Strip
  • Calibration Powders (pH 4.01, pH 6.86/7.0, pH 9.18/10.01, ORP 256mV)
  • 電源アダプター x 1
  • ユーザーマニュアル
閉じる view of the ORP electrode, pH electrode, temperature electrode, and power plug

図3: 詳細 view of the high-precision ORP electrode, pH electrode, temperature electrode, and the power plug included with the device.

3. セットアップとインストール

Follow these steps to set up your pH ORP Temperature Controller:

  1. コントローラの取り付け: Choose a suitable location near your water body (aquarium, tank, etc.) and mount the main controller unit securely. Ensure it is protected from direct splashes.
  2. Connecting Electrodes: Carefully connect the pH electrode, ORP electrode, and temperature probe to their respective BNC connectors and jack on the main controller unit. Ensure connections are firm.
  3. Connecting Power Control Strip: Plug the dual-socket power control strip into the designated output port on the main controller. This strip will be used to connect external devices (e.g., CO2 solenoid valve, heater) that you wish to control based on pH or ORP levels.
  4. プローブの配置: Submerge the pH electrode, ORP electrode, and temperature probe into the water you intend to monitor. Ensure the sensing parts of the electrodes are fully immersed and positioned to get accurate readings, away from strong currents or air bubbles.
  5. 電源接続: Plug the main controller's power adapter into a standard electrical outlet. The device will power on.
  6. WiFi Connection (Tuya App):
    • モバイル デバイスのアプリ ストア (iOS または Android) から「Tuya Smart」または「Smart Life」アプリをダウンロードします。
    • アカウントに登録またはログインします。
    • Follow the in-app instructions to add a new device. The controller should enter pairing mode automatically or by pressing the WiFi button.
    • Connect the device to your 2.4GHz WiFi network.
Diagram illustrating the connection of the pH ORP Temperature Controller to a CO2 bottle, solenoid valve, power outlet, and an aquarium with probes immersed.

図4: A typical setup diagram showing the controller connected to a CO2 system and probes immersed in an aquarium.

The WiFi pH ORP Temperature Controller connected to a small aquarium, displaying real-time data and showing a mobile phone screen with the Tuya app interface.

図5: The controller in operation, demonstrating WiFi connectivity and real-time data transfer to a mobile application.

4. キャリブレーション

Regular calibration ensures the accuracy of your pH and ORP readings. It is recommended to calibrate the device upon initial setup and periodically thereafter.

4.1. pH キャリブレーション

The device supports 3-point pH calibration (pH 7.0, pH 4.01, pH 10.01).

  1. Prepare fresh pH buffer solutions (pH 7.0, pH 4.01, pH 10.01).
  2. Rinse the pH electrode with distilled water and gently blot dry.
  3. Immerse the pH electrode into the pH 7.0 buffer solution.
  4. Press the 'CAL' button under the pH display on the controller. The device will automatically recognize the buffer and calibrate. Wait for the reading to stabilize.
  5. 電極を再度すすいでください。
  6. Repeat the process for pH 4.01 and pH 10.01 buffer solutions. Ensure to calibrate in ascending or descending order as per device prompts.

4.2. ORP Calibration

The device supports ORP calibration using a 256mV standard solution.

  1. Prepare a fresh 256mV ORP standard solution.
  2. Rinse the ORP electrode with distilled water and gently blot dry.
  3. Immerse the ORP electrode into the 256mV standard solution.
  4. Press the 'CAL' button under the ORP display on the controller. The device will automatically recognize the standard and calibrate. Wait for the reading to stabilize.
Banner showing 3-point pH calibration (pH 4.01, pH 6.86, pH 9.18) and ORP calibration (256mV) with buffer solutions.

図6: Visual guide for the 3-point pH calibration and ORP calibration process using standard buffer solutions.

5. 操作手順

5.1. リアルタイム監視

Once powered on and probes are immersed, the controller's LCD screen will display real-time pH, ORP, and temperature readings. The WiFi indicator will show connection status.

5.2. Tuya App Functionality

The Tuya app provides advanced monitoring and control features:

  • リアルタイムデータ: View current pH, ORP, and temperature readings remotely.
  • 歴史的なデータ: Access daily, weekly, and monthly data logs for trend analysis.
  • アラーム設定: Set high and low alarm thresholds for pH and ORP. Receive notifications on your mobile device if values exceed or fall below these thresholds.
  • スマートなシーン作成: Create automated rules (smart scenes) within the Tuya app to control connected devices via the power strip. For example, turn on a CO2 solenoid when pH rises above a certain level.
The WiFi pH ORP Temperature Controller displaying readings, alongside a mobile phone showing the Tuya app interface with ORP warning settings and historical data graphs.

