1. はじめに
The APC Back-UPS BX1400UI is an Uninterruptible Power Supply (UPS) designed to protect your electronic equipment from power outages, surges, and spikes. Featuring Line Interactive Technology and Automatic Voltage Regulation (AVR), this unit provides reliable battery backup and surge protection for connected devices. It includes six IEC 320 C13 outlets, a USB interface for communication, and data line protection.

図1: 前面 view of the APC Back-UPS BX1400UI.
2. 重要な安全情報
- 電気による危険: このユニットには高容量tage components. Do not attempt to open the UPS casing, especially when connected to power. Refer all servicing to qualified personnel.
- 直接接続: Always connect the UPS directly to a wall outlet. Do not use surge protectors, extension cords, or power strips with the UPS input.
- 換気: UPSの周囲に十分な換気を確保してください。通気口を塞がないでください。
- 最初の臭い: A new unit may emit a distinct odor, often described as similar to burnt plastic. This is normal and typically dissipates after a few weeks of continuous operation in a well-ventilated area. It is not indicative of a malfunction.
- バッテリー交換: User-performed battery replacement during the warranty period will void the product warranty. Refer to the Maintenance section for details.
3. パッケージ内容
パッケージに次のアイテムが含まれていることを確認してください。
- APC Back-UPS BX1400UI Unit
- Two (2) IEC-C13 to IEC-C14 power cables (for connecting devices to the UPS)
- ユーザーマニュアル(このドキュメント)
注記: The input power cable (for connecting the UPS to the wall outlet) and the USB communication cable are typically 含まれません and must be purchased separately if needed.
4. セットアップ
4.1. Unpacking and Battery Connection
- UPS をパッケージから慎重に取り出します。
- Locate the yellow battery connector on the rear panel of the UPS. This connector is typically disconnected for safe transport.
- Push the yellow battery connector firmly into its socket until it clicks into place. This activates the UPS battery circuits.
4.2。 電源への接続
- Connect the UPS to a grounded 230V AC wall outlet using an appropriate IEC-320 C14 input power cable (not included).
- Ensure the connection is direct to the wall outlet. Do not use surge protectors or extension cords.
- Allow the UPS to charge for at least 10 hours before connecting critical equipment to ensure full battery runtime.
4.3. 機器の接続
The BX1400UI features six IEC 320 C13 outlets for connecting your devices.
- バッテリーバックアップおよびサージ保護コンセント: All six IEC-C13 outlets provide both battery backup and surge protection. Connect your computer, monitor, and other critical electronics to these outlets.
- データライン保護: The rear panel includes RJ-11 ports labeled "DSL/Modem/Fax/Phone" for protecting your telephone or DSL line from surges. These ports are not suitable for Ethernet network connections.
- USBインターフェース: Connect a USB Type B cable (not included) from the UPS to your computer for communication and to enable shutdown software functionality.

