1. はじめにview
The Kidde Hardwired Smoke Detector, model i12010S, is designed to provide early warning of fire. This device utilizes ionization sensor technology, which is effective at detecting invisible fire particles often associated with fast-flaming fires. It operates on a 120-volt AC power source and includes a sealed 10-year lithium battery backup, ensuring continuous protection even during power outages. When smoke is detected, an 85-decibel alarm will sound, accompanied by visual indicators. This manual provides essential information for proper installation, operation, and maintenance to ensure optimal performance and safety.

Image 1.1: Key features of the Kidde i12010S Smoke Detector, including 10-year sealed battery, ionization sensor, Smart Hush, 120V AC wiring, end-of-life hush, and LED lights.
2. 重要な安全情報
Read all instructions before installation and operation. Failure to follow these instructions may result in property damage, injury, or death. This smoke alarm is designed for residential use only. It is not intended for use in non-residential buildings or for special applications. Do not paint the alarm. Paint can clog the openings and interfere with the sensor's ability to detect smoke.
2.1 配置ガイドライン
For optimal protection, install smoke detectors on every level of your home, inside each bedroom, and outside each sleeping area. Ensure alarms are not placed within 6 feet of heating or cooking appliances, or in areas with high humidity like bathrooms, as this can lead to nuisance alarms. Refer to local codes and NFPA 72 for specific requirements.

Image 2.1: Recommended placement guide for smoke alarms, carbon monoxide alarms, and fire extinguishers within a typical home layout.
2.2 警告
- 温度と湿度: Constant exposure to high or low temperatures or high humidity may reduce battery life. This unit is designed for indoor use only.
- Radioactive Material: This device contains a small amount of radioactive material. Do not attempt to open or tampユニットと一緒に。
- 人生の終わり: Failure to turn off the alarm as instructed prior to disposal may create potential for lithium battery related fire or hazard.
3. セットアップとインストール
The Kidde i12010S smoke detector is hardwired and requires a 120V AC power supply. It is designed for easy installation, especially when replacing older hardwired units. Always ensure power is turned off at the circuit breaker before beginning installation.
3.1配線手順
Connect the smoke detector to a continuous 120V AC, 60Hz household electrical circuit. Use the provided wiring harness. The black wire is for hot (L), the white wire for neutral (N), and the red wire for interconnect (if applicable). Ensure all connections are secure and comply with local electrical codes.

Image 3.1: The Kidde i12010S smoke detector with its hardwired connection wires (black, white, red) for electrical installation.
3.2 Battery Activation and Mounting
The unit features a sealed 10-year lithium battery that activates upon installation. Once the mounting plate is secured and the unit is twisted onto the plate, a tab is permanently moved, initiating the battery backup. Ensure the 'ON' switch is engaged. Mount the detector firmly to the ceiling or wall according to the placement guidelines.

Image 3.2: The back of the Kidde i12010S smoke detector, detailing wiring connections, important warnings, and a quick reference guide for alarm signals.
3.3 Interconnection Capability
This smoke detector can be interconnected with up to 24 compatible Kidde smoke, heat, or CO alarms. When one interconnected alarm senses smoke, all connected alarms will sound, providing enhanced warning throughout your home. The red interconnect wire facilitates this feature.
4. 操作
Once installed and powered, the smoke detector continuously monitors for smoke. Familiarize yourself with its indicators and functions.
4.1 Test/Hush Button
The large central button on the front of the alarm serves two functions:
- テスト: Press and hold the button to test the alarm's electronic circuitry, horn, and battery. The alarm will sound if functioning correctly. Test weekly.
- ハッシュ: In case of a nuisance alarm (e.g., from cooking smoke or shower steam), press the button to temporarily silence the alarm for approximately 8-10 minutes. The alarm will automatically reset after this period.

