1. はじめに

This manual provides detailed instructions for the safe and effective use of your BTMETER BT-5800G Ammonia Gas Detector and BT-981D Industrial Thermometer. Please read this manual thoroughly before operation and retain it for future reference.

The BTMETER BT-5800G Ammonia Gas Detector is designed to monitor ammonia (NH3) concentration in real-time. It is suitable for various applications including poultry farms, horse stables, and livestock environments to help manage air quality.

The BTMETER BT-981D Industrial Infrared Laser Thermometer is an industrial device for measuring surface temperatures. It is not intended for measuring human or animal body temperature.

2. 箱の中身

  • 1x BTMETER 5800G Ammonia Gas Detector
  • 1x BTMETER 981D Digital Infrared Laser Thermometer
  • 1x User Manual (for 5800G)
  • 1x User Manual (for 981D)
  • Charging Cable (for 5800G)
  • Carrying Pouch (for 5800G)
  • Battery (for 981D)
Contents of the BTMETER combo package, including the ammonia gas detector, infrared thermometer, manuals, charging cable, and carrying pouch.

図2.1: パッケージ内容

3.製品オーバーview

3.1 BTMETER BT-5800G Ammonia Gas Detector

The BT-5800G is a handheld device designed for accurate ammonia gas detection. It features a large digital display showing NH3 concentration in parts per million (ppm), ambient temperature, and humidity. The device includes an audible alarm for high ammonia levels and a tripod mountable port for continuous monitoring.

フロント view of the BTMETER BT-5800G Ammonia Gas Detector showing its display and control buttons, along with a table of technical parameters.

Figure 3.1: BT-5800G Ammonia Gas Detector with Technical Parameters

底 view of the BTMETER BT-5800G Ammonia Gas Detector highlighting the 1/4 inch tripod mount for stable, continuous monitoring.

Figure 3.2: BT-5800G Tripod Mount

3.2 BTMETER BT-981D Industrial Thermometer

The BT-981D is a non-contact infrared thermometer for industrial surface temperature measurements. It offers a wide temperature range and a 12:1 distance-to-spot ratio for accurate readings from a safe distance. The device features adjustable emissivity and a clear digital display.

側 view of the BTMETER BT-981D Industrial Thermometer showing its laser targeting and display, with icons indicating 0.95 emissivity, ±2-3% accuracy, and 12:1 distance to spot ratio.

Figure 3.3: BT-981D Industrial Thermometer Features

Diagram illustrating the 12:1 distance to spot ratio of the BTMETER BT-981D Industrial Thermometer, showing how measurement area increases with distance.

Figure 3.4: BT-981D Distance to Spot Ratio

4. セットアップ

4.1 BT-5800G Ammonia Gas Detector

充電: The BT-5800G uses a Nickel metal hydride battery. Connect the device to a 5V DC power source using the provided USB charging cable. A red light indicates charging, and a green light indicates a full charge.

Image showing the USB charging interface of the BTMETER BT-5800G Ammonia Gas Detector, with indicators for charging status and examples of charging methods (car, laptop, power bank).

Figure 4.1: BT-5800G USB Charging

4.2 BT-981D Industrial Thermometer

バッテリーの取り付け: Open the battery compartment and insert the included battery, ensuring correct polarity. Close the compartment securely.

5. 操作

5.1 BT-5800G Ammonia Gas Detector

  1. 電源オン/オフ: Press and hold the power button (usually the center button with a power symbol) to turn the device on or off.
  2. 測定: Once powered on, the device will automatically begin detecting ammonia (NH3) concentration, ambient temperature, and humidity. Readings are displayed on the screen.
  3. 単位切り替え(°C/°F): Press the °C/°F button to switch between Celsius and Fahrenheit temperature units.
  4. アラーム設定: Press the 'ALARM' button to access or adjust alarm thresholds. Refer to the device's specific menu for detailed alarm configuration.
  5. モードボタン: Use the 'MODE' button to cycle through different display modes or settings as available.