Figure 2: Rear panel connections of the APC Back-UPS BX1400UI.
5. 操作手順
5.1.電源のオン/オフ
- 電源を入れるには: Press and hold the power button on the front panel until you hear a short beep. The UPS will perform a self-test, and the 'On Line' LED will illuminate green.
- 電源を切るには: UPS の電源が切れるまで電源ボタンを押し続けます。
5.2.LEDインジケーター
The front panel features LED indicators to show the UPS status:
- オンライン(緑色のLED): Indicates the UPS is operating on utility power and providing power to connected equipment.
- バッテリー使用時(黄色のLED): Indicates the UPS is operating on battery power during a power outage or brownout. A humming noise is normal during battery operation.
- バッテリーを交換(赤色のLED): Indicates the battery needs to be replaced.
- 過負荷(赤色LED): Indicates that the connected equipment exceeds the UPS's capacity. Disconnect non-essential equipment immediately.
5.3.自動巻tage規制(AVR)
UPSはマイナーボリュームを自動的に修正しますtage fluctuations (sags and surges) without switching to battery power, thus preserving battery life. If voltage fluctuations exceed the AVR's correction range, the UPS will switch to battery power.
6. 主な特徴
- Line Interactive Technology: Provides stable power by regulating voltage without constantly switching to battery.
- 自動巻tage規制(AVR): Corrects minor voltagバッテリー電源を使わずに変動します。
- バッテリーバックアップ: Supplies power to connected equipment during outages。
- サージ保護: Protects connected devices from damaging power surges and spikes.
- 6 IEC 320 C13 Outlets: Standard outlets for computer equipment.
- USBインターフェース: Enables communication with a computer for monitoring and controlled shutdown.
- データライン保護: Safeguards telephone/DSL lines from surges.
7. ソフトウェアの使用
The APC Back-UPS BX1400UI supports USB Human Interface Device (HID) class specifications, allowing it to be recognized by most operating systems without special drivers.
7.1. APC PowerChute Personal Edition (Windows)
For advanced monitoring and management on Windows systems, download the APC PowerChute Personal Edition software from the official APC webサイト。このソフトウェアを使用すると、次のことが可能になります。
- Monitor UPS status, power consumption, and battery charge.
- 長時間電源オフ時にコンピュータを自動的にシャットダウンする設定tages。
- Adjust UPS settings, such as alarm behavior (e.g., disable the beeper during battery operation).
- Perform self-tests to ensure proper UPS functionality.
7.2. Linux Support (apcupsd / NUT)
For Linux environments, the UPS can be managed using `apcupsd` or Network UPS Tools (NUT). These tools provide similar monitoring and shutdown capabilities. Refer to the documentation for `apcupsd` or NUT for configuration details, typically involving specifying `UPSCABLE usb` and `UPSTYPE usb` for `apcupsd`, or using the `usbhid-ups` driver for NUT.
8. メンテナンス
8.1. バッテリーの交換
The APC Back-UPS BX1400UI uses two 12V 7.2Ah sealed lead-acid batteries. The recommended replacement battery pack is APC RBC113.
- During Warranty: If the unit is still under its 2-year warranty, battery replacement must be performed by Schneider Electric IT (SEIT) customer service. User-performed battery replacement during the warranty period will automatically void the warranty.
- After Warranty: After the warranty period, batteries can be replaced by the user. However, due to the presence of high voltage components even when disconnected, it is highly recommended that this operation be performed by specialized personnel. If you choose to replace the batteries yourself, exercise extreme caution.
- 手続き終了view (for experienced users only): Disconnect the UPS from all power sources and connected equipment. Disconnect the yellow battery connector. Remove the rear panel screws, then the front panel (which is snap-fitted), and additional screws. Carefully access the battery compartment. Note the orientation and wiring of the existing batteries (taking photos is recommended) to ensure correct installation of the new batteries.
8.2.サーキットブレーカーのリセット
In case of an overload, the UPS may trip its circuit breaker. To reset, disconnect some equipment from the UPS, then press the circuit breaker button located on the rear panel (refer to Figure 2).
9。 トラブルシューティング
| 問題 | 考えられる原因 | 解決 |
|---|---|---|
| UPSがオンになりません。 | Battery connector disconnected; No input power. | Ensure yellow battery connector is fully inserted. Verify UPS is plugged into a live wall outlet. |
| Initial strong odor. | New unit manufacturing residue. | This is normal. Ensure adequate ventilation. Odor will dissipate over time (typically a few weeks). |
| UPS emits a humming noise. | Operating on battery power; Normal electrical noise. | Humming is normal when on battery. If persistent and loud on utility power, ensure proper ventilation and check for loose connections. |
| 'Overload' LED is lit. | 接続されている機器が多すぎます。 | Disconnect non-essential equipment. Press the circuit breaker reset button on the rear panel. |
| 'Replace Battery' LED is lit. | バッテリーの寿命が近づいています。 | Contact APC support or a qualified technician for battery replacement. Refer to Section 8.1. |
| バッテリー駆動時間が短い。 | バッテリーが完全に充電されていない、バッテリーの寿命が近づいている、負荷が大きすぎる。 | Ensure initial 10-hour charge. Reduce connected load. Consider battery replacement if old. |
For more detailed troubleshooting, refer to the complete user manual available on the APC webサイト。
10. 仕様
| 特徴 | 仕様 |
|---|---|
| モデル | BX1400UI |
| 容量 (VA/ワット) | 1400VA / 700W |
| 入力ボリュームtage | 230V 交流 |
| 入力周波数 | 50Hz |
| 出力巻tage | 230V AC (simulated sine wave on battery) |
| 出力コンセント | 6 x IEC 320 C13(バッテリーバックアップおよびサージ保護) |
| サージ保護定格 | 273ジュール |
| 電池のタイプ | 密閉型鉛蓄電池 |
| バッテリー構成 | 2 x 12V 7.2Ah |
| 通常の充電時間 | 8時間(90%の容量まで) |
| Runtime (at 700W load) | 約1分 |
| Runtime (at 100W load) | 約60分 |
| 寸法(高さ×幅×奥行き) | 21.5 cm x 13 cm x 33.6 cm |
| 重さ | 4.7キロ |
| インターフェイスポート | USB Type B, RJ-11 (Data Line Protection) |

Figure 3: Typical runtime graph for APC Back-UPS 1400VA.
11. 保証とサポート
11.1. 製品保証
The APC Back-UPS BX1400UI comes with a 2年間の限定保証 ご購入日から1年間有効です。本保証は、通常の使用状況における材料および製造上の欠陥を対象としています。保証請求の際は、購入証明書を保管してください。
重要: Unauthorized opening of the unit or user-performed battery replacement during the warranty period will void the warranty.
11.2. テクニカルサポート
For technical assistance, troubleshooting, or warranty service, please contact APC by Schneider Electric customer support. Visit the official APC website for contact information specific to your region, including phone numbers and online support resources.