1. はじめに
The RIGOL DS1054Z is a 4-channel digital oscilloscope offering a 50MHz bandwidth, 1GSa/s real-time sampling rate, and a 24Mpt record length. It incorporates RIGOL's innovative UltraVision technology to provide advanced display and analysis capabilities. This manual provides essential information for the proper setup, operation, and maintenance of your DS1054Z oscilloscope.
2. 主な特徴
- 50 MHz bandwidth with 4 analog channels.
- Up to 1 GSa/s real-time sampリンレート。
- Standard 12 Mpts memory depth, upgradeable to 24 Mpts.
- Innovative UltraVision technology for enhanced signal visibility.
- Waveform capture rate up to 30,000 wfms/s.
- 7-inch WVGA (800x480) display with multi-level intensity grading.
- All-in-one signal debugging and emulation.
- Accelerated analysis and debugging for I2C, RS232, and SPI designs.
3.製品オーバーview
このセクションでは、視覚的かつ機能的な概要を説明します。view of the RIGOL DS1054Z Digital Oscilloscope.

図1: 前面 view of the RIGOL DS1054Z Digital Oscilloscope, showing the display, control panel, and input channels.

図2:背面 view of the RIGOL DS1054Z Digital Oscilloscope, displaying power input, USB, LAN, and auxiliary output ports.
4. セットアップ
- 開梱: Carefully remove the oscilloscope and all accessories from the packaging. Verify that all included components (power cord, USB cable, 4x 150MHz probes) are present.
- 電源接続: Connect the provided power cord to the AC input on the rear panel of the oscilloscope and then to a suitable AC power outlet (100 V~240 V).
- 電源オン: Press the power button located on the front panel to turn on the device. The display will illuminate, and the system will initiate its startup sequence.
- プローブ接続: Connect the 150MHz probes to the desired input channels (CH1-CH4) on the front panel. Ensure a secure connection.
- Initial Probe Compensation: Before taking measurements, it is recommended to perform probe compensation to ensure accurate readings. Refer to the detailed user guide for specific instructions on probe compensation.
5. 操作手順
This section covers basic operational procedures for the DS1054Z oscilloscope.
5.1 基本的な波形取得
- 接続信号: 測定したい信号源にプローブを接続します。
- チャンネルを選択: 対応するチャンネルボタン(例: 1 位) をクリックしてチャネルを有効にします。
- 自動セットアップ: For a quick display of the waveform, press the オート button. The oscilloscope will automatically adjust vertical, horizontal, and trigger settings.
- 手動調整: Use the vertical scale (V/div) and position knobs for each channel, and the horizontal scale (s/div) and position knobs to fine-tune the waveform display.
5.2 トリガー機能
The DS1054Z offers various trigger types to stabilize and capture specific events.
- エッジトリガー: Triggers on a rising or falling edge of a signal.
- Pulse Width Trigger: 指定された幅のパルスでトリガーします。
- スロープトリガー: 特定の立ち上がり時間または立ち下がり時間を持つ信号をトリガーします。
- ビデオトリガー: 標準ビデオ信号でトリガーします。
- Pattern Trigger: Triggers when a specific logic pattern is met across multiple channels.
- Duration Trigger: Triggers on events lasting a specified duration.
To access trigger settings, press the トリガーメニュー button and use the soft keys and multi-function knob to configure the desired trigger type and parameters.

Figure 3: Oscilloscope display illustrating various expanded functions and trigger options, including memory depth settings.
5.3 Waveform Record and Playback
The DS1054Z allows for recording and playback of waveforms, which is useful for capturing transient events or analyzing long signal sequences.
- Access Record Function: Navigate to the waveform record menu (refer to the full user manual for exact menu path).
- Configure Recording: Set the desired record length and other parameters.
- 記録の開始/停止: Initiate recording to capture waveforms. Stop recording when the desired data is acquired.
- 再生: 再生コントロールを使用して、view the recorded waveforms.

