Xpelair GX6

Xpelair GX6 Extractor Fan User Manual

Model: GX6 (90800AW)

1. はじめに

The Xpelair GX6 is a standard 150mm (6 inch) axial extractor fan designed for efficient ventilation in large bathrooms, domestic kitchens, utility rooms, and small commercial offices. This fan is suitable for direct ventilation to the outside and can be mounted on walls, windows, or panels using the provided universal mounting kit. It features silent shutter operation, an aesthetically pleasing and easy-to-clean cover, and an integrated finger guard. The design prioritizes ease of maintenance. All Xpelair GX6 fans comply with Building Regulations Mechanical Ventilation for Kitchens.

2. 安全情報

  • 設置、メンテナンス、清掃を行う前に必ず電源を切ってください。
  • 設置は、国の配線規制および地域の建築基準に従って、資格のある電気技師が行う必要があります。
  • Ensure the fan is correctly earthed as it is rated as a Class 1 appliance.
  • Do not operate the fan if any part is damaged or if the casing は開いています。
  • Keep children and unauthorized persons away from the fan during operation and maintenance.
  • Ensure that the air supply to the fan is not obstructed.

3. セットアップとインストール

The Xpelair GX6 fan is designed for versatile mounting on walls, windows, or panels. A universal mounting kit is included. Ensure the chosen location allows for direct ventilation to the outside and provides adequate space for installation and maintenance.

3.1.壁への取り付け

For wall mounting, a hole diameter of 203mm is typically required. Refer to the diagram below for visual guidance on component placement and assembly.

Xpelair GX6 Wall Mounting Diagram

図1: Diagram illustrating the components and setup for wall mounting the Xpelair GX6 fan. Note the required hole diameter of 203mm.

3.2.窓の取り付け

For window mounting, a hole diameter of 184mm is typically required. The diagram below provides a visual reference for window installation.

Xpelair GX6 Window Mounting Diagram

図2: Diagram illustrating the components and setup for window mounting the Xpelair GX6 fan. Note the required hole diameter of 184mm.

3.3. Detailed Dimensions

Consult the detailed dimensions diagram for precise measurements required for cutting and fitting. This ensures proper integration into your chosen mounting surface.

Xpelair GX6 Detailed Dimensions Diagram

図3: Technical drawing showing detailed dimensions (A-K) for the Xpelair GX6 fan, including hole diameters for installation.

3.4。 電気接続

All electrical wiring must be performed by a qualified electrician. Ensure the power supply is isolated before commencing any wiring. The fan is designed to be operated via the lighting circuit, which also controls the integral run-on timer.

4. 操作手順

The Xpelair GX6 is a single-speed extract fan designed for straightforward operation.

  • アクティベーション: The fan is typically activated by switching on the room's lighting circuit.
  • Run-on Timer: An integral run-on timer allows the fan to continue operating for a set period after the light is switched off. This timer is adjustable from 2 to 20 minutes.
  • Electro-Thermal Shutter: The fan incorporates an integral electro-thermal shutter that opens when the fan is active and closes when it is off, preventing drafts and heat loss.
  • リモートコントロール: Some models may include a remote control for additional operational flexibility. Refer to specific product packaging or supplementary documentation for remote control functionality.

5. メンテナンス

Regular maintenance ensures optimal performance and longevity of your Xpelair GX6 fan. The fan features an easy-to-clean cover and a design focused on simple maintenance.

5.1. ファンの清掃

  1. 電源を切る: Always ensure the power supply to the fan is completely disconnected at the mains before attempting any cleaning.
  2. カバーを取り外す: Carefully unclip or unscrew the front cover of the fan.
  3. 表面をきれいにする: Wipe the exterior and interior surfaces of the cover and the fan body with a soft, damp cloth. A mild detergent can be used if necessary. Avoid abrasive cleaners.
  4. ブレードのクリーニング: Gently clean the fan blades to remove any dust or debris. Be careful not to bend or damage the blades.
  5. 組み立て直す: Once all parts are dry, carefully reattach the cover, ensuring it is securely fastened.
Xpelair GX6 Exploded View

図4: 爆発した view of the Xpelair GX6 fan, showing its main components for assembly and maintenance reference.

6。 トラブルシューティング

If you encounter issues with your Xpelair GX6 fan, refer to the following troubleshooting guide:

  • ファンが動作していない:
    • 電源が接続され、オンになっているかどうかを確認します。
    • Verify that the lighting circuit (if used for activation) is functioning correctly.
    • Ensure all wiring connections are secure (consult a qualified electrician if unsure).
  • 過度の騒音:
    • Disconnect power and check for any obstructions (e.g., debris) in the fan blades or grille.
    • Ensure the fan is securely mounted and all screws are tightened. Loose components can cause vibration.
  • Poor Extraction Performance:
    • Check if the fan grille or ducting is blocked by dust or debris.
    • Ensure the electro-thermal shutter is opening fully when the fan is active.
    • Verify that the installation hole diameter is correct for optimal airflow.

If problems persist after following these steps, contact a qualified electrician or Xpelair customer support.

7. 仕様

Key technical specifications for the Xpelair GX6 extractor fan:

特徴価値
モデルGX6 (90800AW)
ファンタイプ軸抽出ファン
Extract Performance (m³/h)266
Extract Performance (l/s)74
Sound Pressure Level (dB(A) @3m)37
Electrical Power Rating30W
Hole Diameter (Window Mounting)184mm
Hole Diameter (Wall Mounting)203mm
重さ1.9 キロ
速度の数1
コントローラータイプLighting Circuit / Remote (optional)
材料プラスチック
Xpelair GX6 Specifications Table Image

図5: Image displaying key specifications for the Xpelair GX6 fan, including air flow, sound level, and power rating.

8. 保証

The Xpelair GX6 extractor fan comes with a 3年間の保証 from the date of purchase. This warranty covers defects in materials and workmanship under normal use. Please retain your proof of purchase for any warranty claims. The warranty does not cover damage caused by improper installation, misuse, or unauthorized repairs.

9. サポート

For further assistance, technical support, or to inquire about replacement parts, please contact Xpelair customer service. Refer to the official Xpelair web最新の連絡先情報については、当社のサイトまたは製品パッケージをご覧ください。

  • オンラインリソース: Visit the official Xpelair webFAQ、製品登録、追加のサポート ドキュメントについては、こちらのサイトをご覧ください。
  • 連絡先: Refer to your product's packaging or the Xpelair website for phone numbers and email addresses for customer support in your region.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.