DAC HCA001

DAC Patient Alert & Personal Alarm

Model: HCA001 User Manual

1. はじめに

This manual provides detailed instructions for the proper setup, operation, and maintenance of your DAC Patient Alert & Personal Alarm, Model HCA001. This device is designed to serve two primary functions: to alert caregivers when a patient moves from a bed or chair, and to function as a personal security alarm for immediate protection.

Please read these instructions carefully before using the device to ensure safe and effective operation.

DAC Patient Alert & Personal Alarm in original packaging

Image 1: The DAC Patient Alert & Personal Alarm, Model HCA001, shown in its original retail packaging. The packaging highlights its multi-purpose functionality as both a patient alert and a personal alarm.

2. 安全情報

  • バッテリーの安全性: Always use the specified 17-volt battery. Do not mix old and new batteries, or different types of batteries. Dispose of used batteries responsibly according to local regulations.
  • 窒息の危険: Keep small parts, such as the battery and clips, out of reach of children and individuals who may ingest them.
  • アラーム音量: The alarm produces a loud 110dB sound. Avoid prolonged exposure to the alarm at close range to prevent potential hearing discomfort.
  • 使用目的: This device is an alert system and not a substitute for direct supervision or professional medical care.
  • 水への露出: 本製品は防水仕様ではありません。水や過度の湿気にさらさないでください。

3. パッケージ内容

パッケージにすべてのアイテムが含まれていることを確認してください。

  • DAC Patient Alert & Personal Alarm Unit (HCA001)
  • 48-inch Adjustable Cord with Alligator Clip and Snap Clip
  • 8-inch Accessory Strap with Buckle
  • Alarm Mount with Clip or Double-Sided Tape (pre-attached or separate)

Note: A 17-volt battery is required and is not included in the package.

4. セットアップ

4.1 バッテリーの取り付け

  1. アラームユニットの背面にある電池ボックスを見つけます。
  2. 電池カバーを慎重に開けます。
  3. Insert one 17-volt battery, ensuring the polarity (+/-) matches the indicators inside the compartment.
  4. 電池カバーをしっかりと閉じてください。
Back of DAC Patient Alert & Personal Alarm packaging showing battery information

Image 2: The back of the DAC Patient Alert & Personal Alarm packaging, illustrating details such as battery requirements (17 Volt Battery Required, Not Included) and warranty information.

4.2取り付けオプション

The alarm unit offers several versatile mounting options:

  • 統合されたクリップ: The alarm unit features a built-in clip on its back, allowing it to be easily attached to clothing, a belt, or other thin edges.
  • 両面テープ: For more permanent placement on flat surfaces like walls, bed frames, or furniture, use the provided double-sided tape on the alarm mount. Ensure the surface is clean and dry before application.
  • Accessory Strap: The 8-inch accessory strap with a buckle can be used to secure the alarm to larger objects or limbs, providing a flexible attachment solution.

5. 操作手順

5.1 Patient Alert Mode

This mode is designed to alert caregivers when a patient moves or attempts to exit a bed or chair.

  1. Attach the Cord: Securely attach the 48-inch adjustable cord to the patient's clothing or a bedsheet using the alligator clip or snap clip.
  2. Connect to Alarm: Insert the other end of the cord (the pin) into the designated jack on the alarm unit.
  3. Position the Alarm: Place the alarm unit in a location where the caregiver can easily hear it, such as near the bed, chair, or on a bedside table. Ensure the cord has enough slack for comfortable patient movement but will pull out if the patient attempts to leave the monitored area.
  4. アクティベーション: When the patient moves sufficiently to pull the cord's pin out of the alarm unit, the 110dB alarm will sound.
  5. アラームのリセット: To silence the alarm, re-insert the pin firmly into the alarm unit's jack.

5.2 Personal Alarm Mode

This mode provides a loud alarm for personal protection in emergency situations.

  1. Carry the Alarm: Keep the alarm unit readily accessible, for example, clipped to your belt, bag, or held in your hand.
  2. アクティベーション: In an emergency, pull the cord's pin completely out of the alarm unit. The 110dB alarm will sound immediately.
  3. アラームのリセット: To silence the alarm, re-insert the pin firmly into the alarm unit's jack.

6. メンテナンス

6.1 クリーニング

To clean the alarm unit, wipe it with a soft, dry cloth. Do not use abrasive cleaners, solvents, or immerse the unit in water.

6.2 電池の交換

When the alarm sound becomes weak or fails to activate, it is time to replace the 17-volt battery. Follow the battery installation steps outlined in Section 4.1.

7。 トラブルシューティング

  • アラームが鳴らない:
    • Check if the 17-volt battery is installed correctly and is not depleted. Replace if necessary.
    • Ensure the pin is fully removed from the jack when attempting to activate the alarm.
  • Alarm sounds weakly:
    • The battery may be low. Replace the 17-volt battery.
  • False alarms in Patient Alert Mode:
    • Ensure the cord is securely attached to the patient's clothing and the alarm unit.
    • Adjust the cord length to provide sufficient slack for normal movement without accidental dislodgement.

8. 仕様

  • モデル: HCA001
  • 電源: 17ボルト電池1個(別売)
  • アラーム音量: 110デシベル
  • コードの長さ: 48インチ(調節可能)
  • Accessory Strap Length: 8インチ
  • 機能: Patient Alert, Personal Protection Alarm

9. 保証情報

This DAC Patient Alert & Personal Alarm (Model HCA001) is guaranteed against defects in materials and workmanship in normal use for a period of 6か月 from the date of purchase. This warranty is valid only if the alarm has not been altered or modified, or if a repair attempt has not been made by unauthorized personnel.

保証請求のために購入証明書を保管してください。

10. お問い合わせとサポート

技術サポート、保証請求、その他のお問い合わせについては、下記までご連絡ください。

DAC Technologies of America Inc

カスタマーサポート:1-800-216-1515

© 2023 DAC Technologies of America Inc. All rights reserved.