TCI E0882-25G

製品取扱説明書

製品: Ethyl Isobutyrylacetate

モデル: E0882-25G

ブランド: TCI America

1.製品オーバーview

This manual provides essential information for the safe and effective handling, storage, and use of Ethyl Isobutyrylacetate (E0882-25G) supplied by TCI America.

Ethyl Isobutyrylacetate is an organic reagent primarily intended for laboratory research and development applications. It is a carbonyl compound and a key building block in organic chemistry.

Product packaging for Ethyl Isobutyrylacetate

Image: Typical packaging for TCI America chemical reagents, including Ethyl Isobutyrylacetate.

2. 安全情報と注意事項

WARNING: This product is for laboratory research use only. It is not intended for human or animal use, or as a component in food, drugs, medical devices, cosmetics, or pesticides.

Always consult the Safety Data Sheet (SDS) for comprehensive safety information before handling this chemical. Key precautions include:

  • Wear appropriate Personal Protective Equipment (PPE), including safety goggles, gloves, and a lab coat.
  • Work in a well-ventilated area or under a fume hood to avoid inhalation of vapors.
  • Avoid contact with skin, eyes, and clothing. In case of contact, rinse immediately with plenty of water and seek medical advice.
  • 飲み込まないでください。飲み込んだ場合は、直ちに医師の診察を受けてください。
  • 使用しないときは容器をしっかりと閉めてください。
  • 互換性のない材料から離して保管してください。

3. 製品仕様

Detailed chemical and physical properties of Ethyl Isobutyrylacetate (E0882-25G):

財産価値
化学名Ethyl Isobutyrylacetate
CAS番号7152-15-0
MDL番号MFCD00009198
Purity (GC)>95.0%
分子式C10H12O6
分子量158.20
沸点90℃
同義語Isobutyrylacetic Acid Ethyl Ester, Ethyl 4-Methyl-3-oxovalerate, 4-Methyl-3-oxovaleric Acid Ethyl Ester
Chemical structure of Ethyl Isobutyrylacetate

Image: Chemical structure of Ethyl Isobutyrylacetate (C8H14O3).

4. 取り扱いと保管

4.1. Receiving and Initial Inspection

Upon receipt, inspect the packaging for any signs of damage or leakage. Ensure the product label matches the order and the container is sealed. Store immediately according to recommended conditions.

4.2. 保管条件

Store Ethyl Isobutyrylacetate at a temperature range of 15-25 °C (room temperature). Keep the container tightly closed in a dry, well-ventilated place. Protect from light and moisture. Ensure storage area is secure and accessible only to authorized personnel.

4.3. General Handling Guidelines

  • Handle with care to prevent spills.
  • 清潔で乾燥したガラス器具や機器を使用してください。
  • Avoid cross-contamination with other chemicals.
  • Always return unused material to its original container if possible, or dispose of properly.

5. 使用上のガイドライン

Ethyl Isobutyrylacetate is used as an organic reagent in various chemical synthesis and research applications. Specific usage protocols will depend on the intended experimental design.

5.1. アプリケーション

This chemical is categorized under Organic Reagents and Carbonyl Compounds [Non-Heterocyclic Building Blocks]. It serves as a versatile building block for synthesizing more complex organic molecules.

5.2. Purity Considerations

The product is supplied with a purity of >95.0% (GC). For sensitive applications, users should consider verifying purity before use. Impurities may affect reaction outcomes.

6. Emergency Procedures and Disposal

6.1. Spill Response

In case of a spill, immediately evacuate the area if necessary and ensure proper ventilation. Wear appropriate PPE. Absorb the spilled material with an inert absorbent (e.g., sand, vermiculite, diatomaceous earth). Collect in a suitable container for disposal. Do not allow product to enter drains or watercourses.

6.2. First Aid

  • 吸入: Move to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen. Get medical attention.
  • 皮膚接触: Wash off with soap and plenty of water. Consult a physician if irritation develops.
  • アイコンタクト: Rinse thoroughly with plenty of water for at least 15 minutes and consult a physician.
  • 摂取: Do NOT induce vomiting. Never give anything by mouth to an unconscious person. Rinse mouth with water. Consult a physician.

6.3. 廃棄物処理

Dispose of contents and container in accordance with local, regional, national, and international regulations. Chemical waste should be handled by licensed waste disposal contractors.

7. 免責事項

TCI America's products are intended primarily for laboratory use and, unless otherwise indicated on TCI America's invoice, other writings, or on product labels, are not to be used for other purposes, including, but not limited to, human or animal use, or a component in, a food, drug, or medical device (including in vitro diagnostic reagents) or cosmetics as defined in the Federal Food, Drug and Cosmetic Act, as amended, nor as a pesticide as defined in the Federal Insecticide, Fungicide and Rodenticide Act, as amended. Buyer acknowledges that the products purchased hereunder have not been tested by TCI America for safety and efficacy in a food, drug, cosmetic or pesticide unless otherwise stated by TCI America in writing furnished to Buyer. Buyer expressly represents and warrants to TCI America that Buyer will properly test, use, manufacture and market any products purchased from TCI America. For full disclaimer, see TCI Terms and conditions.

8. サポートとお問い合わせ

For technical support, product inquiries, or to access the Safety Data Sheet (SDS), please visit the official TCI America website or contact their customer service. TCI America is a division of Tokyo Chemical Industry, offering a wide range of high-quality organic reagents for research and development.

Assortment of TCI America chemical products

Image: A selection of chemical products from TCI America.

詳しい情報と連絡先については、 TCI Store on Amazon または公式の企業 webサイト。

© 2025 TCI America. 無断複写・転載を禁じます。

This manual is subject to revision. Please refer to the latest version available from TCI America.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.