Figure 4: Oscilloscope display showing the interface for waveform recording and playback, including controls for starting, stopping, and reviewing captured data.
6. 仕様
| パラメータ | 仕様 |
|---|---|
| アナログ帯域幅 | 50 MHz |
| チャンネル | 4つのアナログチャンネル |
| 最大リアルタイムSampルレート | 1 GSa/s (1 channel), 500 MSa/s (2 channels), 250 MSa/s (3/4 channels) |
| 最大メモリ深度 | 12 Mpts (1 channel), 6 Mpts (2 channels), 3 Mpts (3/4 channels); upgradeable |
| 最大波形キャプチャレート | 30,000 wfms/秒 |
| Vertical Input Impedance | 1MΩ±2% |
| Vertical Input Range | 1 mV/div~10 V/div |
| 水平時間基準範囲 | 5 ns/div to 50 s/div |
| Standard Trigger Functions | Edge, Pulse Width, Slope, Video, Pattern, Duration |
| Standard Bus Decode | Parallel Bus |
| インターフェース | USB Host & Device, LAN (LXI), AUX Output (Trigger Out, Pass/Fail) |
| 画面 | 7.0-inch WVGA (800x480) TFT LCD, 64 intensity grading levels |
| 電源 | AC: 100 V~240 V |
| 寸法(幅x高さx奥行き) | 313.1mm×160.8mm×122.4mm |
| 重さ | 約3.2kg |
| 付属アクセサリ | Power cord, USB cable, 4x 150MHz probes |
7. メンテナンス
- クリーニング: オシロスコープの外装は、定期的に柔らかく乾いた布で拭いてください。頑固な汚れには、軽く湿らせた布を使用してください。ampened with water or a mild, non-abrasive cleaner. Avoid using harsh chemicals or solvents.
- 換気: 過熱を防ぐため、デバイスの通気口が塞がれていないことを確認してください。
- ストレージ: When not in use for extended periods, store the oscilloscope in a clean, dry environment, away from direct sunlight and extreme temperatures.
- プローブのお手入れ: Handle probes carefully. Avoid bending or stressing the cables excessively. Store probes properly to prevent damage to the tips and connectors.
8。 トラブルシューティング
This section addresses common issues you might encounter with your oscilloscope.
8.1 電源投入後に画面が表示されない
- 電源コードがオシロスコープと電源コンセントの両方にしっかりと接続されているかどうかを確認します。
- 電源コンセントが機能していることを確認します。
- 電源ボタンが完全に押されていることを確認してください。
8.2 不安定な波形
- Adjust the trigger level to a stable point on the waveform.
- Select an appropriate trigger type for the signal being measured (e.g., Edge trigger for periodic signals).
- Check the probe connection and ensure it is properly compensated.
- Verify the input signal's amplitude and frequency are within the oscilloscope's specifications.
8.3 信号が表示されない
- Ensure the input channel is enabled (its corresponding button is lit).
- Check the probe connection to the signal source and the oscilloscope.
- Adjust the vertical scale (V/div) to a more sensitive setting.
- を押す オート ボタンを押すと、オシロスコープが自動的に信号を検出します。
9. 保証とサポート
9.1 保証情報
The RIGOL DS1054Z main unit comes with a standard 3年間保証 from the date of purchase when bought through Amazon. Accessories such as modules, probes, and batteries are covered by a 1年間保証. This warranty covers operational defects confirmed by RIGOL Japan. Parallel import products are not eligible for warranty or free support from RIGOL Japan.
In case of a suspected malfunction, after our company confirms that the event is a malfunction, we will provide a replacement with the same product or repair service, or other appropriate response as determined by our company.
9.2 Initial Defect Exchange Policy
Returns are accepted within 14 days of product arrival for initial defects. Return shipping costs for reasons other than operational defects are borne by the purchaser. Questions regarding operational defects or usage are accepted via Amazon email.
9.3 修理と校正
For repair or calibration services, please contact a domestic authorized RIGOL dealer.
9.4 追加のリソースとサポート