図7: The controller's display and the Tuya app interface, demonstrating real-time monitoring and alarm settings.

Banner showing APP ALARM SETTINGS with screenshots of the Tuya app for setting high/low alarm values and creating smart scenes for security and alarm methods.

図8: Illustration of the app's alarm setting capabilities, allowing users to define thresholds and trigger actions.

Banner showing real-time data transmission with options to view daily, weekly, and monthly data, set against a swimming pool background.

図9: The device provides real-time data transmission, allowing users to view historical data trends over various periods.

6. メンテナンス

Proper maintenance extends the lifespan and ensures the accuracy of your electrodes and controller.

  • 電極洗浄: Regularly clean the pH and ORP electrodes with distilled water to remove any buildup or contaminants. For stubborn deposits, use a mild cleaning solution specifically designed for electrodes, following the manufacturer's instructions.
  • 電極の保管: When not in use, store the pH and ORP electrodes in their protective caps filled with a suitable storage solution (e.g., KCL solution or pH 4 buffer). Never store electrodes dry.
  • 再校正: Calibrate the pH and ORP electrodes regularly, especially if you notice inconsistent readings or after cleaning. The frequency depends on usage and water conditions.
  • コントローラーユニット: Keep the main controller unit clean and dry. Avoid exposing it to extreme temperatures or direct sunlight.

7。 トラブルシューティング

デバイスで問題が発生した場合は、次の一般的な問題と解決策を参照してください。

問題考えられる原因解決
Inaccurate pH/ORP readingsElectrodes are dirty or aged; improper calibration; air bubbles on electrode.Clean electrodes thoroughly; recalibrate the device; gently tap electrodes to dislodge bubbles. Replace electrodes if they are old or damaged.
WiFi 接続の失敗Incorrect WiFi password; device too far from router; 5GHz WiFi network used; router issues.Ensure correct 2.4GHz WiFi password; move device closer to router; verify router is broadcasting 2.4GHz; restart router and device.
Relay output not triggeringIncorrect alarm settings in Tuya app; device not connected to power strip; external device malfunction.Check and adjust pH/ORP alarm thresholds and smart scene rules in the app; ensure the external device is properly plugged into the control strip and functioning independently.
Temperature reading incorrectTemperature probe not fully immersed or damaged.Ensure the temperature probe is fully submerged; inspect the probe for physical damage.

8. 仕様

Detailed technical specifications for the RCYAGO PH-W2839 monitor:

Banner displaying product specifications including range, resolution, and accuracy for pH, ORP, and Temperature.

図10: 以上view of the device's measurement ranges, resolutions, and accuracy.

パラメータ範囲解決正確さ
pH0.00pH - 14.00pH0.01pH±0.1pH
酸化還元電位-2000mV - +2000mV1mV±5mV
温度0°C - 50°C (32°F - 122°F)1.0°C (0.2°F)±1.0℃
  • 電源: AC 110-240V, 50/60Hz (Specific adapter details may vary)
  • WiFi標準: 2.4GHz 802.11b/g/n
  • 寸法: Approximately 11.1 x 8.11 x 2.99 inches (Controller unit)
  • 重さ: 約2.34ポンド

9. アプリケーション

The RCYAGO WiFi Tuya pH ORP Temperature Controller Monitor is suitable for a wide range of water quality monitoring applications, including but not limited to:

  • Aquariums (Freshwater and Seawater)
  • Aquaculture and Fish Tanks
  • Hydroponics and Plant Cultivation
  • スイミングプールとスパ
  • Domestic Water Quality Testing
  • Laboratory Research and Testing
Collage of images showing the WiFi pH ORP Temperature Controller used in various applications: domestic water, aquarium, fish tank, aquaculture, swimming pool, and laboratory.

図11: The versatility of the monitor across different water quality monitoring scenarios.

An image of a vibrant coral reef aquarium with various fish.
水族館
空中写真 view of an aquaculture farm with multiple circular fish pens in a large body of water.
養殖業
An outdoor swimming pool with lounge chairs and umbrellas.
プール
Two scientists in lab coats working with glassware and equipment in a laboratory setting.
研究所

10. 保証とサポート

This product comes with a standard manufacturer's warranty. For specific warranty terms, duration, and to register your product, please refer to the warranty card included in your package or visit the official RCYAGO webサイト。

For technical support, troubleshooting assistance, or any inquiries regarding your RCYAGO WiFi Tuya pH ORP Temperature Controller Monitor, please contact RCYAGO customer service through the contact information provided on their official webサイトまたは製品ドキュメントに記載されています。

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.