Video 5.1: Demonstration of the BTMETER BT-5800G Ammonia Gas Detector's display and button functions, including switching temperature units and view読み物。

5.2 BT-981D Industrial Thermometer

  1. 電源オン/オフ: Press the trigger to turn the device on. It will automatically power off after a period of inactivity.
  2. 測定: Aim the thermometer at the target surface and press the trigger. The temperature reading will appear on the display. Ensure the target spot is within the device's distance-to-spot ratio for accurate measurement.
  3. 単位切り替え(°C/°F): Use the dedicated button on the device to switch between Celsius and Fahrenheit.
  4. 放射率調整: If applicable, adjust the emissivity setting to match the material being measured for improved accuracy. Refer to the BT-981D's specific manual for details on emissivity settings.

6. メンテナンス

6.1 クリーニング

  • デバイスの表面を柔らかくて乾いた布で拭いてください。amp 布で拭いてください。研磨剤や溶剤は使用しないでください。
  • Keep the sensor area of the BT-5800G and the lens of the BT-981D clean and free from dust or debris.

6.2 ストレージ

  • デバイスは直射日光や極端な温度を避け、涼しく乾燥した場所に保管してください。
  • If storing for extended periods, remove batteries from the BT-981D.

6.3 Sensor Lifespan (BT-5800G)

The electrochemical principle sensor in the BT-5800G has an expected lifespan of approximately two years. Regular calibration may be required to maintain accuracy over time.

7。 トラブルシューティング

問題考えられる原因解決
デバイスの電源が入らないLow battery (BT-5800G), dead battery (BT-981D), incorrect battery installationCharge BT-5800G, replace battery in BT-981D, check battery polarity.
不正確な測定値Sensor/lens obstruction, environmental interference, incorrect emissivity (BT-981D)Clean sensor/lens, ensure stable environment, adjust emissivity for BT-981D.
アラームが作動しないAlarm threshold set too high, alarm disabledAdjust alarm threshold to a lower value, ensure alarm is enabled in settings.
ディスプレイが機能しないバッテリー残量が少ない、デバイスが故障しているCharge/replace battery. If issue persists, contact customer support.

8. 仕様

8.1 BTMETER BT-5800G Ammonia Gas Detector

  • 検知ガス: アンモニア(NH3)
  • 測定範囲: 0-100 ppmの
  • Measuring Resolution: 0.1ppm
  • 再現性: <±1%
  • 基本的なエラー: < ± 5% (F.S)
  • 応答時間: 60秒未満
  • 回復時間: 60秒未満
  • Principle of Sensor: Electrochemical, lifespan approx. 2 years
  • バッテリー: Nickel metal hydride battery
  • 画面: Large screen liquid crystal display
  • アラーム: Acoustic optical double alarm, adjustable threshold, alarm sound > 80dB
  • 動作温度: -10 °C ~ 50 °C (14 °F ~ 122 °F)
  • 動作湿度: 0-95% RH (Non-Gel)
  • 製品寸法: 奥行き11インチ x 幅2.4インチ x 高さ6.3インチ
  • 商品の重量: 0.66 ポンド

8.2 BTMETER BT-981D Industrial Thermometer

  • 測定範囲: -50 °C ~ 550 °C (-58 °F ~ 1022 °F)
  • 正確さ: ±3% for -50 °C to 0 °C; ±2% for 0 °C to 100 °C; ±3% for ≥100 °C
  • スポットに対する距離の比率: 12:1
  • 放射率: 0.95 (fixed or adjustable, refer to specific manual)
  • 電源: 電池駆動

9. 保証とサポート

BTMETER products are manufactured to high-quality standards. For warranty information, technical support, or service inquiries, please refer to the contact information provided with your product packaging or visit the official BTMETER webサイトでご確認ください。保証請求のために購入証明書を保管してください。