Cloudray PS06ZMLCD

Cloudray LCD Display Current Meter for MYJG 100W/150W Power Supplies

Model: PS06ZMLCD

導入

This manual provides instructions for the installation, operation, and maintenance of the Cloudray LCD Display Current Meter, model PS06ZMLCD. This device is designed to enhance the functionality of compatible MYJG series CO₂ laser power supplies by providing real-time current display and, for specific models, current adjustment capabilities. Please read this manual thoroughly before installation and operation to ensure proper use and optimal performance.

製品終了view

The Cloudray LCD Display Current Meter is an external module that connects to compatible MYJG laser power supplies. It features an LCD screen to show current output, water protection status, and laser signal status. For MYJG 100W and 150W power supplies, it also allows for current adjustment via an integrated potentiometer. For MYJG 50W, 60W, and 80W power supplies, it functions as a display-only unit.

パッケージ内容

  • 1 x Cloudray LCD Display Current Meter
  • 1 x Ethernet Cable (for connection)

製品構成

Cloudray LCD Display Current Meter and Ethernet Cable

画像1: The Cloudray LCD Display Current Meter and its included Ethernet cable. The meter features a display screen, a rotary knob for adjustment, and a test button.

Dimensions of Cloudray LCD Display Current Meter

画像2: Detailed dimensions of the Cloudray LCD Display Current Meter, showing its length, width, and depth for installation planning.

セットアップ手順

  1. 電源を切る: Ensure the laser machine and its power supply are completely powered off and disconnected from the main power source before proceeding with installation.
  2. Locate Network Port: Identify the network port (RJ45) on your MYJG series laser power supply. This port is typically labeled and located on the side or back of the power supply unit.
  3. イーサネットケーブルを接続します: Connect one end of the provided Ethernet cable to the network port on the MYJG power supply.
  4. ディスプレイメーターを接続する: Connect the other end of the Ethernet cable to the corresponding network port on the back of the Cloudray LCD Display Current Meter.
  5. 取り付け(オプション): The display meter can be panel-mounted into a suitable enclosure or control panel. Refer to the product dimensions for precise cutout requirements.
  6. Power Supply Switch (for MYJG 100W/150W): For MYJG 100W and 150W power supplies, locate the small switch or potentiometer on the power supply unit itself.
    • If this switch is turned to the , the LCD screen's built-in trimmer potentiometer will be active, allowing you to adjust the current directly from the display.
    • If it is turned to the , the LCD screen will display normally, but its potentiometer will not function for current adjustment.
  7. 電源オン: Once all connections are secure, reconnect the laser machine to the main power source and power it on. The LCD display should illuminate and show current status.
Connecting Cloudray LCD Display Current Meter to MYJG Power Supply

画像3: Illustration of the Ethernet cable connection between the Cloudray LCD Display Current Meter and a compatible MYJG series laser power supply.

Location of potentiometer switch on MYJG power supply

画像4: 閉じる view of the potentiometer switch on the MYJG power supply, which enables or disables current adjustment from the LCD meter.

操作手順

After successful installation and power-on, the LCD display will show real-time operational data.

情報を表示

Cloudray LCD Display showing current output and status

画像5: The Cloudray LCD Display showing "Current output" in milliamperes (mA), "Water protection" status (ON/OFF), and "Laser signal" status (ON/OFF).

  • 現在の出力: Displays the real-time current (in milliamperes, mA) being supplied to the laser tube.
  • 防水: Indicates the status of the water protection system. "ON" means the water protection is active and functioning; "OFF" means it is not active or there is an issue.
  • Laser Signal: Shows whether a laser signal is being sent to the power supply. "ON" indicates a signal is present; "OFF" indicates no signal.
Cloudray LCD Display status indicators

画像6: Various states of the Cloudray LCD Display, illustrating different combinations of current output, water protection, and laser signal statuses.

Current Adjustment (MYJG 100W/150W only)

If your MYJG power supply is 100W or 150W and the internal switch was set to the right during setup, you can adjust the laser current using the rotary knob on the display meter.

  • ロータリーノブ: Turn the knob clockwise to increase the current output and counter-clockwise to decrease it. Observe the "Current output" value on the LCD screen as you adjust.
  • テストボタン: Press the "TEST" button to momentarily activate the laser at the set current. This is useful for testing the laser output without initiating a full job.

注記: For MYJG 50W, 60W, and 80W power supplies, the rotary knob on the display meter will not adjust the current. It will only function as a display unit.

メンテナンス

The Cloudray LCD Display Current Meter requires minimal maintenance. Follow these guidelines to ensure its longevity and accurate performance:

  • クリーニング: 画面を軽く拭いて、asin柔らかく乾いた布で拭いてください。ディスプレイや仕上げに損傷を与える可能性のある研磨剤入りの洗剤や溶剤の使用は避けてください。
  • 接続: Periodically check the Ethernet cable connection to ensure it is secure and free from damage. A loose connection can lead to intermittent readings or loss of functionality.
  • 環境: Operate the device within its specified environmental conditions (temperature, humidity) to prevent damage.

トラブルシューティング

If you encounter issues with your Cloudray LCD Display Current Meter, refer to the following troubleshooting steps:

問題考えられる原因解決
Display does not light up or shows no information.
  • No power to the MYJG power supply.
  • Loose or incorrect Ethernet cable connection.
  • Incompatible power supply model.
  • Ensure the laser machine and MYJG power supply are powered on.
  • Check that the Ethernet cable is securely connected at both ends.
  • Verify your MYJG power supply is compatible (MYJG 50W-150W series).
Current adjustment knob does not work.
  • Power supply is MYJG 50W, 60W, or 80W (display-only models).
  • Internal switch on MYJG 100W/150W power supply is set to "left" (potentiometer disabled).
  • Confirm your power supply model. Adjustment is only available for MYJG 100W/150W.
  • For MYJG 100W/150W, ensure the internal switch on the power supply is set to the right to enable the display's potentiometer.
Inaccurate or fluctuating current readings.
  • 接続が緩んでいます。
  • 電気的干渉。
  • すべてのケーブル接続を確認してください。
  • Ensure proper grounding of the laser system.

仕様

特徴詳細
モデル名PS06ZMLCD
ブランドクラウドレイ
対応デバイスMYJG 50W-150W CO₂ Laser Power Supplies
Functionality (MYJG 50W/60W/80W)Current display only
Functionality (MYJG 100W/150W)Current display and adjustment
製品寸法(長さ x 幅 x 高さ)6.8 x 3.7 x 4.5インチ(約173 x 94 x 114 mm)
アイテム重量8.8オンス(約0.25kg)
接続タイプイーサネット(RJ45)

保証とサポート

For warranty information and technical support, please refer to the documentation provided with your original purchase or contact Cloudray customer service directly. Keep your purchase receipt as proof of purchase for any warranty claims.

You can typically find support contact details on the official Cloudray webサイトまたは製品を購入した小売店を通じて購入できます。

© 2024 Cloudray. 無断複写・転載を禁じます。

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.