導入

This manual provides essential information for the safe and efficient operation of your Tektronix MSO22 2-BW-100 Mixed Signal Oscilloscope. This instrument is designed for precise measurement and analysis of electronic signals, featuring a 100 MHz bandwidth and 2 analog channels.

主な機能は次のとおりです。

  • Analog input channels: 2 inputs
  • 帯域幅:100 MHz
  • Sample rate: 2.5 GS/s Half channels; 1.25 GS/s All channels
  • Record length: 10 Mpoints per channel
  • Vertical resolution: 8 bits ADC; Up to 16 bits in high-resolution mode

セットアップと接続

Before operating the oscilloscope, ensure it is placed on a stable, level surface with adequate ventilation. Connect the power cord to the instrument and a grounded AC outlet.

フロント view of the Tektronix MSO22 2-BW-100 Mixed Signal Oscilloscope

Figure 1: Front panel of the Tektronix MSO22 2-BW-100 Oscilloscope, showing the display, control knobs, buttons, and input connectors (Inputs 1, 2, Aux In, AFG/Aux Out).

入力接続

  • Analog Inputs (1, 2): Connect your probes to these BNC connectors for signal acquisition.
  • 補助入力: Auxiliary input for external trigger or other signals.
  • AFG/Aux Out: Output for the Arbitrary Function Generator or auxiliary signals.

電源オン

Press the power button located on the front panel to turn on the instrument. Allow a few moments for the system to boot up.

操作手順

This section outlines the basic steps for operating the oscilloscope to capture and analyze waveforms.

Basic Waveform Capture

  1. プローブを接続: Attach a compensated probe to one of the analog input channels (e.g., Input 1).
  2. 回路に接続: プローブの先端を回路のテスト ポイントに接続し、アース クリップを回路のアースに接続します。
  3. 自動設定: を押す Auto-Set button (if available, common on oscilloscopes) to automatically adjust vertical and horizontal settings for a stable display.
  4. 垂直スケールを調整: 使用 垂直スケール knob to adjust the volts per division, controlling the amplitude of the waveform on the screen.
  5. 水平スケールを調整: 使用 水平スケール knob to adjust the seconds per division, controlling the time base of the waveform.
  6. トリガーを調整: 使用 トリガーレベル ボリュームを設定するノブtage level at which the oscilloscope captures the waveform, ensuring a stable display.

測定機能

The MSO22 2-BW-100 offers various automated measurement functions. Access these through the on-screen menu system. Common measurements include Peak-to-Peak Voltage, Frequency, Period, and Rise/Fall Time.

メンテナンス

適切なメンテナンスを行うことで、オシロスコープの寿命と精度が確保されます。

クリーニング

  • 外側の表面を柔らかい布で拭きます。amp 布で拭いてください。研磨剤や溶剤は使用しないでください。
  • 機器内に液体が入らないようにしてください。
  • Clean the display screen with a soft, lint-free cloth specifically designed for electronic displays.

較正

For optimal performance, periodic calibration by qualified service personnel is recommended. Refer to the official Tektronix service manual for calibration procedures and intervals.

トラブルシューティング

このセクションでは、発生する可能性のある一般的な問題に対する解決策を示します。

  • 表示なし:
    • Ensure the power cord is securely connected and the instrument is powered on.
    • Check the brightness and contrast settings of the display.
  • 不安定な波形:
    • Adjust the trigger level and trigger source settings.
    • Verify the probe compensation is correct.
    • Check for proper grounding of the probe and the circuit under test.
  • 信号が検出されません:
    • Ensure the probe is correctly connected to the input channel and the circuit.
    • Check the input coupling (AC/DC/GND) and vertical scale settings.
    • Verify the signal source is active.

問題が解決しない場合は、Tektronix カスタマー サポートにお問い合わせください。

仕様

Detailed technical specifications for the Tektronix MSO22 2-BW-100 Mixed Signal Oscilloscope.

特徴仕様
モデル番号MSO22 2-BW-100
アナログ入力チャンネル2入力
帯域幅100 MHz
Sample Rate (Half Channels)2.5GS/秒
Sample Rate (All Channels)1.25GS/秒
レコード長10 Mpoints per channel
分解能8 bits ADC; Up to 16 bits in high-resolution mode
メーカーテクトロニクス
初回利用可能日17年2022月XNUMX日

保証とサポート

Tektronix products are designed for reliability and performance. For information regarding product warranty, please refer to the warranty statement included with your purchase or visit the official Tektronix webサイト。

For technical support, service, or additional documentation, please contact Tektronix customer service or visit their official support portal. Ensure you have your product model number (MSO22 2-BW-100) and serial number ready when contacting support.

オンラインリソース: www.tek.com

© 2024 Tektronix. 無断複写・転載を禁じます。

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.