Codelocks KL1060

Codelocks KL1060 NetCode ロッカーロック ユーザーマニュアル

モデル: KL1060

導入

This manual provides detailed instructions for the installation, operation, and maintenance of the Codelocks KL1060 NetCode Locker Lock. The KL1060 is designed to provide secure, temporary access to lockers and cabinets using time-sensitive codes generated via the web-based NetCode Portal.

製品終了view

The Codelocks KL1060 is a digital keypad lock that offers advanced access control features, particularly suited for remote locker and cabinet applications, as well as rental scenarios. Its primary feature is the NetCode system, which allows for the generation of time-sensitive access codes.

  • ネットコード Web-Based Code Generation: Create and manage temporary access codes online.
  • 10ボタンキーパッド: For manual code entry.
  • Multiple Code Levels: Includes Master, Sub-Master, User, and Technician codes.
  • 機能: Supports Private, Public, and NetCode operating modes.
  • 電池駆動: Operates on 2 x AAA batteries, providing approximately 15,000 operations.
  • 耐久性: IP55 rated when used with a door gasket (sold separately).
  • 材料: Constructed from metal for durability.
Codelocks KL1060 NetCode Locker Lock installed on a wooden cabinet door

図1: Codelocks KL1060 NetCode Locker Lock. This image shows the silver-grey keypad lock installed on a light brown wooden cabinet door, with the "NETCODE 1060" logo visible on the door.

セットアップとインストール

The KL1060 is designed for straightforward installation, either as a retrofit for existing cam locks or for new installations.

Pre-Installation Steps: NetCode Activation

  1. Create Online Account: Before physical installation, create an account on the official Codelocks NetCode Portal.
  2. レジスターロック: Register your specific KL1060 lock on the NetCode Portal. This step activates the NetCode functionality.
  3. Generate Initial Codes: Use the portal to generate initial time-sensitive codes as needed.

物理的なインストール

The KL1060 is a quick retrofit for standard keyed cam locks. Installation typically takes only a few minutes.

  1. 既存のロックを削除: If retrofitting, carefully remove the existing cam lock from the locker or cabinet door.
  2. 取り付け穴の準備: The KL1060 requires a hole for the spindle and an additional top fixing point.
    • For retrofits, ensure the existing cam lock hole is compatible and drill the additional top fixing hole if necessary.
    • For new installations, drill the main spindle hole and the top fixing hole according to the provided template (not included in this description, refer to product packaging for template).
  3. Install KL1060: Position the KL1060 lock body onto the door, aligning the spindle and fixing points.
  4. 安全なロック: Secure the lock using the provided fasteners. Ensure it is firmly attached and does not wobble.
  5. バッテリーの挿入: Install the 2 x AAA batteries into the designated battery compartment.

操作手順

The KL1060 offers various code levels and operating modes for flexible access control.

Code Levels

  • 8-Digit Master Code: Used for programming and managing all other codes. This code should be kept confidential.
  • 8-Digit Sub-Master Code: Provides access to certain programming functions and can open the lock.
  • 4-Digit User Codes: Standard codes for daily access by users.
  • 6-Digit Technician Code: For maintenance or service personnel, often with specific time restrictions.
  • 12-Digit NetCode: Time-sensitive codes generated via the NetCode Portal for temporary access.

NetCode Functionality

The NetCode system allows for remote generation and management of temporary access codes.

  1. Access NetCode Portal: Log in to your Codelocks NetCode Portal account from any internet-enabled device.
  2. Generate NetCode:
    • For long durations, create a NetCode that is valid between a specified start and end date.
    • For short durations (up to one day), create a NetCode valid from a specific date and time.
  3. Distribute NetCode: Send the generated NetCode to the intended user via email or SMS.
  4. ユーザー アクセス: The user enters the 12-digit NetCode on the KL1060 keypad during the valid timeframe to unlock the cabinet or locker.

Operating Modes (Private / Public / NetCode)

The KL1060 can be configured to operate in different modes:

  • Private Function: A single, fixed user code is used repeatedly. Ideal for personal lockers.
  • Public Function: Users enter a code to lock the unit, which is then cleared after opening, allowing a new user to set their own code. Ideal for shared lockers.
  • NetCode Function: Utilizes the time-sensitive codes generated via the NetCode Portal.

Refer to the full programming guide (available from Codelocks) for detailed instructions on how to switch between these operating modes and program specific codes.

メンテナンス

Regular maintenance ensures the longevity and reliable operation of your KL1060 lock.

バッテリー交換

  • The KL1060 operates on 2 x AAA batteries.
  • The lock provides approximately 15,000 operations per set of batteries.
  • When battery power is low, the lock will typically provide a visual or audible indicator.
  • 電池を交換するには:
    1. Locate the battery compartment, usually on the inside of the lock unit.
    2. コンパートメントカバーを開きます。
    3. 古い単4電池を取り外します。
    4. Insert new 2 x AAA alkaline batteries, ensuring correct polarity.
    5. 電池カバーをしっかりと閉じてください。

クリーニング

キーパッドとロック本体を柔らかくて清潔な布で拭いてください。amp 布で拭いてください。研磨剤入りの洗剤や溶剤は、仕上げや電子部品を傷める可能性があるため、使用しないでください。

トラブルシューティング

If you encounter issues with your KL1060 lock, refer to the following common troubleshooting steps.

問題考えられる原因解決
ロックはコード入力に反応しません。
  • 入力されたコードが間違っています。
  • 電池残量が少なくなっています。
  • Lock malfunction.
  • 正しいコードが入力されていることを確認してください。
  • 電池を新しい単4電池に交換してください。
  • Attempt a 9V battery override (see below).
NetCode not working.
  • NetCode expired or not yet active.
  • Incorrect NetCode entered.
  • Lock not properly registered on NetCode Portal.
  • Verify the NetCode's validity period on the NetCode Portal.
  • Re-enter the 12-digit NetCode carefully.
  • Check lock registration status on the NetCode Portal.
ロックを回したり操作したりすることが困難です。
  • Misalignment during installation.
  • Obstruction in the locking mechanism.
  • Check installation for proper alignment and adjust if necessary.
  • Inspect for any physical obstructions.

Emergency 9V Battery Override

In cases of complete battery failure where the lock does not respond, a 9V battery can sometimes be used to temporarily power the lock for emergency access. Locate the 9V battery contacts on the lock (refer to the product diagram or Codelocks documentation for exact location). Press a 9V battery firmly against these contacts while simultaneously entering your valid code. This should provide enough power to operate the lock once.

注記: If the 9V battery override does not work, or if the lock continues to malfunction after battery replacement, contact Codelocks technical support.

仕様

特徴詳細
モデル番号KL1060
ロックタイプKeypad, Digital
材料金属
シルバーグレー
電源単2電池XNUMX本(付属)
バッテリー寿命約15,000件の手術
IP 定格IP55 (when used with door gasket)
推奨用途Remote lockers/cabinets, rental applications
アイテム重量15.2オンス
パッケージ寸法6 x 2.5 x 1.6インチ

保証とサポート

For specific warranty information, please refer to the documentation included with your product or visit the official Codelocks website. If you require technical assistance, have questions about NetCode functionality, or need to report a product issue, please contact Codelocks customer support directly.

Codelocks Contact Information: ぜひご覧ください www.codelocks.com for the most up-to-date support contact details, including phone numbers and email addresses for your region.

© 2023 Codelocks. All rights reserved. Information subject to change without notice.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.