PASCO scientific PS-2002
PASCO PS-2002 Xplorer GLX Graphing Logger User Manual
モデル: PS-2002
1. はじめに
This manual provides comprehensive instructions for the operation, maintenance, and troubleshooting of the PASCO PS-2002 Xplorer GLX Graphing Logger. The Xplorer GLX is a versatile data acquisition device designed for scientific experimentation and analysis, capable of functioning both as a standalone unit and as a computer interface.

図1: フロント view of the PASCO PS-2002 Xplorer GLX Graphing Logger. This device features a large LCD screen for data display, function buttons (F1-F4) for quick access, a central navigation pad, a numeric keypad for data entry, and a power button at the bottom. The casing is a translucent blue with green accents on the primary control buttons.
2. 主な特徴
The PASCO PS-2002 Xplorer GLX offers a range of features designed for robust data logging and analysis:
- 統合センサー: Includes 2 temperature sensors, a sound sensor, and a voltageセンサー。
- Universal Sensor Ports: Four dedicated PASPORT sensor ports for compatibility with over 60 PASPORT sensors.
- ハイSampリンレート: Capable of a maximum 50,000 Hz sampling rate for precise data capture.
- 内部ストレージ: Equipped with 12 MB of built-in flash memory for data storage.
- 接続性: Two USB ports for connecting to computers, external storage, or peripherals like a mouse and keyboard.
- 力: Powered by a rechargeable 1700 mAH NiMH Battery.
- 画面: Large backlit LCD for clear visibility in various lighting conditions.
- スタンドアロン操作: Functions independently for data collection, analysis, annotation, storage, and printing without a computer.
- コンピューターインターフェース: Can connect to a computer to utilize PASCO Capstone software for advanced analysis.
3. セットアップと初期使用
3.1 開梱とコンポーネント
開梱したら、すべてのコンポーネントが揃っていることを確認してください。
- PASCO PS-2002 Xplorer GLX unit
- Rechargeable 1700 mAH NiMH Battery (pre-installed or separate)
- USBケーブル(充電およびコンピュータ接続用)
- 電源アダプタ(含まれている場合)
3.2 バッテリーの充電
- Connect the USB cable to the GLX unit's USB port.
- USB ケーブルのもう一方の端を電源アダプタまたはコンピュータの USB ポートに接続します。
- Allow the unit to charge fully before first use. The charging indicator will provide status.
3.3 電源のオン/オフ
- 電源を入れるには、 力 button (usually located at the bottom of the keypad) until the screen illuminates.
- 電源を切るには、 を長押しします 力 シャットダウンプロンプトが表示されるまでボタンを押し続け、確認します。
3.4 センサーの接続
The GLX features four universal PASPORT sensor ports. To connect a sensor:
- Align the sensor's connector with one of the PASPORT ports on the GLX.
- Gently push the sensor into the port until it clicks into place.
- The GLX should automatically detect the connected sensor.
4. 操作手順
4.1 ナビゲーション
The Xplorer GLX uses an icon-based operating system. Navigation is primarily done using the central directional pad and function buttons (F1-F4).
- 方向パッド: Use the up, down, left, and right arrows to move between menu items or data points. The center button typically acts as a selection or confirmation button.
- 機能ボタン(F1~F4): These buttons correspond to on-screen labels and provide quick access to specific functions or menus.
- ESCボタン: Used to go back to the previous screen or cancel an operation.
- テンキー: For entering numerical values or text (using multi-press for letters).
4.2 Data Collection
- 測定単位を選択: From the main menu, navigate to the desired measurement setup (e.g., Graph, Digits, Table).
- 設定を構成する: を調整するampling rate, duration, and trigger conditions as needed for your experiment.
- Start Collection: を押す 遊ぶ button (often a green triangle icon) to begin data collection.
- Stop Collection: を押す 停止 button (often a square icon) to end data collection.
4.3 Data Analysis and Review
The GLX allows for basic on-device data analysis:
- グラフ View: Display collected data as a graph. Use navigation buttons to zoom or pan.
- 統計: Access statistical tools (mean, min, max, standard deviation) for selected data ranges.
- Linear Curve Fits: Perform basic linear regression on graphical data.
- 注釈: Add text notes or recorded voice messages to data points or entire runs.
4.4コンピューターへの接続
For advanced analysis and data management, connect the GLX to a computer:
- Ensure PASCO Capstone software is installed on your computer.
- Connect the GLX to your computer using a USB cable.
- The GLX will be recognized as a device within Capstone, allowing data transfer and real-time monitoring.
5. メンテナンス
5.1 クリーニング
To maintain the device's condition:
- 本体の外側を柔らかい布で拭いてください。amp 布。
- 研磨剤や溶剤は使用しないでください。
- Ensure no liquid enters the sensor ports or USB ports.
5.2バッテリーケア
- Recharge the NiMH battery regularly to maintain its lifespan.
- バッテリーを頻繁に完全に放電することは避けてください。
- If storing the unit for an extended period, ensure the battery is partially charged (around 50%).
5.3 ストレージ
Store the Xplorer GLX in a cool, dry place, away from direct sunlight and extreme temperatures.
6。 トラブルシューティング
| 問題 | 考えられる原因 | 解決 |
|---|---|---|
| ユニットの電源が入りません。 | バッテリーが放電しました。 | Connect the unit to a power source using the USB cable and allow it to charge. |
| Sensor not detected. | Sensor not properly connected or faulty. | Ensure the sensor is firmly seated in the PASPORT port. Try a different port or sensor if available. |
| 画面が暗い、または判読できない。 | Backlight setting is low or environmental lighting is poor. | Adjust the backlight settings in the system menu. Move to a better-lit environment if necessary. |
| Data collection stops unexpectedly. | Low battery or insufficient memory. | Charge the battery. Check available memory and delete old data if needed. |
7. 仕様
| 特徴 | 詳細 |
|---|---|
| モデル番号 | PS-2002 |
| ブランド | パスコ科学 |
| 寸法(長さ×幅×高さ) | 9 x 3.8 x 1.9インチ |
| 重さ | 1.29 ポンド |
| センサーポート | 4 PASPORT sensor ports |
| 内蔵センサー | 2 Temperature, Sound, Voltage |
| Sampling Rate (Max) | 50,000Hz |
| 内部メモリ | 12MBのフラッシュメモリ |
| 接続性 | USBポート2個 |
| 電源 | Rechargeable 1700 mAH NiMH Battery |
| 表示タイプ | バックライト付きLCD |
| 材料 | プラスチック |
| お手入れ方法 | ワイプクリーン |
8.サポートと保証
For technical support, product inquiries, or warranty information, please contact PASCO scientific directly. Refer to the official PASCO scientific web最新の連絡先情報と保証ポリシーについては、こちらのサイトをご覧ください。
メーカー: パスコ
発売日: 19年2017月XNUMX日
Ask a question about this manual
Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.