導入
This manual provides instructions for the Sonic Alert SB300SS Large Digital Alarm Clock. This device is designed to provide reliable and effective alarm functions, including a powerful bed shaker and extra-loud audio alarm, suitable for heavy sleepers and individuals with hearing impairments. Please read this manual thoroughly before operating the device.
箱の中身
- ソニックアラート SB300SS 目覚まし時計
- Power Cord (AC Adapter)
- ベッドシェーカー
製品終了view

フロント View: Shows the large digital display, integrated speakers, and the Sonic Alert logo. The top features a 5-level dimmer switch.

戻る View: Displays the Tone and Volume control knobs, Time/Alarm Set/Min/Hour buttons, vibrator input port, and the 9V battery backup compartment.

側 View: Features the alarm mode switch with options for VIB/BUZZ (vibration and audio), VIB (vibration only), BUZZ (audio only), and OFF.

使用中で: The alarm clock on a nightstand with the bed shaker placed under a pillow, illustrating its primary function for waking heavy sleepers.
特徴
- 超大音量アラーム: Unique 113 decibel alarm with adjustable tone and volume control.
- 強力なベッドシェイカー: Includes a 12-volt bed shaker for silent or combined vibration alerts.
- 大型デジタルディスプレイ: 1.8-inch display for easy readability.
- 5段階調光器: 快適なディスプレイの明るさ調整 viewどのような光条件でも使用できます。
- Dual Time Format: 12 時間表示と 24 時間表示の両方をサポートします。
- Adjustable Snooze: User-selectable snooze duration from 1 to 30 minutes.
- Adjustable Alarm Duration: User-selectable alarm duration from 1 to 59 minutes.
- アラームとベッドシェーカーのテストモード: Allows testing of alarm functions at any time.
- バッテリーバックアップ: 9V battery backup (battery not included) maintains time and alarm settings for up to one week during power outages。
- グリーン電力技術: Uses 60% less energy for improved efficiency.
- デュアル電源機能: Compatible with standard travel adapters for versatile use.
設定
- 電源接続: Plug the AC adapter into a standard wall outlet and connect it to the alarm clock's power input.
- バッテリーバックアップのインストール: Open the battery compartment on the back of the clock. Insert one 9V battery (not included), ensuring correct polarity. This battery provides backup for time and alarm settings during power interruptions.
- ベッドシェーカー接続: Plug the bed shaker's cord into the "VIBRATOR" port on the back of the alarm clock. Place the bed shaker under your pillow or mattress for optimal vibration.
- 設定時間: Press and hold the "TIME" button. While holding, press the "HOUR" button to adjust the hour and the "MIN" button to adjust the minutes. Release the "TIME" button when finished. Note the PM indicator for 12-hour format.
操作手順
- アラームの設定:
- Press and hold the "AL.SET" button.
- While holding "AL.SET", press the "HOUR" button to set the alarm hour and the "MIN" button to set the alarm minutes.
- Release the "AL.SET" button when the desired alarm time is set.
- Adjusting Alarm Mode: Use the "VIB/BUZZ" switch on the side of the clock to select your preferred alarm mode:
- バイブ/バズ: ベッドシェーカーと可聴アラームの両方を作動させます。
- VIB: ベッドシェイカーのみを作動させます。
- バズ: 可聴アラームのみを作動させます。
- OFF: アラームを無効にします。
- Adjusting Tone and Volume: Use the "TONE" and "VOLUME" control knobs on the back of the clock to customize the audible alarm sound. Turn the "VOLUME" knob to adjust loudness and the "TONE" knob to adjust pitch.
- スヌーズの使用: When the alarm sounds, press the large "SNOOZE" bar on top of the clock to temporarily silence the alarm. The snooze duration can be set from 1 to 30 minutes.
- ディスプレイの明るさの調整: Use the "5 LEVEL DIMMER" switch located on the top of the clock to adjust the brightness of the digital display to your preference.
- Changing Time Format (12/24 Hour): Press the "HOUR" button while the time is displayed to toggle between 12-hour and 24-hour formats.
- Using Test Mode: To test the alarm and bed shaker functions, press and hold the "TEST" button (if available, or refer to specific model instructions for test mode activation).
メンテナンス
- クリーニング: Wipe the clock with a soft, dry cloth. Do not use liquid cleaners or abrasive materials.
- バッテリー交換: Replace the 9V backup battery annually or when the battery low indicator appears to ensure continuous backup functionality.
- ストレージ: If storing the clock for an extended period, remove the 9V backup battery to prevent leakage.
トラブルシューティング
| 問題 | 解決 |
|---|---|
| アラームが鳴らない/振動しない。 | Check the alarm mode switch (VIB/BUZZ, VIB, BUZZ). Ensure the volume knob is not set to OFF. Verify the alarm time is set correctly. |
| ディスプレイが空白または暗い。 | Ensure the power cord is securely plugged in. Adjust the 5-level dimmer switch. If using battery backup, the display will not light up to conserve power. |
| 電源を切ると時間/アラーム設定が失われますtage. | Check and replace the 9V backup battery. Ensure the battery is installed correctly. |
| ベッドシェイカーが振動しません。 | Ensure the bed shaker is securely plugged into the vibrator port. Check the alarm mode switch is set to VIB or VIB/BUZZ. |
仕様
- ブランド: ソニックアラート
- モデル: SB300SS
- 色: 銀
- 表示タイプ: デジタル
- 電源: コード式電気(ACアダプター)
- バックアップバッテリー: 9V x 1(別売)
- 製品寸法: 幅10.25インチ x 高さ4.25インチ
- 商品の重量: 1.45 ポンド
- 材料: プラスチック
- 特別な機能: Vibrating Alarm, Loud Alarm, Adjustable Brightness, Snooze
製品ビデオ
このビデオでは、view of the Sonic Alert SB300SS Alarm Clock, demonstrating its features and functionality, including the extra-loud alarm, bed shaker, and various controls.
保証とサポート
The Sonic Alert SB300SS Alarm Clock comes with a one-year Sonic Alert blast-proof warranty. For technical support, troubleshooting assistance, or warranty claims, please contact Sonic Alert customer service. You can find contact information on the official Sonic Alert webサイトまたは製品のパッケージを通じて入手できます。
オプションの保護プランを購入できます:
- 2年間の保護プラン
- 3年間の保護プラン
- Complete Protect (monthly plan covering multiple purchases)