画像4.1:正面 view of the Kidde i12010S smoke detector, highlighting the central push-to-test/hush button and the green/red LED indicators.
4.2 LED Indicators and Alarm Signals
The unit has a green LED for power/standby and a red LED for alarm/trouble conditions.
| 信号 | 表示 |
|---|---|
| Three long "beeps" | Indication of fire hazard. |
| One "chirp" every 60 seconds | 低バッテリーの兆候。 |
| One "chirp" every 30 seconds prior to "replace by" date | Indication of a dirty sensor or malfunction. |
| Two "chirps" every 30 seconds after "replace by" date | Indication that it is time to replace the alarm. REPLACE IMMEDIATELY! ALARM WILL NOT DETECT SMOKE IN THIS CONDITION. |
| 常時緑色 LED | Indication that AC power is connected. |
| Green LED blinks 1 time every second | Indication that unit has initiated an alarm. |
| Green LED blinks 1 time every 10 seconds | Indication that unit is in HUSH mode. |
| Green LED blinks 1 time every 48 seconds | Indication that unit is powered by battery only. |
| Green LED blinks 1 time every 16 seconds | Indication of a previous alarm. |
5. メンテナンス
Regular maintenance ensures your smoke detector remains operational and effective.
5.1 週次テスト
Test your smoke alarm weekly by pressing and holding the Test/Hush button until the alarm sounds. This verifies the electronic circuitry, horn, and battery are working correctly.
5.2 クリーニング
Clean your alarm at least once a month. Use a soft brush attachment on your vacuum cleaner to remove dust and debris from the openings around the perimeter of the alarm. Do not use cleaning solvents or spray directly on the unit.
5.3 寿命表示
The smoke detector has a 10-year operational life. At the end of its life, the unit will begin to chirp two times every 30 seconds. This indicates that the alarm needs to be replaced immediately. The alarm will not detect smoke in this condition. To silence the end-of-life chirps for up to 3 days, press the Test/Hush button. This feature is temporary and the unit must be replaced.
6。 トラブルシューティング
If your smoke detector is not functioning as expected, refer to the following common issues and solutions.
6.1 Nuisance Alarms
If the alarm sounds due to cooking smoke, steam, or other non-emergency conditions, press the Test/Hush button to temporarily silence it. Ensure the alarm is not placed too close to kitchens, bathrooms, or other sources of steam/smoke. Regular cleaning can also prevent false alarms caused by dust buildup.
6.2 Chirping Sounds
Refer to the "LED Indicators and Alarm Signals" table in Section 4.2 for a detailed explanation of chirping patterns. Most chirps indicate a low battery, a dirty sensor, or that the unit has reached its end-of-life and requires replacement.
6.3 テスト中にアラームが鳴らない
If the alarm does not sound when the Test/Hush button is pressed, ensure the unit is receiving 120V AC power and the battery is activated. If the issue persists, the unit may be faulty and requires replacement.
7. 仕様
Detailed technical specifications for the Kidde i12010S Smoke Detector.
| 特徴 | 仕様 |
|---|---|
| モデル番号 | i12010S |
| 電源 | 120 Volts AC, 60Hz Hardwired |
| バッテリーバックアップ | 密封型10年リチウム電池(付属) |
| センサータイプ | イオン化 |
| アラームの音量 | 10フィートで85デシベル |
| 動作湿度 | 最大95%の相対湿度、結露しないこと |
| 製品寸法 | 奥行き1.75インチ x 幅5.5インチ x 高さ5.5インチ |
| アイテム重量 | 7.2オンス |
| 相互接続 | 最大24台のキッドデバイス |
| 認定資格 | UL Certified, Meets UL 217, NFPA72, NFPA101 |

Image 7.1: Dimensions of the Kidde i12010S Smoke Detector.
8. 保証とサポート
8.1 限定保証
The Kidde i12010S Smoke Detector comes with a 10-year limited manufacturer's warranty. This warranty covers defects in materials and workmanship under normal use and service. Please retain your proof of purchase for warranty claims.
8.2 カスタマーサポート
For technical assistance, warranty service, or to return a unit for repair, please contact Kidde Safety directly. Do not attempt to repair the unit yourself.
キッドセーフティ
1016 Corporate Park Dr.
メバネ、ノースカロライナ州 27302
電話: (800) 880-5768